Item Part # Description Wiring Item #
FAN ASSEMBLIES 4 Ft, 8 Ft & 12 Ft
A. 25W Standard Fan Assembly (1)
0501486 Fan Motor, Evaporator
(MO.4410702)
0501484 Fan Blade (FB.4780657) 25W Energy Efficient Fan Assembly (1) 0501485 Fan Motor, Evaporator
(MO.4410701)
0501484 Fan Blade (FB.4780657)
6 Ft Only
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
Item Part # Description Wiring Item #
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
H. LED Shelf Fixture (8)
Replace with like fixtures — See Page 5.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision G adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
2 of 10 C6X-LE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Convertible
09-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C6X
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/
8 (1229) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs NA 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/
4 (921) 60
1
/
4 (1530) 84
1
/
4 (2140) 132
3
/
8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C6X-LE Meat Produce Dairy
Discharge Air (°F) 29 29 31
Evaporator (°F) 21 21 24
Unit Sizing (°F) 19 19 22
Btu/hr/ft
— Unlit Shelves
‡‡
C6X-LE
‡‡
Parallel Conventional
M
EAT 1885 2000
P
RODUCE 1885 2000
D
AIRY 1790 1900
Optional energy efficient motors reduce the refrigeration load by 46 Btu/hr/ft (4 ft, 8 ft and 12 ft models), and 57 Btu/hr/ft (6 ft models).
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C6X-LE
Frequency Hr 4
Defrost Water (lb/ft/day) 10.50
(± 15% based on case configuration and product loading).
OFFTIME C6X-LE
Temp Term °F 48
Failsafe Minutes 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* C6X-LE
Meat Produce Dairy
14°F / 4°F 14°F / 4°F 17°F / 7°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** C6X-LE
4 ft 1.6 lb 26 oz 0.7 kg
6 ft 2.3 lb 37 oz 1.0 kg
8 ft 3.2 lb 51 oz 1.5 kg
12 ft 4.5 lb 72 oz 2.0 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 10
P/N 0473388_G
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
30 1/4
(768)
42
(1064)
60 1/2
(1537)
FAN
C O
I
L
C6X-LE
17 1/4
(438)
3 In. (77 mm)
Required
Air Gap
87 3/8
(2219)
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
26 1/4 (665)
Refrigeration Outlet
6
(152)
Electrical
Case to Case
Connections
17 1/8
(436)
67 1/8
(1704)
Dimensions shown as in. and (mm).
Multi-deck, 6 Display Levels, Low Front
Impact
Excel
C6X-LE
Meat, Produce, Dairy &
Delicatessen
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
4 of 10 C6X-LE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Impact
Excel
C6X-LE
Meat, Produce, Dairy & Delicatessen
Electrical Data
Amperes Watts
Evaporator Fan 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
120V 60Hz Standard 1.23 2.00 2.46 3.69 90 156 180 270 120V 50Hz Standard 1.33 2.20 2.66 3.99 103 168 206 309 230V 60Hz Export 0.66 1.00 1.32 1.98 100 156 200 300 230V 50Hz Export 0.76 1.12 1.52 2.28 114 168 228 342 120V 60Hz Energy Efficient 0.60 0.76 1.20 1.80 36 56 72 108 230V 60Hz Energy Efficient 0.30 0.40 0.60 0.90 36 56 72 108
Minimum Circuit Ampacity
120V 60Hz Standard 1.43 2.20 2.66 3.89 120V 50Hz Standard 1.53 2.40 2.86 4.19 230V 60Hz Export 0.86 1.20 1.52 2.18 230V 50Hz Export 0.96 1.32 1.72 2.48 120V 60Hz Energy Efficient 0.80 0.96 1.40 2.00 230V 60Hz Energy Efficient 0.50 0.60 0.80 1.10
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15
Standard Lighting (T-8 Fluorescent)
1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Optional Lighting (T-8 Fluorescent)
Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85 Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170 Additional 3 Row Canopy 0.77 1.53 1.53 2.31 89 177 177 255 1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85 1 Row of Shelves 0.26 0.51 0.51 0.77 30 59 59 85 2 Rows of Shelves 0.51 1.02 1.02 1.54 59 118 118 170 3 Rows of Shelves 0.77 1.53 1.53 2.31 89 177 177 255 4 Rows of Shelves 1.02 2.04 2.04 3.08 118 236 236 340 5 Rows of Shelves 1.28 2.55 2.55 3.85 148 295 295 425 6 Rows of Shelves 1.53 3.06 3.06 4.62 177 354 354 510
EcoShine Multi-deck — Normal (CRI) — 120VAC, 50/60Hz 2 Row Canopy (Front & Rear) 0.28 0.41 0.55 0.82 33 49 66 98
1 Row of Shelves 0.10 0.15 0.20 0.29 12 18 24 35 2 Rows of Shelves 0.20 0.29 0.39 0.58 24 35 47 70 3 Rows of Shelves 0.29 0.44 0.58 0.88 35 53 70 105 4 Rows of Shelves 0.39 0.58 0.78 1.17 47 70 93 140 5 Rows of Shelves 0.48 0.73 0.97 1.45 58 87 116 174 6 Rows of Shelves 0.58 0.88 1.17 1.74 70 105 140 209 7 Rows of Shelves 0.68 1.02 1.36 2.03 82 122 163 244
EcoShine Multi-deck — High CRI — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.32 0.47 0.63 0.93 38 56 75 112 1 Row of Shelves 0.12 0.18 0.23 0.35 14 21 28 42 2 Rows of Shelves 0.23 0.35 0.47 0.70 28 42 56 84 3 Rows of Shelves 0.35 0.53 0.70 1.05 42 63 84 126 4 Rows of Shelves 0.47 0.70 0.93 1.40 56 84 112 168 5 Rows of Shelves 0.58 0.88 1.17 1.75 70 105 140 210 6 Rows of Shelves 0.70 1.05 1.40 2.10 84 126 168 252 7 Rows of Shelves 0.82 1.23 1.63 2.45 98 147 196 294
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
4 ft 6 ft 8 ft 12 ft Number of Fans—25W 1 2 3 Number of Fans—7W 4
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
4 ft 6 ft 8 ft 12 ft (each)
lb (kg) 600 (272) 1000 (454) 1200 (544) 1900 (862) 100 (45)
4
Actual weights will vary according to optional kits included.
5 of 10P/N 0473388_G
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
C6X-LE
Meat, Produce, Dairy &
Delicatessen
Product Data
Recommended Usable Cube
2
(Cu Ft/Ft) 10.12 ft3 /ft (0.94 m3 /m)
AHRI Total Display Area
3
(Sq Ft/Ft) 5.25 ft2/ft (1.60 m2 /m)
Shelf Area 4(Sq Ft/Ft) 11.73 ft2/ft (3.58 m2 /m)
2
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
PARTS LIST (Continued from Page 1)
Note: Always*Bright lamps will be replaced with the latest generation of EcoShine lamps.
Item Part # Description
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. EcoShine LED Canopy Fixture (7)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
4441712 Front 36-inch 2900K HCRI 4441714 Front 36-inch 3500K HCRI 4441716 Front 36-inch 3500K 4441718 Front 36-inch 4100K
Item Part # Description
G.
(CONTINUED) EcoShine LED Canopy Fixture
4441713 Rear 36-inch 2900K HCRI 4441715 Rear 36-inch 3500K HCRI 4441717 Rear 36-inch 3500K 4441719 Rear 36-inch 4100K
H. EcoShine LED Shelf Fixture (8)
4441590 48-inch 2900K HCRI 4441591 48-inch 3500K HCRI 4441592 48-inch 3500K 4441593 48-inch 4100K
4441586 36-inch 2900K HCRI 4441587 36-inch 3500K HCRI 4441588 36-inch 3500K 4441589 36-inch 4100K
Defrost Termination Thermostat
Refrigeration
Thermostat
Dark Blue
3
To Condensing Unit
}
Light Blue
2
1, 2, 3 & 4 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
4 ft 6 ft 8 ft
12 ft
5
5
4
4
5
5
5
5
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
5
4
55
Connector
W
BK
BL
BL
R
BL
R
R
R
6 ft or 8 ft 10 ft or 12 ft4 ft
BK
6 ft or 8 ft 10 ft or 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
4 ft
5
4
55
Optional
Two Row
Canopy
W
BL
BL
R
BL
R
R
R
BK
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
C6X-LE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
6 of 10
Fan Wiring Offtime Defrost
Canopy Light Circuits — Fluorescent Fixtures
7 of 10P/N 0473388_G
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
5
R
BL
5
R
BL
BL
R
BL
R
5
R
BL
BL
4
5
5
5
BK
W
BL
BL
R
BL
BL
BL
W
R
W
R
BK
R
4
BK
BL
BL
BL
R
R
R
R
5
R
BL
5
R
BL
BL
R
BL
R
5
R
BL
BL
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
4 ft case
Connector
4
5
5
5
BK
W
Connector
6 ft or 8 ft case
12 ft case
BL
BL
R
BL
BL
BL
W
R
W
R
BK
R
4
BK
BL
BL
BL
R
R
R
R
5
R
BL
5
R
BL
BL
R
BL
R
5
R
BL
BL
4
5
5
5
BK
W
BL
BL
R
BL
BL
BL
W
R
W
R
BK
R
4
BK
BL
BL
BL
R
R
R
R
Optional Shelf Harness and Light Circuits for Six Rows of Shelves
Optional Shelf Lighting
Fluorescent Fixtures
C6X-LE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
8 of 10
Optional Canopy Lighting LED Fixtures
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
7
7
7
7
7
7
7
7
7
7
7
7
6
6
6
6
9 of 10P/N 0473388_G
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Optional Shelf Lighting
LED Fixtures
6 ft or 8 ft case
12 ft case
R
BL
R
BL
8
8
R
BL
6
BK
W
W
BL
R
G
Connector
Connector
BK
W
BK
W
BK
W
R
BL
R
BL
8
8
R
BL
R
BL
R
BL
8
8
R
BL
R
BL
BL
BL
(TYP)
Shelf Light
Plug & Receptacle
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves
R
R
BK
4 ft case
C6X-LE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
10 of 10
Optional Shelf Lighting LED Fixtures
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
8
8
8
8
8
8
8
R
BL
6
BK
BK
W
W
BL
R
G
4 ft case
6 ft or 8 ft case
12 ft case
(TYP)
Shelf Light
Plug & Receptacle
BK
Connector
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
8
8
8
8
8
8
8
R
BL
6
BK
BK
W
W
BL
R
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
8
8
8
8
8
8
8
R
BL
6
BK
BK
W
W
BL
R
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
W
Connector
Optional Shelf Harness and LED Light Circuits for 3, 4, 5, 6 & 7 Rows of Shelves
Loading...