Hussmann C4LE Technical Data Sheet

P/N 0407950_C
Note:
Revision C updates measurements on Pages 2 and 3 and adds Aftermarket Part Numbers on Page 1.
Merchandisers
®
C
D
D
B
A
C4LE
Technical Data Sheet
P/N 0407950_C
NSF
®
Certified
September 2007
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0380485 Fan Blade (FB.0380485)
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat (CT.4481084)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. Ballast, Electronic
0428648 2 lamps (BA.4480823) (4) 0428649 3 lamps (BA.0428649)
E. Fluorescent Lamp (5)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C4LE Technical Data Sheet
Dimensions shown as inches and (mm).
Engineering
Plan View
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
Maximum O/S dimension of case back to front (includes bumper) 46 5/8 (1184) 46 5/8 (1184) Back of case to front of splashguard 35 3/
8 (899) 35
3
/
8 (899)
Back of case to O/S edge of front skid rail 29
1
/
2 (749) 29
1
/
2 (749)
Width of skid rail 2
3
/8 (60) 2 3/8 (60)
RH end of case to outside edge of external support 5 1/
2 (140) 5
1
/
2 (140)
Distance between edges of external support and center support 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 4
1
/4 (108) 41/4 (108)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 31 (787) 31 (787) Length of electrical raceway 34 5/
8
(878) 34
5
/
8
(878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24
1
/8
(613) 72
1
/4
(1835)
LH End of case to the center of waste outlet 72
1
/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 5/
8 (702) 27
5
/
8 (702)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/
8 (778) 30
5
/
8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
01-2004
Meat/Dairy/Delicatessen
Precut & Packaged
Produce
A
72 1/4
(1835)
31
(787)
40 5/8
(1032)
Electrical
4 (102)
B
4 1/4 (108)
27 5/8
(702)
Waste Outlet
Water Seal
(See note)
Front
40 5/8
(1032)
Refrigeration
Outlet
30 5/8
(778)
4 (102)
C
D
51/2 (140) 13/8 (35)
29 1/2
(749)
35 3/8
(899)
46 5/8
(1184)
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F) and 55% R.H.
C4LE Meat Produce Dairy
Discharge Air (°F) 29 31 31
Evaporator (°F) 21 24 24
Unit Sizing (°F) 19 22 22
Btu/hr/ft C4LE
Parallel 1635 1600 1485
Conventional 1730 1700 1570
DEFROST DATA
C4LE Frequency (hr) 6 Defrost Water 8 lb/ft/day
(± 15% based on case configuration and
product loading).
OFFTIME C4LE
Temp Term (°F) 48° Failsafe (min) 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO (Temp °F)
*
C4LE Meat Produce Dairy
Temp (°F) 14°/ 4° 17°/ 7° 17°/ 7°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)
* 48°
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/2 Liquid Line (in.)
3
/8
Suction Line (in.)
7
/8
Estimated Charge (lb)** C4LE 8 ft 3.2 12 ft 4.5
**This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by Each End or Insulated Partition (in.) 1 1/2
P/N 0407950_C 3 of 6
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact C4LE
Meat/Delicatessen/Dairy
Precut & Packaged Produce
Multi-deck, 4 Display Levels
Dimensions shown as inches and (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
C4LE
26 3/8
(670)
1
7
(191)
21 1/2
(546)
/2
51 1/8
(1299)
3
53
(1549)
2 1/2 (64)
Refrigeration Outlet
45 1/2
(1156)
/4
(406)
18
(457)
Lighted Shelf
(Optional)
18
(457)
20
(508)
30 1/2
(774)
16
FAN
C O
L
1
81
(2064)
/4
I
13 1/2
(343)
12 5/8
(321)
4 1/4 (108)
19 1/4 (489)
27 5/8 (702)
29 1/2 (749)
30 5/8 (778)
31 (787)
35 3/8 (899)
4 3/8 (111 )
46 5/8 (1184)
Electrical Data
8 Ft 12 Ft
Number of Fans — 9W 4 6
Amperes Watts
Merchandiser 8 Ft 12 Ft 8 Ft 12 Ft
Fans
120V 60Hz Standard 2.80 4.20 210 330
230V 50Hz Export 1.52 2.28 228 342
120V 60Hz Energy Efficient 1.52 2.28 100 150
Constant on Anti-sweat Heaters NA
Cycling Anti-sweat Heaters NA
Minimum Circuit Ampacity
120V 60Hz With Standard Fans 3.00 4.40
230V 50Hz Export 1.72 2.48
120V 60Hz With Energy Efficient Fans 1.72 2.48
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Supplemental Gas Heaters NA
208V Electric Defrost NA
Standard Lighting
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row of Canopy and 1 Row of Rail 1.02 1.54 118 170
2 Rows of Canopy 1.02 1.54 118 170
2 Rows of Canopy and 1 Row of Rail 1.53 2.31 177 255
1 Row of Ledge Lights 0.51 0.77 59 85
Optional Shelf Lighting
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
4 Rows of Shelves 2.04 3.08 236 340
4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C4LE Technical Data Sheet
Impact
C4LE
Meat/Delicatessen/Dairy Precut & Packaged Produce
P/N 0407950_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
3
To Condensing Unit
}
Light Blue
2
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
= Case GROUND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
120 V
Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
5
4
W
BL
R
5
BL
R
G
G
R
R
R
G
Shelf Lighting
G G
R
BL
5
BL
Connector
Connector
B
4 & 6 Fans
120V NEUTRAL
BROWN BAND
120V POWER
Fans
1
B
ROWN BAND
5 of 6
C4LE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
6 of 6
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
4
BL
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
4
W
B
4
BL
R
BL
BL
BL
5
R
R
BL
BL
5
R
5
BL
R
55
BL
R
5
R
5
R
5
R
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 ft models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER
= 120V NEUTRAL
Loading...