Hussmann C6X-LRE Specifications

B
G
F
D
E
C
A
D
E
P/N_0480223_E
C6X-LRE
Technical Data Sheet
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0463643 Fan Blade (FB.4780648)
12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0463643 Fan Blade (FB.4780648)
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
LIGHTED SHELVES NOT RECOMMENDED
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision G adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/
2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 45
1
/2 (1150) 45 1/2 (1150)
Back of case to front of splashguard 36 7/
8 (937) 36
7
/
8 (937)
Back of case to O/S edge of front skid rail 28
1
/4 (717) 28 1/4 (717) Width of skid rail 3 1/4 (82) 3 1/4 (82) RH end of case to outside edge of external support 5 1/
2 (140) 5
1
/
2 (140)
Distance between front skid rail and splashguard 7
1
/8 (181) 7 1/8 (181) Distance between edges of external supports Distance between edges of
external support and center support 42 1/2 (1070) 42 1/2 (1070)
Distance between edges of center supports NA 46 (1168)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/
4
(2140) 132
3
/
8
(3363) Back of case to center of stub up area 20 (508) 20 (508) Length of electrical wireway 26
1
/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/
8
(2289) 138
1
/
4
(3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84
1
/
4
(2140) 132
3
/
8
(3363) RH End of case to the center of RH waste outlet 12 (305) 12 (305) Back O/S of case to center of waste outlets 34
7
/8 (885) 34 7/8 (885)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 29 1/2 (749) 29 1/2 (749) RH end of case to center of refrigeration outlet 8 (203) 8 (203)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Splashguard
Waste Outlet
FRONT
3 3/8
(85)
12 1/8 (307)
Electrical Field Connection
5 1/2 (140)
13/8 (35)
4 1/4 (108)
8 (203)
Waste Outlet
B
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152 x 152)
Wireway
D
A
C
26 1/2
(673)
20
(508)
40 5/8
(1032)
44
(1118)
40 5/8
(1032)
34 7/8
(885)
36 7/8
(937)
29 3/8
(745)
45 1/2
(1155)
2 of 9
C6X-LRE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Rear Load
Dairy &
Delicatessen
09-2005
C6X-R
The
EXCEL
Rear Load Convertible model is not offered in 4-ft or 6-ft length.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
C6X-LRE
Discharge Air °F 32
Evaporator °F 21
Unit Sizing °F 19
Btu/hr/ft
— Unlit Shelves
‡‡
C6X-LRE Parallel Conventional
U
NLIT 1790 1960
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C6X-LRE
Frequency Hr 6
Defrost Water (lb/ft/day) 10.50
(± 15% based on case configuration and product loading).
OFFTIME C6X-LRE
Temp Term °F 48
Failsafe Minutes 35
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* C6X-LRE
14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** C6X-LRE
8 ft 3.2 lb 51 oz 1.5 kg
12 ft 4.5 lb 72 oz 2.0 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 9
P/N 0480223_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
3 (76)
34 7/8 (885)
4 1/8 (105)
43 7/8 (1113)
37 (940)
29 1/2 (749)
20 3/4
(527)
30 1/4
(768)
66 1/2
(1689)
42
(1065)
FAN
C6X-LRE
17 3/8
(442)
87 1/2
(2223)
7 1/4 (183)
19 3/4
(503)
3 5/8
(92)
COIL
Electrical
Case to Case
Connections
45 1/4
(1150)
60 1/2
(1536)
6
(152)
Refrigeration Outlet
3 1/8 (79)
45 1/2 (1150)
Impact
Excel
C6X-LRE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Rear Stockable Multi-deck, 6 Display Levels, Low Front
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...