Hussmann C2NX-XLGE Specifications

P/N0486795F
F
B
E
C
E
A
D
F
G
I
H
C2NX-XLGE
P/N 0486795_F
NSF
®
Certified
March 2009
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
6 Ft Only
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0382383 Fan Blade (FB.4780617) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0382383 Fan Blade (FB.4780617)
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
H
EATERS
D. Canopy Anti-Sweat Heater (4)
0512500
6 ft (HE.4851175) 0512501 8 ft (HE.4851176) 0512503
12 ft (HE.4851178
)
LAMPS AND BALLASTS
E. Ballast, Electronic (5)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
F. Fluorescent Lamp (6)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
G. 0501213 Power Supply (EP.4481861) (7) H. LED Canopy Fixture (8)
Replace with like fixtures — See Page 5.
I. LED Shelf Fixture (9)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision F adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
2 of 11
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2NX-XLGE Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy/Delicatessen
Precut & Packaged Produce
01-2005
Wireway
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
19
(483)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical Field Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/8 (1838) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) Back of case to O/S edge of front leg 25 1/
4 (641) 25
1
/
4 (641) 25
1
/
4 (641)
Distance between edges of external legs and center legs 29
1
/2 (750) 41 1/2 (1054) 41 1/2 (1054)
Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483) 19 (483) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
C2NX
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C2NX-XLGE
Discharge Air °F 29
Evaporator °F 21
Unit Sizing °F 19
Btu/hr/ft
— Unlit Shelves
‡‡
C2NX-XLGE
‡‡
Parallel Conventional
U
NLIT 970 1020
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft (4 ft, 6 ft and 8 ft
models) and 18 Btu/hr/ft (6 ft models). ‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C2NX-XLGE
Frequency (hr) 6
Defrost Water (lb/ft/day) 7
(±15% based on case configuration and product loading.
OFFTIME C2NX-XLGE
Temp Term °F 48°F
Failsafe Minutes 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2NX-XLGE
CI/CO* 14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** C2NX-XLGE
6 ft 1.6 lb 26 oz 0.7 kg
8 ft 2.3 lb 37 oz 1.0 kg
12 ft 3.3 lb 53 oz 1.5 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Dimensions shown as inches and (mm).
P/N 0486795_F 3 of 11
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
55 3/4
(1415)
26 3/4 (680)
4 3/4 (120)
25 1/4 (641)
37 (940)
28 1/2 (724)
21 1/4 (540)
C2NX-XLGE
25
(635)
18 1/2
(470)
FAN
C O
I
L
17 1/4
(438)
3 In. (77 mm)
Required
Air Gap
26 7/8
(683)
Electrical
Case to Case
Connections
12 1/4
(311)
Refrigeration
Outlet
3 5/8
(92)
29 3/4
(755)
31 1/4
(794)
3 3/4 (95)
6 (152)
7 1/4
(184)
Impact
Excel
C2NX-XLGE
Dairy/Delicatessen
Precut & Packaged Produce
Multi-deck, 4 Display Levels, Low Front with Glass, 55 In. Back, Narrow Footprint
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 10 for shelf arrangement.
4 of 11
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
C2NX-XLGE Technical Data Sheet
Electrical Data
6 ft 8 ft 12 ft Number of Fans—7W 2 3 Number of Fans—4W 2
Amperes Watts
6 ft 8 ft 12 ft 6 ft 8 ft 12 ft Evaporator Fan
120V 60Hz Standard 0.62 1.00 1.50 48 78 117
120V 50Hz Standard 0.76 1.10 1.65 54 84 126
230V 60Hz Export 0.30 0.50 0.75 48 78 117
230V 50Hz Export 0.36 0.56 0.84 54 84 126
120V 60Hz Energy Efficient 0.24 0.38 0.57 16 28 42
230V 60Hz Energy Efficient 0.12 0.20 0.30 16 28 42
Minimum Circuit Ampacity †
120V 60Hz Standard 0.82 1.20 1.70
120V 50Hz Standard 0.96 1.30 1.85
230V 60Hz Export 0.50 0.70 0.95
230V 50Hz Export 0.56 0.76 1.04
120V 60Hz Energy Efficient 0.44 0.58 0.77
230V 60Hz Energy Efficient 0.32 0.40 0.50
Maximum Over Current Protection 120V 20 20 20 Maximum Over Current Protection 230V 15 15 15
Anti-sweat Heaters
120V 50/60Hz Standard 0.15 0.20 0.30 12 18 24 36
Standard Lighting (T-8 Fluorescent)
1 Row Canopy 0.51 0.51 0.77 30 59 59 85
Optional Lighting (T-8 Fluorescent)
Additional 1 Row Canopy 0.51 0.51 0.77 30 59 59 85
1 Row Rail Light NA — Glass front does not accept rail light
3 Rows of Shelves 1.53 1.53 2.31 59 177 177 255
Optional EcoShine CRI (120VAC, 50/60Hz)
2 Row Canopy 0.41 0.55 0.82 49 66 98 2 Rows of Shelves 0.29 0.39 0.58 35 47 70
Optional EcoShine CRI (120VAC, 50/60Hz)
2 Row Canopy 0.47 0.63 0.93 56 75 112 2 Rows of Shelves 0.35 0.47 0.70 42 56 84
Optional Always*Bright LED Lighting
2 Row Canopy 0.55 0.71 1.08 66 85 130
2 Rows of Shelves 0.34 0.47 0.67 41 56 80
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
† MCA does not include Canopy A/S Heaters because heaters are wired separately from fans.
Impact