Hussmann C6EPLUS Datasheet

C
C
D
D
D
A
B
P/N 0457234
C6EPLUS
Data Sheet Set
P/N 0457234
NSF
®
February 2004
Item Part # Description Wiring Item #
F
AN A
SSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0436427 Fan Blade
embossing toward motor
B. 0137880 Optional Adjustable (2)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. 0428648 Ballast, Electronic
2 lamps (3)
C. 0428649 Ballast, Electronic
3 lamps (3)
D. Fluorescent Lamp (4)
Replace with like fixtures
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Note: Changed items have been underlined
.
Merchandisers
®
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
Maximum O/S dimension of case back to front (includes bumper) 46 1/
4 (1174) 46
1
/
4 (1174)
Back of case to front of splashguard 38
5
/8 (981) 38 5/8 (981) Back of case to O/S edge of front skid rail 29 1/2 (749) 29 1/2 (749) Width of skid rail 4 1/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/2 (140) 5 1/2 (140) Distance between edges of external support and center support 40 5/8 (1032) 40 5/8 (1032) Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 7 (178) 7 (178)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 35 3/8 (899) 35 3/8 (899) Length of electrical raceway 34
5
/8 (878) 34 5/8 (878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 72
1
/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 1/2 (699) 27 1/2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
2 of 6 C6EP
LUS
Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy
01-2004
A
C6E C6LE C6GE C6HE
35 3/8
(899)
Electrical
72 1/4
(1835)
40 5/8
(1032)
7 (178)
B
4 1/4 (108)
27 1/2
(699)
Waste Outlet
Water Seal
(See note)
Front
40 5/8
(1032)
Refrigeration
Outlet
30 5/8
(778)
4 (102)
C
D
51/2 (140) 13/8 (35)
41/2 (114)
29 1/2
(749)
38 5/8
(981)
46 1/4
(1174)
3 of 6
P/N 0457234
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C O
I
L
C6EPLUS
FAN
4
3
/
8
(111)
Lighted Shelf
(Optional)
7 1/2
(191)
59
(1499)
45 5/8
(1159)
87
(2210)
22
(559)
66 5/8
(1693)
30 1/2
(775)
6 3/8 (162)
5 3/4
(146)
23
(584)
27 1/2 (699)
29 1/2 (749)
30 5/8 (778)
35 3/8 (899)
38 5/8 (981)
46 1/4 (1174)
7
(178)
6 1/8
(155)
18 1/4
(463)
Refrigeration Outlet
Impact C6EPLUS
Dairy
Multi-deck, 5 Display Levels
Dimensions shown as in. & (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
C6EP
LUS FOR D
AIRY U
NLIT LIT
Discharge Air °F 33 31
Evaporator °F 28 26
Unit Sizing °F 26 24
Btu/hr/ft* C6EP
LUS FOR DAIRY
UNLIT LIT
Parallel 1405 1475
Conventional 1465 1535
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 12
Defrost Water (lb/ft/day) 10.5
(± 15% based on case configuration and
product loading).
OFFTIME C6EPLUS FOR DAIRY
Time (minutes) 30
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO** C6EP
LUS FOR DAIRY
19°F / 9°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/
2
Liquid Line (in.)
3
/
8
Suction Line (in.)
7
/
8
Estimated Charge (lb)***
C6EP
LUS FOR DAIRY
8 ft 3.7 12 ft 5.1
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length (in.) Added to Lineup byEach End or Insulated Partition 1
1
/2
4 of 6 C6EP
LUS
Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact C6EPLUS
Dairy
Electrical Data
8 ft 12 ft
Number of Fans — 9W 4 6
Number of Fans — 9W (Export) 4 6
(Export: 230V 50 hz shown)
Amperes Watts
Merchandiser 8 ft 12 ft 8 ft 12 ft
Fans
Standard (120V 60Hz) 2.80 4.20 210 320
Energy Efficient (120V 60Hz) 1.52 2.28 100 150
Export (230V 50Hz) 1.52 2.28 228 342
Cycling Anti-sweat Heaters NA
Minimu Circuit Ampacity
With Standard Fans (120V 60Hz) 3.00 4.40
With Energy Efficient Fans (120V 60Hz) 1.72 2.48
With Export Fans (230V 50Hz) 1.72 2.48
Maximum Over Current Protection 20 20
Export (230V 50Hz) 15 15
Electric Defrost Heaters (208V 1ΦΦ) NA
Standard Lighting
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Row Rail 1.02 1.54 118 170
2 Rows Canopy 1.02 1.54 118 170
2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255
1 Row Ledge Lights 0.51 0.77 59 85
Optional Shelf Lighting
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
4 Rows of Shelves 2.04 3.08 236 340
5 Rows of Shelves 2.55 3.85 295 425
5 of 6
P/N 0457234
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Refrigeration
Thermostat
2
To Condensing Unit
}
Light Blue
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
4 & 6 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
BROWN BAND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
120 V Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
4
3
W
BL
R
4
BL
R
G
G
R
R
R
G
Shelf Lighting
G G
R
BL
4
BL
Connector
Connector
B
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
Light Circuits
Optional Lighting 2 Rows Canopy
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
= 120V POWER
= 120V NEUTRAL
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
C
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Lighting 3 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN BAND
B
B
W
4
BL
R
R
BL
BL
3
BL
R
R
BL
BL
3
4
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN BAND
B
BL
R
R
BL
BL
3
44
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN BAND
B
B
W
BL
R
R
BL
BL
3
BL
R
R
BL
BL
3
W
B
BL
R
R
BL
BL
3
R
4
R
R
R
R
R
44
4
4
4
4
4
4
4
4
4
4
4
6 of 6 C6EP
LUS
Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Loading...