Hussmann C3X-LGEP Specifications

Page 1
P/N_0494876_E
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
E
D
B
D
A
E
C
F
H
G
Technical Data Sheet
P/N 0494876_E
NSF
®
Certified
March 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
6 Ft Only
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
H
EATERS
C. Canopy Anti-Sweat Heater (3)
0488622 6 ft (HE.4850617) 0488623 8 ft (HE.4850618) 0488624 12 ft (HE.4850619)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
H. LED Shelf Fixture (8)
Replace with like fixtures — See Page 5.
Note: Rev. E adds EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
Page 2
2 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C3X-LGEP Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy/Delicatessen
Precut & Packaged Produce
01-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C3X
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60
1
/
4 (1530) 84
1
/
4 (2140) 132
3
/
8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway 26
1
/
2 (673) 26
1
/
2 (673) 26
1
/
2 (673)
(C) RH End of case to LH end of wireway 66
1
/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/
8 (804) 31
5
/
8 (804) 31
5
/
8 (804)
Schedule 40 PVC drip pipe 1
1
/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C3X-LGEP Unlit Lit
Discharge Air °F 32 30
Evaporator °F 28 26
Unit Sizing °F 26 24
Btu/hr/ft
— Unlit Shelves
‡‡
C3X-LGEP Parallel Conventional
U
NLIT 1145 1220
Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C3X-LGEP
Frequency (hr) 8
Defrost Water (lb/ft/day) 6
(±15% based on case configuration and product loading.
O
FFTIME C3X-LGEP
Failsafe Minutes 30
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C3X-LGEP
CI/CO* 19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)**C3X-LGEP
6 ft 2.8
8 ft 3.7
12 ft 5.1
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a
Dimensions shown as inches and (mm).
P/N 0494876_E 3 of 12
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
66 3/8
(1696)
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
C3X-LGEP
30
(762)
18 1/2
(470)
FAN
C O
I
L
17 3/8
(440)
3 In. (77 mm)
Required
Air Gap
6 (152)
Electrical
Case to Case
Connections
17 1/8
(436)
Refrigeration
Outlet
3 5/8
(92)
42 5/8
(1082)
26 7/8
(683)
41
(1041)
3 3/4 (95)
7 1/4
(184)
Multi-deck, 4 Display Levels, Low Front with Glass
Impact
Excel
C3X-LGEP
Dairy / Delicatessen
Precut and Packaged Produce
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 11 for shelf arrangement.
Page 4
4 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C3X-LGEP Technical Data Sheet
Electrical Data
6 ft 8 ft 12 ft Number of Fans—12W 2 3 Number of Fans—7W 2
Amperes Watts
6 ft 8 ft 12 ft 6 ft 8 ft 12 ft Evaporator Fan
120V 60Hz Standard 1.00 1.30 1.95 78 100 150 120V 50Hz Standard 1.10 1.50 2.25 84 114 171 230V 60Hz Export 0.50 0.66 0.99 78 100 150 230V 50Hz Export 0.56 0.76 1.14 84 114 171 120V 60Hz Energy Efficient 0.38 0.60 0.90 28 36 54 230V 60Hz Energy Efficient 0.20 0.30 0.45 28 36 54
Minimum Circuit Ampacity
120V 60Hz Standard 1.20 1.50 2.15 120V 50Hz Standard 1.30 1.70 2.45 230V 60Hz Export 0.70 0.86 1.19 230V 50Hz Export 0.76 0.96 1.34 120V 60Hz Energy Efficient 0.58 0.80 1.10 230V 60Hz Energy Efficient 0.40 0.50 0.65
Maximum Over Current Protection 120V 20 20 20 Maximum Over Current Protection 230V 15 15 15
Anti-sweat Heaters
120V 50/60Hz Standard 0.15 0.20 0.30 18 24 36
Standard Lighting (T-8 Fluorescent)
1 Row Canopy 0.51 0.51 0.77 59 59 85
Optional Lighting (T-8 Fluorescent)
Additional 1 Row Canopy 0.51 0.51 0.77 59 59 85 1 Row Rail Light NA — Glass front does not accept rail light 1 Row of Shelves 0.51 0.51 0.77 59 59 85 2 Rows of Shelves 1.02 1.02 1.54 118 118 170 3 Rows of Shelves 1.53 1.53 2.31 177 177 255
EcoShine Multi-deck Canopy Normal (CRI) — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.41 0.55 0.82 49 66 98 1 Row of Shelves 0.15 0.20 0.29 18 24 35 2 Rows of Shelves 0.29 0.39 0.58 35 47 70 3 Rows of Shelves 0.44 0.58 0.88 53 70 105
EcoShine Multi-deck Canopy High CRI — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.47 0.63 0.93 56 75 112 1 Row of Shelves 0.18 0.23 0.35 21 28 42 2 Rows of Shelves 0.35 0.47 0.70 42 56 84 3 Rows of Shelves 0.53 0.70 1.05 63 84 126
Always*Bright Multi-deck Canopy — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.55 0.71 1.08 66 85 130 1 Row of Shelves 0.19 0.23 0.38 23 28 45 2 Rows of Shelves 0.34 0.47 0.67 41 56 80 3 Rows of Shelves 0.53 0.74 1.11 63 89 133
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
Impact
Excel
C3X-LGEP
Dairy / Delicatessen Precut and Packaged Produce
Page 5
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
6 ft 8 ft 12 ft (each)
lb (kg) 800 (363) 1000 (454) 1200 (544) 100 (45)
4
Actual weights will vary according to optional kits included.
5 of 12P/N 0494876_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
C3X-LGEP
Dairy / Delicatessen
Precut and Packaged Produce
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 4.77 ft3 /ft (0.44 m3 /m)
AHRI Total Display Area
2
(Sq Ft/Ft) 4.07 ft2/ft (1.24 m2 /m)
Shelf Area 3(Sq Ft/Ft) 6.02 ft2/ft (1.84 m2 /m)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (1) row of 12-inch shelf, (1) row of 14-inch shelf and (1) row of 16-inch shelf.
PARTS LIST (Continued from Page 1)
Note: Always*Bright lamps will be replaced with the latest generation of EcoShine lamps.
Item Part # Description
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. EcoShine LED Canopy Fixture (7)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
4441712 Front 36-inch 2900K HCRI 4441714 Front 36-inch 3500K HCRI 4441716 Front 36-inch 3500K 4441718 Front 36-inch 4100K
Item Part # Description
G.
(CONTINUED) EcoShine LED Canopy Fixture
4441713 Rear 36-inch 2900K HCRI 4441715 Rear 36-inch 3500K HCRI 4441717 Rear 36-inch 3500K 4441719 Rear 36-inch 4100K
H. EcoShine LED Shelf Fixture (8)
4441590 48-inch 2900K HCRI 4441591 48-inch 3500K HCRI 4441592 48-inch 3500K 4441593 48-inch 4100K
4441586 36-inch 2900K HCRI 4441587 36-inch 3500K HCRI 4441588 36-inch 3500K 4441589 36-inch 4100K
Page 6
6 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C3X-LGEP Technical Data Sheet
Refrigeration
Thermostat
2
To Condensing Unit
}
Light Blue
2 & 3 Fans
120V NEUTRAL
BROWN BAND
120V POWER
Fans
1
B
ROWN BAND
6 ft 8 ft
12 ft
12 ft
5
5
4
4
5
5
5
5
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
BK
6 ft or8 ft 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring Offtime Defrost
Canopy Light Circuits — Fluorescent Fixtures
Page 7
Purple BAND
3
120V Power
Purple BAND
120V Neutral
Anti-Sweat Heater
7 of 12P/N 0494876_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
5
5
5
BK
W
BL
BL
R
BL
BL
BL
R
W
R
BK
R
4
BL
BL
BL
R
R
R
R
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and Light Circuits for Three Rows of Shelves
5
5
5
BK
W
6 ft or 8 ft case
12 ft case
BL
BL
R
BL
BL
BL
R
W
R
BK
R
4
BL
BL
BL
R
R
R
R
5
5
5
BK
W
BL
BL
R
BL
BL
BL
R
W
R
BK
R
4
BL
BL
BL
R
R
R
R
Canopy
Anti-Sweat Heater
Optional Shelf Lighting
Fluorescent Fixtures
Page 8
8 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C3X-LGEP Technical Data Sheet
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
7
7
7
7
7
7
7
7
7
7
6
6
6
Optional Canopy Lighting LED Fixtures
Page 9
9 of 12P/N 0494876_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
8
8
8
8
8
8
8
R
BL
6
BK
BK
W
W
BL
R
G
6 ft or 8 ft case
12 ft case
(TYP)
Shelf Light
Plug & Receptacle
BK
Connector
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
8
8
8
8
8
8
8
R
BL
6
BK
BK
W
W
BL
R
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
8
8
8
8
8
8
8
R
BL
6
BK
BK
W
W
BL
R
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
W
Connector
Optional Shelf Harness and LED Light Circuits for 3, 4, 5, 6 & 7 Rows of Shelves
BK
W
Optional Shelf Lighting
LED Fixtures
Page 10
10 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C3X-LGEP Technical Data Sheet
6 ft or 8 ft case
12 ft case
R
BL
R
BL
8
8
R
BL
6
BK
W
W
BL
R
G
Connector
Connector
BK
W
BK
W
BK
W
R
BL
R
BL
8
8
R
BL
R
BL
R
BL
8
8
R
BL
R
BL
BL
BL
(TYP)
Shelf Light
Plug & Receptacle
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves
R
R
BK
Optional Shelf Lighting LED Fixtures
Page 11
11 of 12P/N 0494876_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Remove Screws
Light Channel
Light Channel
Hinge
Ballast
Light
Channel
Foil-covered Anti-sweat Heater
Canopy
Canopy
Anti-Sweat Heater Wires with Purple Markers
Electrical Wireway
The ballast for the canopy and shelf lamps is located behind the canopy on the left-hand end (when facing case) of the merchandiser.
To access the ballast:
1. Remove screws at bottom edge of canopy and rear of light channel.
2. Lower light channel which will pivot on hinge.
3. Service or replace ballasts as required.
4. Reassemble items as they were originally installed.
NOTE: Rail lamp ballast is located in the electrical raceway.
CANOPY ANTI-SWEAT HEATER
The canopy anti-sweat heater location is shown below. Connections are in the electrical wireway.
Impact
Excel
C3X-LGEP
Dairy/Delicatessen
Precut & Packaged Produce
Page 12
12 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C3X-LGEP Technical Data Sheet
Top Shelf
(12 in., 15o Shown)
Second Shelf
(16 in., 15o Shown)
Third Shelf
(18 in., 15o Shown)
SHELF CONFIGURATION
This case is designed for three (3) shelves.
The depth of the shelves used are critical to case performance.
The use of peg shelves is NOT recommended on C3X-LGEP cases. Depth and angle requirements are listed below.
Top Shelf
Shelf Depth Shelf Angle
12 inches 0 º,10 º,15º,30 º,45 º
14 inches 30 º,45 º
Second Shelf
Shelf Depth Shelf Angle
14 inches 0 º,10 º,15º,30 º,45 º
16 inches 30 º,45 º
Third Shelf
Shelf Depth Shelf Angle
16 inches 0 º,10 º,15º,30 º,45 º
18 inches 30 º,45 º
Impact
Excel
C3X-LGEP
Dairy/Delicatessen
Precut & Packaged Produce
Loading...