Hussmann C5X-LEP Specifications

B
D
C
D
E
A
C
E
G
F
P/N_0479715_F
C5X-LEP
Technical Data Sheet
NSF
®
Certified
December 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
FAN ASSEMBLIES
8 Ft & 12 Ft
A. 25W Standard Fan Assembly (1)
0501486 Fan Motor, Evaporator
(MO.4410702)
0501484 Fan Blade (FB.4780657) 25W Energy Efficient Fan Assembly (1) 0501485 Fan Motor, Evaporator
(MO.4410701)
0501484 Fan Blade (FB.4780657)
6 Ft Only
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
Item Part # Description Wiring Item #
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
LAMPS. BALLASTS, LED FIXTURES AND POWER SUPPLY
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Fixture (6)
Replace with like fixtures
Note: Revision F adds 6-ft model. Other changes marked by underline or circle.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 9
C5X-LEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Convertible
09-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C5X
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60
1
/4 (1530) 84 1/4 (2140) 132 3/8 (3363) Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60 1/
4 (1530) 84
1
/
4 (2140) 132
3
/
8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
C5X-LEP DAIRY/DELI/PRODUCE
U
NLIT
LIT
Discharge Air (°F) 33 31
Evaporator (°F) 28 26
Unit Sizing (°F) 26 24
For red meat application, lower evaporator temperature and unit sizing 3°F. increase Btu 5%.
Btu/hr/ft‡— Unlit Shelves
‡‡
C5X-LEP‡‡Parallel Conventional
U
NLIT 1420 1490
Optional energy efficient motors reduce the
refrigeration load by 46 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C5X-LEP
Frequency Hr 12
Defrost Water (lb/ft/day) 10.5
(± 15% based on case configuration and product loading).
OFFTIME C5X-LEP
TIME (minutes) 30
E
LECTRIC OR GAS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO*
C5X-LEP D
AIRY/DELI/PRODUCE††
Temp (°F) 19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions. ††For red meat application, reduce low pressure backup control by 3°F.
Estimated Charge** C5X-LEP
6 ft 2.6 lb 42 oz 1.2 kg
8 ft 3.7 lb 59 oz 1.7 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approxi­mately half a pound.
3 of 9
P/N 0479715_F
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
30 1/4
(768)
61
(1549)
42
(1064)
54 7/8
(1393)
FAN
C O
I
L
C5X-LEP
17 1/4
(438)
3 In. (77 mm)
Required
Air Gap
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
26 1/4 (665)
Refrigeration Outlet
6
(152)
Electrical
Case to Case
Connections
17 1/8
(436)
81 3/4
(2077)
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels, Low Front
Impact
Excel
C5X-LEP
Dairy/Delicatessen/Produce
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.