Hussmann C5E Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0407833B
Note: Changed items have been underlined.
Merchandisers
®
D
D
C
C5E
Data Sheet Set
P/N 0407833B
NSF
®
Certified
August 2004
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0380485 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
Page 2
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C5E Data Sheet
Dimensions shown as inches and (mm).
Engineering
Plan View
8 ft 12 ft
General
(A)
Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670) Maximum O/S dimension of case back to front (includes bumper) 46 1/4 (1174) 46 1/4 (1174) Back of case to front of splashguard 38 5/
8 (981) 38
5
/
8 (981)
Back of case to O/S edge of front skid rail 29
1
/
2 (749) 29
1
/
2 (749)
Width of skid rail 4
1
/2 (114) 4 1/2 (114)
RH end of case to outside edge of external support 5 1/
2 (140) 5
1
/
2 (140)
Distance between edges of external support and center support 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 7 (178) 7 (178)
Electrical Service (Electrical Field Wiring connection point)
(B)
RH End of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467) Back of case to center of knockout 35 3/8 (899) 35 3/8 (899) Length of electrical raceway 34 5/
8
(878) 34
5
/
8
(878)
Waste Outlet
(C)
RH End of case to the center of waste outlet 24 1/8
(613) 72
1
/4
(1835)
LH End of case to the center of waste outlet 72
1
/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 1/
2 (699) 27
1
/
2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/
8 (778) 30
5
/
8 (778)
(D)
RH end of case to center of refrigeration outlet 9 (230) 9 (230)
01-2004
Meat/Dairy/Delicatessen
Precut & Packaged
Produce
35 3/8
(899)
Electri cal
72 1/4
(1835)
40 5/8
(1032)
7 (178)
B
4 1/4 (108)
27 1/2
(699)
Waste Ou tlet
Water Seal
(See note)
Front
40 5/8
(1032)
Refrigeration
Outlet
30 5/8
(778)
4 (102)
C
D
51/2 (140) 13/8 (35)
41/2 (114)
29 1/2
(749)
38 5/8
(981)
A
46 1/4
(1174)
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F) and 55% R.H.
C5E Meat Produce Dairy
Discharge Air (°F) 29 31 31
Evaporator (°F) 21 24 24
Unit Sizing (°F) 19 22 22
Btu/hr/ft** C5E
Parallel 1770 1710 1650
Conventional 1875 1810 1750
**For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
C5E Frequency (hr) 6 Defrost Water 10.5 lb/ft/day
(± 15% based on case configuration and
product loading).
OFFTIME C5E
Temp Term (°F) 48° Failsafe (min) 30
ELECTRIC OR
GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO (Temp °F)***
C5E Meat Produce Dairy
Temp (°F) 14°/ 4° 17°/ 7° 17°/ 7°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)*** 48°
***Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/2 Liquid Line (in.)
3
/8
Suction Line (in.)
7
/
8
Estimated Charge (lb)**** C5E 8 ft 3.2 12 ft 4.5
****This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by Each End or Insulated Partition (in.) 1 1/2
P/N 0407833B
3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C5E
FAN
Lighted Shelf
(Optional)
6 1/8
(155)
C O
I
L
7
1
/
2
(191)
81
1
/
4
(2064)
30 1/2
(774)
22 (559)
6 1/2 (165)
61
(1549)
23
(584)
18 1/8
(460)
5 3/4
(146)
4 3/8 (111 )
27 1/2 (699)
29 1/2 (749)
35 3/8 (899)
30 5/8 (778)
38 5/8 (981)
46 1/4 (1174)
45 1/2
(1156)
52
1
/
4
(1327)
Refriger ation Outlet
7 (178)
Impact
C5E
Meat/Delicatessen/Dairy
Precut & Packaged Produce
Multi-deck, 5 Display Levels
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
Page 4
Electrical Data
8 Ft 12 Ft
Number of Fans — 9W 4 6
Amperes Watts
Merchandiser 8 Ft 12 Ft 8 Ft 12 Ft
Fans
Standard (120V 60Hz) 2.80 4.20 210 330
Export (230V 50Hz) 1.52 2.28 228 342
Energy Efficient (120V 60Hz) 1.52 2.28 100 150
Constant on Anti-sweat Heaters NA
Cycling Anti-sweat Heaters NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 3.00 4.40
Export (230V 50Hz) 1.72 2.48
With Energy Efficient Fans (120V 60Hz) 1.72 2.48
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Supplemental Gas Heaters NA
208V 1ΦΦElectric Defrost NA
Standard Lighting
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Rail 1.02 1.54 118 170
2 Row Canopy 1.02 1.54 118 170
2 Row Canopy and 1 Row Rail 1.53 2.31 177 255
1 Row Ledge Lights 0.51 0.77 59 85
Optional Shelf Lighting
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
4 Rows of Shelves 2.04 3.08 236 340
4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C5E Data Sheet
Impact
C5E
Meat/Delicatessen/Dairy Precut & Packaged Produce
PPrreliminar
eliminaryy
Page 5
P/N 0407833B
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
3
To Condensing Unit
}
Light Blue
2
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL = Field GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
= Case GROUND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
120 V
Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
5
4
W
BL
R
5
BL
R
G
G
R
R
R
G
Shelf Lighting
G G
R
BL
5
BL
Connector
Connector
B
4 & 6 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
5 of 6
Page 6
C5E Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
6 of 6
Lighting 1 Row Canopy (Standard on Multi-deck)
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
Optional Lighting 2 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
W
B
4
R
BL
4
BL
4
BL
BL
R
R
BL
BL
BL
R
BL
R
BL
R
R
5
R
5
R
5
Optional Lighting 1 Row Rail
120V NEUTRAL
120V POWER
All components must have mechanical ground, and the merchandiser must be grounded.
ORANGE OR TAN BAND
Light
Switch
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
ORANGE OR TAN BAND
W
B
4
R
BL
BL
WARNING
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
= 120V P
OWER = 120V NEUTRAL
BL
R
R
5
Loading...