Hussmann C2-XGEP Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0457230C
®
C2-XGEP
Technical Data Sheet
NSF
®
Certified
February 2006
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly (1)
0058698 Fan Motor, Evaporator 0142780 Fan Blade
embossing toward motor
B. 0137880 Optional Adjustable (2)
Refrigeration Thermostat
Item Part # Description Wiring Item #
HEATERS
C. Canopy Anti-Sweat Heater (3)
NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0428648 2 lamps 0428649 3 lamps 0428650 4 lamps
E. Fluorescent Lamp (5)
Replace with like fixtures
Note: Changes are NOT underlined. Revision A added the canopy anti-sweat heater (pages 1, 4, 5 & 8); added 4-ft and 6-ft data (pages 1, 2, 3 & 4); and updated wiring diagrams. Revision B returned the correct data to page 3. Revision C returned the correct data to page 1.
Merchandisers
D
B
E
C
D
E
E
A
2 of 8 C2-XGEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy / Delicatessen
Precut & Packaged
Produce
05-2003
4 ft 6 ft 8 ft 12 ft
General (A) Case Length (without ends or partitions) 48 1/
4 (1226) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case
back to front (includes bumper) 46 1/
2 (1182) 46
1
/
2 (1182) 46
1
/
2 (1182) 46
1
/
2 (1182)
Back of case to front of splashguard 38
7
/
8 (986) 38
7
/
8 (986) 38
7
/
8 (986) 38
7
/
8 (986)
Back of case to O/S edge of front skid rail 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140)
Distance between edges of external and center supports NA 31
1
/
8 (790) 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports 41
1
/
4 (1048) NA NA 44 (1118)
Stub-up area between front skid rail and splashguard 7
3
/
4 (199) 7
3
/
4 (199) 7
3
/
4 (199) 7
3
/
4 (199)
Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of farthest knockout 38 1/4 (972) 64 3/8 (1635) 88 3/8 (2245) 136 1/2 (3467)
Back O/S of case to center of knockout 34
5
/8 (881) 34 5/8 (881) 34 5/8 (881) 34 5/8 (881)
Length of electrical raceway 16
1
/8 (410) 34 1/2 (876) 35 5/8 (903) 35 5/8 (903)
Waste Outlet (C) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NNoottee::
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230) 9 (230) 9 (230)
72 1/4 (1835)
C2XGE
34 5/8
Elec.
(881)
Skid/ External Base
7 3/4 (199)
Waste Outlet
A
B
27
Water Seal
(see note)
Front
5
/8
(703)
(102)
C
29 1/4
(743)
30 5/8
D
(778)
38 7/8
(98 6)
46 1/2
(1182)
4
Refrig.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
C2-XGEP U
NLIT LIT
Discharge Air (°F) 32 30 Evaporator (°F) 28 26 Unit Sizing (°F) 26 24
Btu/hr/ft* U
NLIT LIT
Parallel 725 825 Conventional 755 860
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
C2-XGEP Frequency (hr) 12 Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
OFFTIME C2-XGEP
Time (minutes) 30
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2-XGEP
CI/CO** 19°F / 9°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)7/8
Estimated Charge (lb)*** 4 ft 1.6 6 ft 2.3 8 ft 3.2 12 ft 4.5
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 8
P/N 0457230C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
(Note:* Optional accessory items).
C2XGEPLUS
19
(483)
3 3/4
(95)
12
(305)
(Note*)
18
(457)
(Note*)
(Note*)
18
(457)
(Note*)
31 3/4
(806)
30 1/2
(776)
(Note*)
18 1/4
(463)
55 1/2
(1400)
FAN
C O
I
L
5
1
/4
(132)
27 5/8 (703)
29 1/4 (743)
30 5/8 (778)
34 5/8 (881)
38 7/8 (987)
46 1/2 (1181)
7 3/4
(197)
30 1/8
(766)
6 1/8 (155)
Dimensions shown as inches and (mm).
Multi-deck, 3 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
Impact C2-XGEP
Dairy / Delicatessen
Precut & Packaged Produce
C2-XGEP
4 of 8 C2-XGEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact C2-XGEP
Dairy / Delicatessen Precut & Packaged Produce
Electrical Data
4 ft 6 ft 8 ft 12 ft
Number of Fans—6W 1 2 2 3
Amperes Watts
4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Evaporator Fan
120V 60Hz Standard 0.50 1.00 1.00 1.50 39 78 78 117
120V 50Hz Standard 0.55 1.10 1.10 1.65 42 84 84 126
230V 60Hz Export 0.25 0.50 0.50 0.75 40 80 80 120
230V 50Hz Export 0.28 0.56 0.56 0.84 44 88 88 132
120V 60Hz Energy Efficient 0.26 0.52 0.52 0.78 18 36 36 54
230V 60Hz Energy Efficient NA
Canopy Anti-sweat Heaters NA 0.75 0.75 1.00 45 90 90 120
Minimum Circuit Ampacity
120V 60Hz Standard 0.70 1.95 1.95 2.70
120V 50Hz Standard 0.75 2.05 2.05 2.85
230V 60Hz Export 0.45 1.45 1.45 1.95
230V 50Hz Export 0.48 1.51 1.51 2.04
120V 60Hz Energy Efficient 0.46 1.47 1.47 1.98
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15
Standard Lighting
1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Optional Lighting
Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170
1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85
1 Row Ledge Light 0.26 0.51 0.51 0.77 30 59 59 85
Optional Shelf Lighting
1 Row Shelf Receptacle 0.26 0.51 0.51 0.77 30 59 59 85
2 Row Shelf Receptacle 0.51 1.02 1.02 1.53 59 118 118 177
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52
5 of 8P/N 0457230C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
1, 2 & 3 Fans
4 ft 6 ft 8 ft
12 ft
120V POWER
BROWN BAND
Fans
Fan Wiring
Offtime Defrost
120V NEUTRAL
1
BROWN BAND
Refrigeration
2
Thermostat
Light Blue
To Condensing
}
Unit
120V Power
Purple BAND
3
Anti-Sweat Heater
120V Neutral
Purple BAND
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
R
BL
Connector
W
G
B
G
Connector
W
G
B
120 V
Powe r
Connector
G
B
W
4
G
BL
R
BL
BL
Canopy
Anti-Sweat Heater
Shelf Lighting
Connector
G
BL
R
BL
R
Connector
G
BL
R
G
G
R
BL
Connector
Shelf Light Circuits
BL
Connector
G
Connector
G G
R
BL
5
R
5
Connector
BL
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= 120V P
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
OWER = 120V NEUTRAL = Field GROUND
= Case G
ROUND
R
6 of 8 C2-XGEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Note: Optional Construction for 2 Rows Canopy on the 8 ft would be to wire (1) 4-lamp ballast.
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
4
R
BL
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
4
W
B
4
R
BL
R
BL
BL
BL
R
55
BL
BL
R
5
BL
5
5
BL
R
5
R
5
R
5
R
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL
7 of 8P/N 0457230C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
SHELF CONFIGURATION
This merchandiser is designed for two or three shelves.
The depth of the shelf used in the top eight (8) shelf hole locations is critical to case performance.
If a shelf is placed in one of the top eight (8) locations it must comply with the angle/depth requirements listed below.
Maximum Shelf
Shelf Angle Depth
0 º 12 in.
15 º 14 in.
or less
30 º 18 in.
or less
45 º 18 in.
or less
NOTE: Shelves placed in the lower positions may be up to 18 in. deep when positioned at a 0 º angle.
Impact C2-XGEP
Dairy / Delicatessen
Precut & Packaged Produce
Angle
15°
30°
45°
Top Eight (8) Shelf Hole Locations
Maximum
Shelf
Size
12 in.
14 in.
18 in.
18 in.
18 in.
18 in.
C2-XGEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
8 of 8
Impact C2-XGEP
Dairy / Delicatessen Precut & Packaged Produce
The ballast for the canopy and shelf lamps is located behind the light tray on the left-hand end (when facing case) of the merchandiser.
To access the ballast:
1. Remove screws from the front-lip of light tray flange covering the bottom edge of the canopy. Also remove screws located near the middle-rear of light tray.
2. Swing front of light channel down on it’s rear hinge.
3. Service or replace ballasts as required.
4. Reassemble items as they were originally installed. Make sure that wires are not pinched by re-installed light tray.
NOTE: Rail lamp ballast is located behind the lower front panel.
CANOPY ANTI-SWEAT HEATER
The canopy anti-sweat heater location is shown below. Connections are in the Electrical wireway.
Remove Screws
Ballast
Light Tray
Light Tray
Hinge
Canopy
Foil-covered Anti-sweat Heater
Electrical Wireway
Light Tray
Canopy
Anti-Sweat Heater Wires with Purple Markers
Loading...