Hussmann C2XEC-XE Specifications

P/N_0489566_D
E
B
E
C
A
F
D
F
G
I
F
H
C2XEC-XE
P/N 0489566_D
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
6 Ft Only
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0382383 Fan Blade (FB.4780617) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0382383 Fan Blade (FB.4780617)
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
H
EATERS
D. Canopy Anti-Sweat Heater (4)
0488622 6 ft (HE.4850617) 0488623 8 ft (HE.4850618) 0488624 12 ft (HE.4850619)
LAMPS & BALLASTS
E. Ballast, Electronic (5)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
F. Fluorescent Lamp (6)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
G. 0501213 Power Supply (EP.4481861) (7) H. LED Canopy Fixture (8)
Replace with like fixtures — See Page 5.
I. LED Shelf Fixture (9)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision D adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2XEC-XE Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy/Delicatessen
Precut & Packaged Produce
01-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
C2X
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/8
(1838) 96
3
/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60
1
/4
(1530) 84
1
/4
(2140) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C2XEC-XE
Discharge Air °F 29
Evaporator °F 21
Unit Sizing °F 19
Btu/hr/ft
— Unlit Shelves
‡‡
C2XEC-XE Parallel Conventional
U
NLIT
1080 1155
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft (8 ft and 12 ft
models) and 18 Btu/hr/ft (6 ft models).
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C2XEC-XE
Frequency (hr) 6
Defrost Water (lb/ft/day) 7
(±15% based on case configuration and product loading.
O
FFTIME
C2XEC-XE
Temp Term °F 48°F
Failsafe Minutes 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2XEC-XE
CI/CO* 17°F / 7°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** C2XEC-XE
6 ft 1.6 26 oz 0.7 kg 8 ft 2.3 37 oz 1.0 kg
12 ft 3.3 53 oz 1.5 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0489566_D 3 of 12
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
55 3/4
(1415)
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
C2XEC-XE
30 1/4
(768)
22
(559)
FAN
C O
I
L
3 In.
(77 mm)
Required
Air Gap
6 (152)
Electrical
Case to Case
Connections
17 1/8
(436)
33 1/8
(841)
31 7/8
(810)
21 1/4
(540)
23 5/8
(600)
3 5/8
(92)
Impact
Excel
C2XEC-XE
Dairy/Delicatessen
Precut & Packaged Produce
Multi-deck, 4 Display Levels, 55 In. Back
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 11 for shelf arrangement.
Dimensions shown as inches and (mm).
4 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2XEC-XE Technical Data Sheet
Electrical Data
6 ft 8 ft 12 ft Number of Fans—7W 2 3 Number of Fans—4W 2
Amperes Watts
Evaporator Fan 6 ft 8 ft 12 ft 6 ft 8 ft 12 ft
120V 60Hz Standard 0.62 1.00 1.50 48 78 117 120V 50Hz Standard 0.76 1.10 1.65 54 84 126 230V 60Hz Export 0.30 0.50 0.75 48 78 117 230V 50Hz Export 0.36 0.56 0.84 54 84 126 120V 60Hz Energy Efficient 0.24 0.38 0.57 16 28 42 230V 60Hz Energy Efficient 0.12 0.20 0.30 16 28 42
Minimum Circuit Ampacity †
120V 60Hz Standard 0.82 1.20 1.70 120V 50Hz Standard 0.96 1.30 1.85 230V 60Hz Export 0.50 0.70 0.95 230V 50Hz Export 0.56 0.76 1.04 120V 60Hz Energy Efficient 0.44 0.58 0.77 230V 60Hz Energy Efficient 0.32 0.40 0.50
Maximum Over Current Protection 120V 20 20 20 Maximum Over Current Protection 230V 15 15 15
Anti-sweat Heaters
120V 50/60Hz Standard 0.15 0.20 0.30 18 24 36
Standard Lighting (T-8 Fluorescent)
1 Row Canopy 0.51 0.51 0.77 59 59 85
Optional Lighting (T-8 Fluorescent)
Additional 1 Row Canopy 0.51 0.51 0.77 59 59 85 1 Row Rail Light 0.51 0.51 0.77 59 59 85 3 Rows of Shelves 1.53 1.53 2.31 177 177 255
Optional EcoShine LED Lighting — Normal CRI
2 Row Canopy 0.41 0.55 0.82 49 66 98 2 Rows of shelves 0.29 0.39 0.58 35 47 70
3 Row of Shelves 0.44 0.58 0.88 53 70 105
Optional EcoShine LED Lighting — High CRI
2 Row Canopy 0.47 0.63 0.93 56 75 112 2 Rows of Shelves 0.35 0.47 0.70 42 56 84 3 Rows of Shelves 0.53 0.70 1.05 63 84 126
Optional Always*Bright LED Lighting
2 Row Canopy 0.55 0.71 1.08 66 85 130 2 Rows of Shelves 0.34 0.47 0.67 41 56 80
3 Row of Shelves 0.53 0.74 1.11 63 89 133
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
† MCA does not include Canopy A/S Heaters because heaters are wired separately from fans.
Impact
Excel
C2XEC-XE
Dairy/Delicatessen
Precut & Packaged Produce
5 of 12P/N 0489566_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
C2XEC-XE
Dairy/Delicatessen
Precut & Packaged Produce
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
6 ft 8 ft 12 ft (each)
lb (kg) 800 (363) 1000 (454) 1200 (544) 75 (34)
4
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 3.85 ft3 /ft (0.36 m3 /m)
ARI Total Display Area
2
(Sq Ft/Ft) 3.29 ft2/ft (1.00 m2 /m)
Shelf Area 3(Sq Ft/Ft) 6.54 ft2/ft (1.99 m2 /m)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (1) row of 12-inch shelf, (1) row of 14-inch shelf and (1) row of 16-inch shelf.
PARTS LIST (Continued from Page 1)
Note: Always*Bright lamps will be replaced with the latest generation of EcoShine lamps.
Item Part # Description
LED F
IXTURES AND POWER SUPPLY
G. 0501213 Power Supply (EP.4481861) (7)
H. EcoShine LED Canopy Fixture (8)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
4441712 Front 36-inch 2900K HCRI 4441714 Front 36-inch 3500K HCRI 4441716 Front 36-inch 3500K 4441718 Front 36-inch 4100K
Item Part # Description
H.
(CONTINUED) EcoShine LED Canopy Fixture
4441713 Rear 36-inch 2900K HCRI 4441715 Rear 36-inch 3500K HCRI 4441717 Rear 36-inch 3500K 4441719 Rear 36-inch 4100K
I. EcoShine LED Shelf Fixture (9)
4441590 48-inch 2900K HCRI 4441591 48-inch 3500K HCRI 4441592 48-inch 3500K 4441593 48-inch 4100K
4441586 36-inch 2900K HCRI 4441587 36-inch 3500K HCRI 4441588 36-inch 3500K 4441589 36-inch 4100K
6 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2XEC-XE Technical Data Sheet
Defrost Termination Thermostat
Refrigeration
Thermostat
Dark Blue
3
To Condensing Unit
}
Light Blue
2
2 & 3 Fans
120V NEUTRAL
BROWN
B
AND
120V POWER
Fans
1
BROWN BAND
6 ft 8 ft
12 ft
12 ft
Fan Wiring
Offtime Defrost
6
6
5
5
6
6
6
6
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
6
5
66
Connector
W
BK
BL
BL
R
BL
R
R
R
BK
8 ft 12 ft
8 ft 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Canopy Light Circuits — Fluorescent Fixtures
7 of 12P/N 0489566_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
6
6
6
BK
W
BL
BL
R
BL
BL
BL
R
W
R
BK
R
5
BL
BL
BL
R
R
R
R
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and Light Circuits for Three Rows of Shelves
6
6
6
BK
W
6 ft or 8 ft case
12 ft case
BL
BL
R
BL
BL
BL
R
W
R
BK
R
5
BL
BL
BL
R
R
R
R
6
6
6
BK
W
BL
BL
R
BL
BL
BL
R
W
R
BK
R
5
BL
BL
BL
R
R
R
R
Purple BAND
4
120V Power
Purple BAND
120V Neutral
Anti-Sweat Heater
Canopy Anti-Sweat
Heater
Optional Shelf Lighting
Fluorescent Fixtures
8 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2XEC-XE Technical Data Sheet
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
8
8
8
8
8
8
8
8
8
8
7
7
7
Optional Canopy Lighting
LED Fixtures
9 of 12P/N 0489566_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
9
9
9
9
9
9
9
R
BL
7
BK
BK
W
W
BL
R
G
6 ft or 8 ft case
12 ft case
(TYP)
Shelf Light
Plug & Receptacle
BK
Connector
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
9
9
9
9
9
9
9
R
BL
7
BK
BK
W
W
BL
R
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
9
9
9
9
9
9
9
R
BL
7
BK
BK
W
W
BL
R
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
W
Connector
Optional Shelf Harness and LED Light Circuits for 3, 4, 5, 6 & 7 Rows of Shelves
BK
Optional Shelf Lighting
LED Fixtures
10 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2XEC-XE Technical Data Sheet
Optional Shelf Lighting
LED Fixtures
6 ft or 8 ft case
12 ft case
R
BL
R
BL
7
7
R
BL
5
BK
W
W
BL
R
G
Connector
Connector
BK
W
BK
W
BK
W
R
BL
R
BL
7
7
R
BL
R
BL
R
BL
7
7
R
BL
R
BL
BL
BL
(TYP)
Shelf Light
Plug & Receptacle
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves
R
R
BK
Top Eight (8) Shelf Hole Locations
18 in.
18 in.
14 in.
12 in.
Angle
Maximum
Shelf
Size
18 in.
Do NOT load
PRODUCT
above
this line
SHELF CONFIGURATION
This merchandiser is designed for one or two shelves.
The depth of the shelf used in the top eight (8) shelf hole locations is critical to case performance.
If a shelf is placed in one of the top eight (8) locations it must comply with the angle/depth requirements listed below.
Maximum Shelf
Shelf Angle Depth
0 º 12 in.
15 º 14 in.
or less
30 º 18 in.
or less
45 º 18 in.
or less
NOTE: Shelves placed in the lower positions may be up to 18 in. deep when positioned at a 0 º angle.
Impact
Excel
C2XEC-XE
Dairy/Delicatessen
Precut & Packaged Produce
11 of 12P/N 0489566_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
12 of 12
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2XEC-XE Technical Data Sheet
Impact
Excel
C2XEC-XE
Dairy/Delicatessen
Precut & Packaged Produce
Remove Screws
Light Channel
Light Channel
Hinge
Ballast
Light
Channel
Foil-covered Anti-sweat Heater
Canopy
Canopy
Anti-Sweat Heater Wires with Purple Markers
Electrical Wireway
The ballast for the canopy and shelf lamps is located behind the canopy on the left-hand end (when facing case) of the merchandiser.
To access the ballast:
1. Remove screws at bottom edge of canopy and rear of light channel.
2. Lower light channel which will pivot on hinge.
3. Service or replace ballasts as required.
4. Reassemble items as they were originally installed.
NOTE: Rail lamp ballast is located in the electrical raceway.
CANOPY ANTI-SWEAT HEATER
The canopy anti-sweat heater location is shown below. Connections are in the electrical wireway.
Loading...