
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
®
C2-LGEP
Technical Data Sheet
P/N 0457228C
NSF
®
Certified
February 2006
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly (1)
0058698 Fan Motor, Evaporator
0142780 Fan Blade
embossing toward motor
B. 0137880 Optional Adjustable (2)
Refrigeration Thermostat
Item Part # Description Wiring Item #
HEATERS
C. Canopy Anti-Sweat Heater (3)
NA 4 ft
0109417 6 ft
0109417 8 ft
0109418 12 ft
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0376409 2 lamps
0376410 3 lamps
E. Fluorescent Lamp (5)
Replace with like fixtures
Note: Changes are NOT underlined.
Revision A added the canopy anti-sweat heater (pages 1,
4, 5 & 8); added 4-ft and 6-ft data (pages 1, 2, 3 & 4); and
updated wiring diagrams.
Revision B returned the correct data to page 3.
Revision C returned the correct data to page 1.
D
B
Merchandisers
C
E
D
E
E
A

2 of 8
C2-LGEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy / Delicatessen
Precut & Packaged
Produce
05-2003
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/4 (1226) 72 3/8 (1838) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/
2 in. (38 mm) to case line up.)
Maximum O/S dimension of case
back to front (includes bumper) 46 1/
2 (1182) 46
1
/
2 (1182) 46
1
/
2 (1182) 46
1
/
2 (1182)
Back of case to front of splashguard 38
7
/
8 (986) 38
7
/
8 (986) 38
7
/
8 (986) 38
7
/
8 (986)
Back of case to O/S edge of front skid rail 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140)
Distance between edges of external and center supports NA 31
1
/
8 (790) 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports 41
1
/
4 (1048) NA NA 44 (1118)
Stub-up area between front skid rail and splashguard 7
3
/
4 (199) 7
3
/
4 (199) 7
3
/
4 (199) 7
3
/
4 (199)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 38
1
/4 (972) 64 3/8 (1635) 88 3/8 (2245) 136 1/2 (3467)
Back O/S of case to center of knockout 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) 34 5/8 (881)
Length of electrical raceway 16 1/8 (410) 34 1/2 (876) 35 5/8 (903) 35 5/8 (903)
Waste Outlet
(C) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102)
Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NNoottee::
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230) 9 (230) 9 (230)
C2LGE
34 5/8
(881)
Elec.
72 1/4 (1835)
Skid/ External Base
7 3/4 (199)
A
B
C
D
Refrig.
29 1/4
(743)
30 5/8
(778)
38 7/8
(98 6)
46 1/2
(1182)
27
Waste Outlet
Water Seal
(see note)
Front
(703)
5
/8
4
(102)

REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
C2-LGEP U
NLIT LIT
Discharge Air (°F) 33 31
Evaporator (°F) 28 26
Unit Sizing (°F) 26 24
Btu/hr/ft* U
NLIT LIT
Parallel 545 610
Conventional 565 635
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
C2-LGEP
Frequency (hr) 12
Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
O
FFTIME
C2-LGEP
Time (minutes) 30
E
LECTRIC OR GAS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2-LGEP
CI/CO** 19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)7/8
Estimated Charge (lb)***
4 ft 1.5
6 ft 2.1
8 ft 2.7
12 ft 3.9
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 8
P/N 0457228C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
(Note* Optional Accessory Items)
19
(483)
3 3/4
(95)
12
(305)
30 1/8
(765)
(Note*)
18
(406)
(Note*)
C2LGEPLUS
48
(1219)
FAN
C
O
I
L
30
1
/4
(766)
(Note*)
7 3/4
(199)
27 5/8 (703)
29 1/4 (743)
30 5/8 (778)
34 5/8 (881)
38 7/8 (986)
46 1/2 (1182)
5 3/8
(136)
(Note*)
14 1/8
(359)
26
(661)
6 1/8
(155)
Dimensions shown as inches and (mm).
Multi-deck, 3 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF ®) Standard #7 requirements.
Impact C2-LGEP
Dairy / Delicatessen
Precut & Packaged Produce
C2-LGEP