4 of 8 C2-LGE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact C2-LGE
Dairy / Delicatessen
Precut & Packaged Produce
Electrical Data
4 ft 6 ft 8 ft 12 ft
Number of Fans 1 2 2 3
Amperes Watts
4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Evaporator Fan
120V 60Hz Standard 0.51 1.00 1.00 1.50 38 78 78 117
120V 50Hz Standard 0.55 1.10 1.10 1.65 42 84 84 126
230V 60Hz Export 0.25 0.50 0.50 0.75 40 80 80 120
230V 50Hz Export 0.28 0.56 0.56 0.84 44 88 88 132
120V 60Hz Energy Efficient 0.26 0.52 0.52 0.78 18 36 36 54
230V 60Hz Energy Efficient NA
Canopy Anti-sweat Heaters NA 0.75 0.75 1.00 45 90 90 120
Minimum Circuit Ampacity
120V 60Hz Standard 0.71 1.95 1.95 2.70
120V 50Hz Standard 0.75 2.05 2.05 2.85
230V 60Hz Export 0.45 1.45 1.45 1.95
230V 50Hz Export 0.48 1.51 1.51 2.04
120V 60Hz Energy Efficient 0.46 1.47 1.47 1.98
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15
Standard Lighting
1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Optional Lighting
Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170
1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85
1 Row Ledge Light 0.26 0.51 0.51 0.77 30 59 59 85
Optional Shelf Lighting
1 Row Shelf Receptacle 0.26 0.51 0.51 0.77 30 59 59 85
2 Row Shelf Receptacle 0.51 1.02 1.02 1.53 59 118 118 177
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52