Hussmann CW2UGE Specifications

B
F
E
A
D
H
G
H
C
C
P/N_0518268_A
Note: Changed items have been underlined
.
F
AN ASSEMBLIES AND THERMOSTATS
A. 7W Parent Fan Assembly (1)
0058698 Fan Motor, Standard (MO.4410102) 0142780 Fan Blade (FB.0142780)
embossing toward motor
B. 12W End Compartment Fan Assembly (2)
0477655 Fan Motor, Standard (MO.4410546) 0377253 Fan Blade (FB.4780616)
embossing away from motor
C. 0398558 Standard Non-Adjustable (3)
Defrost Thermostat (CT.4481088)
D. 0144732 Optional Adjustable (4)
Refrigeration Thermostat (CT.4481085)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
E. Ballast, Electronic
0466234 2 lamps (BA.4480823) (5) 0376410 3 lamps (BA.4480901) (5)
F. Ballast, Electronic (End Compartment) (6)
0135966 1 lamp (BA.4480883)
G. 0039764 Lamp Starter (EP.4481081) (7)
H. Fluorescent Lamp (8)
Replace with like fixtures
CW2UGE
Technical Data Sheet
P/N 0518268_A
NSF
®
Certified
November 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
2 of 8 CW2UGE Technical Data Sheet
90 in. 138 in.
General
(A) Case Length (without ends or partitions) 89 (2261) 137 (3480)
(Each flat end adds 1 1/
2 in. [38 mm] to lineup; each contour end adds 5 in. [127 mm].
Maximum O/S dimension of case front to rear (includes bumper) 81 1/2 (2070) 81 1/2 (2070)
(B) End of case to end of compartment 48 1/
4 (1226) 96
1
/
4 (1478)
Length of the end compartment 40
3
/4 (1035) 40 3/4 (1035) Front of splashguard to O/S edge of base rail 8 1/2 (216) 8 1/2 (216) Front edge of case to O/S edge of base rail 12 5/
8 (321) 12
5
/
8 (321)
Rear of case to O/S edge of front base rail 68
7
/8 (1749) 68 7/8 (1749) Width of base rail 2 1/8 (54) 2 1/8 (54) Stub-up area between front base rail and splashguard 7 1/
4 (184) 7
1
/
4 (184)
Electrical Service
Note: Electrical Field Wiring connection point
Center of Electrical service to O/S edge of front base rail 7 (178) 7 (178) Right end of case to center of knockout 5 (127) 5 (127) Length of electrical raceway 32
5
/8 (829) 32 5/8 (829)
Waste Outlet
(C) LH end of case to the center of rear waste outlet 10 1/8 (257) 58 1/8 (1476)
Center of waste outlet to O/S edge of rear base rail 3 7/8 (98) 3 7/8 (98) Left end of case to center of front waste outlet 38 1/8 (968) 38 1/8 (968) Left edge of end compartment to center of waste outlet 32 (813) 32 (813) Rear edge of end compartment to center of waste outlet 38 5/8 (981) 38 5/8 (981)
Water Seal
Water seal length 11 (279) 11 (279) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (23)
Water seal outlet must clear front skid rail.
Refrigeration Outlet
RH & LH end of case to center of refrigeration outlets 5 5/8 (143) 5 5/8 (143) Center of refrigeration outlet to O/S edge of front base rail 1 1/8 (29) 1 1/8 (29)
A
C
40
3
/4
(1035)
B
CW2U90GE
C
L
Base Rail
Refrig. Outlet
Front
(See Note)
CW2U90XGE
5 5/8
(143)
32
(813)
38 5/8
(981)
38 1/8
(968)
5 (127)
Waste Outlet & Water Seal
81 1/2
(2070)
68 7/8
(1749)
12 5/8
(321)
8 1/2
(216)
1 1/8
(29)
3 7/8
(98)
7
(178)
29 1/2
(749)
28 1/4
(718)
Access Area
Water Seal
Unitized
Convertible Island
05-2003
Engineering
Plan Views
Dimensions shown as inches and (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
1
/2
Merchandiser Suction Line (in.) 1 1/8
Front of
Case
FAN
FAN
COIL COIL
C
L
16 in. Shelf
12 in. Shelf
25 5/8
(651)
24 1/8
(613)
32
(813)
6 3/8
(162)
48
(1219)
7
(178)
3 7/8
(98)
1 1/8
(29)
8 1/2
(216)
12 5/8
(321)
68 7/8
(1749)
81 1/2
(2070)
5
(127)
26
(660)
5 (127)
21
(533)
8 1/4 (210)
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
CW2U CW2U
90GE 138GE
Discharge Air (°F) 28 28 Evaporator Air (°F) 21 21 Unit Sizing (°F) 19 19
Btu/hr/case*
CW2U CW2U
90GE 138GE
Parallel 10,520 16,440 Conventional 11,660 18,220
*Optional energy efficient motors reduce the refrigeration load of : CW2U-90GE by 171 Btu/hr/case CW2U-138GE by 341 Btu/hr/case.
DEFROST DATA
CW2U CW2U
90GE 138GE
Frequency (hr) 66 Defrost Water (lb/day) 72 112
(± 15% based on case configuration and product
loading).
OFFTIME CW2U CW2U
90GE 138GE
Temp Term (°F) 48° 48° Failsafe (minutes) 45 45
E
LECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CW2U CW2U
90GE 138GE
CI/CO (Temp °F)* 17°/ 17°/
Indoor Unit Only, Pressure Defrost Termination (Temp °F)*48° 48°
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Estimated Charge (lb)**
CW2U-90GE 4.0
CW2U-138GE 6.3
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0518268_A 3 of 8
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown as inches and (mm).
Unitized Convertible Island, 2 Display Levels
Excel CW2UGE
Unitized Convertible Island
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
CW2UGE
Loading...