Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly (1)
0058698 Fan Motor, Evaporator 0142780 Fan Blade
embossing toward motor
B. 0137880 Optional Adjustable (2)
Refrigeration Thermostat
Item Part # Description Wiring Item #
HEATERS
C. Canopy Anti-Sweat Heater (3)
NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0376409 2 lamps 0376410 3 lamps
E. Fluorescent Lamp (5)
Replace with like fixtures
Note: Changes are NOT underlined. Revision A added the canopy anti-sweat heater (pages 1, 4, 5 & 8); added 4-ft and 6-ft data (pages 1, 2, 3 & 4); and updated wiring diagrams. Revision B returned the correct data to page 3. Revision C returned the correct data to page 1.
D
B
Merchandisers
C
E
D
E
E
A
2 of 8
C2-LGEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy / Delicatessen
Precut & Packaged
Produce
05-2003
4 ft 6 ft 8 ft 12 ft
General (A) Case Length (without ends or partitions) 48 1/4 (1226) 72 3/8 (1838) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/
2 in. (38 mm) to case line up.)
Maximum O/S dimension of case
back to front (includes bumper) 46 1/
2 (1182) 46
1
/
2 (1182) 46
1
/
2 (1182) 46
1
/
2 (1182)
Back of case to front of splashguard 38
7
/
8 (986) 38
7
/
8 (986) 38
7
/
8 (986) 38
7
/
8 (986)
Back of case to O/S edge of front skid rail 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140)
Distance between edges of external and center supports NA 31
1
/
8 (790) 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports 41
1
/
4 (1048) NA NA 44 (1118)
Stub-up area between front skid rail and splashguard 7
3
/
4 (199) 7
3
/
4 (199) 7
3
/
4 (199) 7
3
/
4 (199)
Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of farthest knockout 38
1
/4 (972) 64 3/8 (1635) 88 3/8 (2245) 136 1/2 (3467) Back O/S of case to center of knockout 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) Length of electrical raceway 16 1/8 (410) 34 1/2 (876) 35 5/8 (903) 35 5/8 (903)
Waste Outlet (C) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NNoottee::
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230) 9 (230) 9 (230)
C2LGE
34 5/8
(881)
Elec.
72 1/4 (1835)
Skid/ External Base
7 3/4 (199)
A
B
C
D
Refrig.
29 1/4
(743)
30 5/8
(778)
38 7/8
(98 6)
46 1/2
(1182)
27
Waste Outlet
Water Seal
(see note)
Front
(703)
5
/8
4
(102)
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
C2-LGEP U
NLIT LIT
Discharge Air (°F) 33 31 Evaporator (°F) 28 26 Unit Sizing (°F) 26 24
Btu/hr/ft* U
NLIT LIT
Parallel 545 610 Conventional 565 635
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
C2-LGEP Frequency (hr) 12 Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
O
FFTIME
C2-LGEP Time (minutes) 30
E
LECTRIC OR GAS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2-LGEP
CI/CO** 19°F / 9°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)7/8
Estimated Charge (lb)*** 4 ft 1.5 6 ft 2.1 8 ft 2.7 12 ft 3.9
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 8
P/N 0457228C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
(Note* Optional Accessory Items)
19
(483)
3 3/4
(95)
12
(305)
30 1/8
(765)
(Note*)
18
(406)
(Note*)
C2LGEPLUS
48
(1219)
FAN
C O
I
L
30
1
/4
(766)
(Note*)
7 3/4
(199)
27 5/8 (703)
29 1/4 (743)
30 5/8 (778)
34 5/8 (881)
38 7/8 (986)
46 1/2 (1182)
5 3/8
(136)
(Note*)
14 1/8
(359)
26
(661)
6 1/8
(155)
Dimensions shown as inches and (mm).
Multi-deck, 3 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ®) Standard #7 requirements.
Impact C2-LGEP
Dairy / Delicatessen
Precut & Packaged Produce
C2-LGEP
Loading...
+ 5 hidden pages