Item Part # Description Wiring Item #
F
AN ASSEMBLIES
4 Ft, 8 Ft & 12 Ft
A. 25W Standard Fan Assembly (1)
0501486 Fan Motor, Evaporator
(MO.4410702)
0501484 Fan Blade (FB.4780657) 25W Energy Efficient Fan Assembly (1) 0501485 Fan Motor, Evaporator
(MO.4410701)
0501484 Fan Blade (FB.4780657)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
P/N_0480105_G
Note: Revision G provides separate Meat application settings.
2 of 9 C5X-EP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Convertible
09-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C5X
4 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/
8 (1229) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.) Optional view end with bumper adds 3 3/4 in. [95 mm]).
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs NA 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/
4 (921) 84
1
/
4 (2140) 132
3
/
8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
C5X-EP DAIRY/DELI
P
RODUCE Meat
U
NLIT LIT UNLIT LIT
Discharge Air (°F) 33 31 30 28
Evaporator (°F) 28 26 25 23
Unit Sizing (°F) 26 24 23 21
Btu/hr/ft
— Unlit Shelves
‡‡
C5X-EP DAIRY/DELI/PRODUCE Meat
P
ARALLEL 1420 1490
C
ONVENTIONAL 1490 1565
Optional energy efficient motors reduce the
refrigeration load by 46 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C5X-EP DAIRY/DELI/PRODUCE Meat
Frequency Hrs 12 6
Defrost Water
(lb/ft/day)
10.5 12.6
(± 15% based on case configuration and product
loading).
OFFTIME
D
AIRY/DELI
/PRODUCE Meat
TIME (minutes) 30 30
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO*
C5X-EP D
AIRY/DELI/PRODUCE MEAT
Temp (°F) 19°F / 9°F 16°F / 6°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG
conversions.
Estimated Charge ** C5X-EP
4 ft 1.9 lb 30 oz 0.9 kg
8 ft 3.7 lb 59 oz 1.7 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 9
P/N 0480105_G
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
30 1/4
(768)
61
(1549)
42
(1064)
FAN
C O
I
L
C5X-EP
3 In. (77 mm)
Required
Air Gap
81 3/4
(2077)
7 1/4 (183)
26 1/4 (665)
Refrigeration Outlet
6
(152)
Electrical
Case to Case
Connections
17 1/8
(436)
21 1/4
(540)
23 5/8
(600)
3 5/8
(92)
50 7/8
(1292)
Impact
Excel
C5X-EP
Meat/Delicatessen/Dairy
Precut & Packaged Produce
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.