Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly (1)
0058698 Fan Motor, Evaporator 0142780 Fan Blade
embossing toward motor
B. 0311588 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
HEATERS
D. Canopy Anti-Sweat Heater (4)
NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft
L
AMPS AND
BALLASTS
E. Ballast, Electronic (5)
0376409 2 lamps 0376410 3 lamps
F. Fluorescent Lamp (6)
Replace with like fixtures
Revision C corrects statistical data on Page 3.
Merchandisers
E
C
F
B
D
E
F
F
A
2 of 8 C2-LGE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Dairy / Delicatessen
Precut & Packaged
Produce
05-2003
4 ft 6 ft 8 ft 12 ft
General (A) Case Length (without ends or partitions) 48 1/
4 (1226) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case
back to front (includes bumper) 46 1/2 (1182) 46 1/2 (1182) 46 1/2 (1182) 46 1/2 (1182) Back of case to front of splashguard 38 7/8 (986) 38 7/8 (986) 38 7/8 (986) 38 7/8 (986) Back of case to O/S edge of front skid rail 29 1/4 (743) 29 1/4 (743) 29 1/4 (743) 29 1/4 (743) Width of skid rail 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) RH end of case to outside edge of external support 5 1/2 (140) 5 1/2 (140) 5 1/2 (140) 5 1/2 (140) Distance between edges of external and center supports NA 31 1/8 (790) 40 5/8 (1032) 40 5/8 (1032) Distance between edges of center supports 41 1/4 (1048) NA NA 44 (1118) Stub-up area between front skid rail and splashguard 7 3/4 (199) 7 3/4 (199) 7 3/4 (199) 7 3/4 (199)
Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of farthest knockout 38 1/4 (972) 64 3/8 (1635) 88 3/8 (2245) 136 1/2 (3467)
Back O/S of case to center of knockout 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) Length of electrical raceway 16 1/8 (410) 34 1/2 (876) 35 5/8 (903) 35 5/8 (903)
Waste Outlet (C) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NNoottee::
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230) 9 (230) 9 (230)
C2LGE
34 5/8
(881)
Elec.
72 1/4 (1835)
Skid/ External Base
7 3/4 (199)
A
B
C
D
Refrig.
29 1/4
(743)
30 5/8
(778)
27
Waste Outlet
Water Seal
(see note)
Front
(703)
5
/8
4
(102)
38 7/8
(98 6)
46 1/2
(1182)
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
C2-LGE
Discharge Air (°F) 27
Evaporator (°F) 21
Unit Sizing (°F) 19
Btu/hr/ft* C2-LGE
Parallel 955
Conventional 1050
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
C2-LGE Frequency (hr) 6 Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
OFFTIME C2-LGE
Temp Term (°F) 48°F Failsafe (minutes) 30
E
LECTRIC OR G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2-LGE
CI/CO** 17°F / 7°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)7/
8
Estimated Charge (lb)*** 4 ft 1.3 6 ft 1.8 8 ft 2.3 12 ft 3.3
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 8
P/N 0397201C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
6 1/8
(155)
(Note:* Optional Accessory Items)
19
(483)
3 3/4
(95)
12
(305)
30 1/8
(765)
(Note*)
18
(406)
(Note*)
C2LGE
48
(1219)
FAN
C
O
I
L
30
1
/4
(766)
(Note*)
26
(661)
7 3/4
(199)
27 5/8 (703)
29 1/4 (743)
30 5/8 (778)
34 5/8 (881)
38 7/8 (986)
46 1/2 (1182)
5 3/8
(136)
(Note*)
14 1/8
(359)
Dimensions shown as inches and (mm).
Multi-deck, 3 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ®) Standard #7 requirements.
Impact C2-LGE
Dairy / Delicatessen
Precut & Packaged Produce
C2-LGE
4 of 8 C2-LGE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact C2-LGE
Dairy / Delicatessen Precut & Packaged Produce
Electrical Data
4 ft 6 ft 8 ft 12 ft
Number of Fans 1 2 2 3
Amperes Watts
4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Evaporator Fan
120V 60Hz Standard 0.51 1.00 1.00 1.50 38 78 78 117
120V 50Hz Standard 0.55 1.10 1.10 1.65 42 84 84 126
230V 60Hz Export 0.25 0.50 0.50 0.75 40 80 80 120
230V 50Hz Export 0.28 0.56 0.56 0.84 44 88 88 132
120V 60Hz Energy Efficient 0.26 0.52 0.52 0.78 18 36 36 54
230V 60Hz Energy Efficient NA
Canopy Anti-sweat Heaters NA 0.75 0.75 1.00 45 90 90 120
Minimum Circuit Ampacity
120V 60Hz Standard 0.71 1.95 1.95 2.70
120V 50Hz Standard 0.75 2.05 2.05 2.85
230V 60Hz Export 0.45 1.45 1.45 1.95
230V 50Hz Export 0.48 1.51 1.51 2.04
120V 60Hz Energy Efficient 0.46 1.47 1.47 1.98
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15
Standard Lighting
1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Optional Lighting
Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170
1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85
1 Row Ledge Light 0.26 0.51 0.51 0.77 30 59 59 85
Optional Shelf Lighting
1 Row Shelf Receptacle 0.26 0.51 0.51 0.77 30 59 59 85
2 Row Shelf Receptacle 0.51 1.02 1.02 1.53 59 118 118 177
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52
5 of 8P/N 0397201C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
1, 2 & 3 Fans
4 ft 6 ft 8 ft
12 ft
Fan Wiring
Offtime Defrost
120V NEUTRAL
ROWN BAND
120V POWER
BROWN BAND
120V Power
Purple BAND
Fans
4
Anti-Sweat Heater
1
B
120V Neutral
Purple BAND
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
G
R
BL
Connector
W
G
G
Connector
W
G
B
120 V Powe r
Connector
G
B
W
5
BL
R
BL
BL
Defrost
Ter mination
2
Thermostat
Dark Blue
Refrigeration
3
Thermostat
Light Blue
To Condensing
}
Unit
Canopy
Anti-Sweat Heater
Shelf Lighting
R
Connector
Connector
BL
G
G
BL
R
G
R
BL
Connector
B
G
BL
R
Shelf Light Circuits
BL
Connector
G
Connector
G G
R
BL
6
R
6
Connector
BL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= 120V P
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
OWER = 120V NEUTRAL = Field GROUND
= Case G
ROUND
R
6
6 of 8 C2-LGE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
5
R
BL
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
B
5
W
5
BL
BL
BL
BL
66
R
R
BL
6
BL
R
BL
R
6
BL
R
66
R
6
R
6
R
6
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL
7 of 8P/N 0397201C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
SHELF CONFIGURATION
This merchandiser is designed for one or two shelves.
The depth of the shelf used in the top eight (8) shelf hole locations is critical to case performance.
If a shelf is placed in one of the top eight (8) locations it must comply with the angle/depth requirements listed below.
Maximum Shelf
Shelf Angle Depth
0 º 12 in.
15 º 14 in.
or less
30 º 18 in.
or less
45 º 18 in.
or less
NOTE: Shelves placed in the lower positions may be up to 18 in. deep when positioned at a 0 º angle.
Impact C2-LGE
Dairy / Delicatessen
Precut & Packaged Produce
Angle
15°
Top Eight (8) Shelf Hole Locations
Maximum
Shelf
Size
12 in.
14 in.
30°
45°
18 in.
18 in.
18 in.
C2-LGE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
8 of 8
Impact C2-LGE
Dairy / Delicatessen Precut & Packaged Produce
CANOPY AND SHELF LAMP BALLAST
The ballast for the canopy and shelf lamps is located behind the canopy on the left-hand end (when facing case) of the merchandiser.
To access the ballast:
1. Remove screws at bottom edge of canopy and rear of top panel.
2. Remove the one piece canopy top panel by moving panel forward slightly to clear flange in front then lifting up.
3. Service or replace ballasts as required.
4. Reassemble items as they were originally installed.
NOTE: Rail lamp ballast is located behind the lower front panel.
CANOPY ANTI-SWEAT HEATER
The canopy anti-sweat heater location is shown below. Connections are in the Electrical wireway.
Screws
Screws
Ballast
Canopy
Foil-covered Anti-sweat Heater
Electrical Wireway
Canopy
Anti-Sweat Heater Wires with Purple Markers
Loading...