Hussmann C2X-LGE Specifications

F
B
E
C
E
A
F
D
G
I
H
C2X-LGE
Technical Data Sheet
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
8 Ft & 12 Ft
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
6 Ft Only
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0382383 Fan Blade (FB.4780617) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0382383 Fan Blade (FB.4780617)
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
H
EATERS
D. Canopy Anti-Sweat Heater (4)
0512500 6 ft (HE.4851175) 0512501 8 ft (HE.4851176) 0512503 12 ft (HE.4851178)
L
AMPS AND B
ALLASTS
E. Ballast, Electronic (5)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
F. Fluorescent Lamp (6)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
G. 0501213 Power Supply (EP.4481861) (7)
H. LED Canopy Fixture (8)
Replace with like fixtures — See Page 5.
I. LED Shelf Fixture (9)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
P/N0466000H
Note: Rev. H adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 11 C2X-LGE Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy/Delicatessen
Precut & Packaged Produce
01-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C2X
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60
1
/
4 (1530) 84
1
/
4 (2140) 132
3
/
8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway 26
1
/
2 (673) 26
1
/
2 (673) 26
1
/
2 (673)
(C) RH End of case to LH end of wireway 66
1
/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/
8 (804) 31
5
/
8 (804) 31
5
/
8 (804)
Schedule 40 PVC drip pipe 1
1
/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
Dimensions shown as inches and (mm).
P/N 0466000_H
48 1/2
(1232)
31 5/8 (804)
4 3/4 (128)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
C2X-LGE
30
(762)
15 7/8
(403)
FAN
C O
I
L
17 1/4
(438)
3 In. (77 mm)
Required
Air Gap
26 7/8
(683)
6 (152)
Electrical
Case to Case
Connections
17 1/8
(436)
Refrigeration
Outlet
3 5/8
(92)
29 1/2
(750)
24 5/8
(625)
7 1/4
(184)
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C2X-LGE
Discharge Air °F 27
Evaporator °F 21
Unit Sizing °F 19
Btu/hr/ft
— Unlit Shelves
‡‡
C2X-LGE Parallel Conventional
U
NLIT 955 1050
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft (4 ft, 6 ft and 8 ft
models) and 18 Btu/hr/ft (6 ft models). ‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C2X-LGE
Frequency (hr) 6
Defrost Water (lb/ft/day) 6
(±15% based on case configuration and
product loading.
O
FFTIME C2X-LGE
Temp Term °F 48°F
Failsafe Minutes 30
E
LECTRIC OR G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2X-LGE
CI/CO* 14 / 4°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** C2X-LGE
6 ft 1.6 26 oz 0.7 kg 8 ft 2.3 37 oz 1.0 kg
12 ft 3.3 53 oz 1.5 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Impact
Excel
C2X-LGE
Dairy/Delicatessen
Precut & Packaged Produce
Multi-deck, 3 Display Levels, Low Front with Glass, 48 In. Back
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 10 for shelf arrangement.
4 of 11 C2X-LGE Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Electrical Data
6 ft 8 ft 12 ft Number of Fans—7W 2 3 Number of Fans—4W 2
Amperes Watts
6 ft 8 ft 12 ft 6 ft 8 ft 12 ft Evaporator Fan
120V 60Hz Standard 0.62 1.00 1.50 48 78 117
120V 50Hz Standard 0.76 1.10 1.65 54 84 126
230V 60Hz Export 0.30 0.50 0.75 48 78 117
230V 50Hz Export 0.36 0.56 0.84 54 84 126
120V 60Hz Energy Efficient 0.24 0.38 0.57 16 28 42
230V 60Hz Energy Efficient 0.12 0.20 0.30 16 28 42
Minimum Circuit Ampacity †
120V 60Hz Standard 0.82 1.20 1.70
120V 50Hz Standard 0.96 1.30 1.85
230V 60Hz Export 0.50 0.70 0.95
230V 50Hz Export 0.56 0.76 1.04
120V 60Hz Energy Efficient 0.44 0.58 0.77
230V 60Hz Energy Efficient 0.32 0.40 0.50
Maximum Over Current Protection 120V 20 20 20 Maximum Over Current Protection 230V 15 15 15
Anti-sweat Heaters
120V 50/60Hz Standard 0.15 0.20 0.30 18 24 36
Standard Lighting (T-8 Fluorescent)
1 Row Canopy 0.51 0.51 0.77 59 59 85
Optional Lighting (T-8 Fluorescent)
Additional 1 Row Canopy 0.51 0.51 0.77 59 59 85
1 Row Rail Light NA — Glass front does not accept rail light
2 Rows of Shelves 1.02 1.02 1.54 118 118 170
Optional EcoShine LED Lighting — CRI
2 Row Canopy 0.41 0.54 0.83 49 65 98
2 Rows of Shelves 0.29 0.39 0.58 35 47 70
Optional EcoShine LED Lighting — High CRI
2 Row Canopy 0.47 0.62 0.93 56 74 112 2 Rows of Shelves 0.35 0.47 0.70 42 56 84
Optional Always*Bright LED Lighting
2 Row Canopy 0.55 0.71 1.08 66 85 130
2 Rows of Shelves 0.34 0.47 0.67 41 56 80
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
† MCA does not include Canopy A/S Heaters because heaters are wired separately from fans.
Impact
Excel
C2X-LGE
Dairy/Delicatessen Precut & Packaged Produce
Loading...
+ 7 hidden pages