Hussmann C2X-EP Specifications

E
D
B
E
D
A
E
C
F
H
G
C2X-EP
Technical Data Sheet
P/N 0465997_I
®
Certified
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
H
EATERS
C. Canopy Anti-Sweat Heater (3)
0512501
8 ft (HE.4851176
)
0512503
12 ft (HE.4851178)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
H. LED Shelf Fixture (8)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
P/N0465997I
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Rev. I adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by underline or circle.
2 of 11 C2X-EP Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy/Delicatessen
Precut & Packaged Produce
01-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C2X
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 41 1/2
(1054) 41
1
/2
(1054)
Distance between edges of center legs NA 43
7
/8 (1114)
Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84
1
/4
(2140) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/
8
Wireway
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C2X-EP Dairy/Deli/Produce Meat
U
NLIT L
IT UNLIT LIT
Discharge Air °F 33 31 30 28
Evaporator °F 28 26 25 23
Unit Sizing °F 26 24 23 21
Btu/hr/ft
— Unlit Shelves
‡‡
C2X-EP Dairy/Deli/Produce Meat
P
ARALLEL
590 620
C
ONVENTIONAL 615 645
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C2X-EP
Frequency (hr) 12
Defrost Water (lb/ft/day) 6
(±15% based on case configuration and
product loading.
O
FFTIME C2X-EP
Time (minutes) 30
E
LECTRIC OR GAS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2X-EP Dairy/Deli/Produce Meat
CI/CO* 19°F / 9°F16°F / 6°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** C2X-EP
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Dimensions shown as inches and (mm).
P/N 0465997_I
48 1/2
(1232)
30 1/4
(769)
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
C2X-EP
15 7/8
(403)
30 7/8
(784)
FAN
C O
I
L
21 1/4
(540)
3 In. (77 mm)
Required
Air Gap
23 5/8
(600)
6 (152)
Electrical
Case to Case
Connections
17 1/8
(436)
Refrigeration
Outlet
3 3/4
(95)
24 5/8
(625)
Impact
Excel
C2X-EP
Dairy/Delicatessen
Precut & Packaged Produce
Multi-deck, 3 Display Levels, 48 In. Back
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 10 for shelf arrangement.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
3 of 11
4 of 11 C2X-EP Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Electrical Data
8 ft 12 ft
Number of Fans—7W 2 3
Amperes Watts
8 ft 12 ft 8 ft 12 ft
Evaporator Fan
120V 60Hz Standard 1.00 1.50 78 117
120V 50Hz Standard 1.10 1.65 84 126
230V 60Hz Export 0.50 0.75 78 117
230V 50Hz Export 0.56 0.84 84 126
120V 60Hz Energy Efficient 0.38 0.57 28 42
230V 60Hz Energy Efficient 0.20 0.30 28 42
Minimum Circuit Ampacity †
120V 60Hz Standard 1.20 1.70
120V 50Hz Standard 1.30 1.85
230V 60Hz Export 0.70 0.95
230V 50Hz Export 0.76 1.04
120V 60Hz Energy Efficient 0.58 0.77
230V 60Hz Energy Efficient 0.40 0.50
Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15
Anti-sweat Heaters
120V 50/60Hz Standard 0.20 0.30 24 36
Standard Lighting (T-8 Fluorescent)
1 Row Canopy 0.51 0.77 59 85
Optional Lighting (T-8 Fluorescent)
Additional 1 Row Canopy 0.51 0.77 59 85
1 Row Rail Light 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
Optional EcoShine LED Lighting — CRI
2 Row Canopy 0.55 0.82 66 98
2 Row of Shelves 0.39 0.58 47 70
Optional EcoShine LED Lighting — High CRI
2 Row Canopy 0.63 0.93 75 112
2 Row of Shelves 0.47 0.70 56 84
Optional Always*Bright LED Lighting
2 Row Canopy 0.71 1.08 85 130
2 Row of Shelves 0.47 0.67 56 80
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
† MCA does not include Canopy A/S Heaters because heaters are wired separately from fans.
Impact
Excel
C2X-EP
Dairy/Delicatessen Precut & Packaged Produce
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
8 ft 12 ft (each)
lb (kg) 1000 (454) 1200 (544) 75 (34)
4
Actual weights will vary according to optional kits included.
5 of 11P/N 0465997_I
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
C2X-EP
Dairy/Delicatessen
Precut & Packaged Produce
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 3.08 ft3 /ft (0.29 m3 /m)
AHRI Total Display Area
2
(Sq Ft/Ft) 2.93 ft2/ft (0.89 m2 /m)
Shelf Area 3(Sq Ft/Ft) 5.04 ft2/ft (1.54 m2 /m)
1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft
3
/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (1) row of 12-inch shelf and (1) row of 18-inch shelf.
from fans.
PARTS LIST (Continued from Page 1)
Note: Always*Bright lamps will be replaced with the latest generation of EcoShine lamps.
Item Part # Description
LED FIXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. EcoShine LED Canopy Fixture (7)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
Item Part # Description
H. EcoShine LED Shelf Fixture (8)
4441590 48-inch 2900K HCRI 4441591 48-inch 3500K HCRI 4441592 48-inch 3500K 4441593 48-inch 4100K
6 of 11 C2X-EP Technical Data Sheet
5
5
4
4
5
5
5
5
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
5
4
55
Connector
W
BK
BL
BL
R
BL
R
R
R
BK
8 ft 12 ft
8 ft 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Fan Wiring Offtime Defrost
Light Circuits
Refrigeration
Thermostat
2
To Condensing Unit
}
Light Blue
120V NEUTRAL
BROWN BAND
120V POWER
Fans
1
B
ROWN BAND
8 ft
12 ft
12 ft
4
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and Light Circuits for Two Rows of Shelves
Connector
5
4
5
5
5
BK
W
Connector
8 ft case
12 ft case
BK
W
R
R
W
BL
BL
R
BK
BL
BL
R
5
4
5
BK
W
R
R
W
BL
BL
R
BK
BL
BL
R
W
BK
7 of 11P/N 0465997_I
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Purple BAND
3
120V Power
Purple BAND
120V Neutral
Anti-Sweat Heater
Canopy Anti-Sweat
Heater
Optional Shelf Lighting
Fluorescent Fixtures
8 of 11 C2X-EP Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
7
7
7
7
7
7
7
7
7
7
6
6
6
Optional Canopy Lighting LED Fixtures
9 of 11P/N 0465997_I
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
8 ft case
12 ft case
R
BL
R
BL
8
8
R
BL
6
BK
W
W
BL
R
G
Connector
Connector
BK
W
BK
W
BK
W
R
BL
R
BL
8
8
R
BL
R
BL
R
BL
8
8
R
BL
R
BL
BL
BL
(TYP)
Shelf Light
Plug & Receptacle
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves
R
R
BK
Optional Shelf Lighting
LED Fixtures
10 of 11 C2X-EP Technical Data Sheet
Top Eight (8) Shelf Hole Locations
18 in.
18 in.
14 in.
12 in.
Angle
Maximum
Shelf
Size
18 in.
Do NOT load
PRODUCT
above
this line
SHELF CONFIGURATION
This merchandiser is designed for one or two shelves.
The depth of the shelf used in the top eight (8) shelf hole locations is critical to case performance.
If a shelf is placed in one of the top eight (8) locations it must comply with the angle/depth requirements listed below.
Maximum Shelf
Shelf Angle Depth
0 º 12 in.
15 º 14 in.
or less
30 º 18 in.
or less
45 º 18 in.
or less
NOTE: Shelves placed in the lower positions may be up to 18 in. deep when positioned at a 0 º angle.
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Impact
Excel
C2X-EP
Dairy/Delicatessen
Precut & Packaged Produce
Impact
Excel
C2X-EP
Dairy/Delicatessen
Precut & Packaged Produce
11 of 11P/N 0465997_I
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Remove Screws
Light Channel
Light Channel
Hinge
Ballast
Light
Channel
Foil-covered Anti-sweat Heater
Canopy
Canopy
Anti-Sweat Heater Wires with Purple Markers
Electrical Wireway
The ballast for the canopy and shelf lamps is located behind the canopy on the left-hand end (when facing case) of the merchandiser.
To access the ballast:
1. Remove screws at bottom edge of canopy and rear of light channel.
2. Lower light channel which will pivot on hinge.
3. Service or replace ballasts as required.
4. Reassemble items as they were originally installed.
NOTE: Rail lamp ballast is located in the electrical raceway.
CANOPY ANTI-SWEAT HEATER
The canopy anti-sweat heater location is shown below. Connections are in the electrical wireway.
Loading...