Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 4W Fan Assembly (1)
0392457 Fan Motor, Evaporator (MO.4410101)
0409511 Fan Blade (FB.0409511)
embossing toward motor
B. 0382028 Standard Non-adjustable (2)
Defrost Thermostat (CT.0382028)
C. 0253451 Optional Adjustable (3)
Refrigeration Thermostat
(CT.4480780)
Item Part # Description Wiring Item #
HEATERS
D. 0401556 Nosing Anti-Sweat Heater, 6 ft (4)
(HE.4850466)
LAMPS AND BALLASTS
E. 0428648 Ballast, Electronic, 2 lamps (5)
(BA.4480823)
F. Fluorescent Lamp (6)
Replace with like fixtures
C1CWCEI
Technical Data Sheet
P/N 0454706_A
NSF
®
Certified
March 2007
Shown with
Standard
Light Bar
©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision A corrects illustration on Page 1 and plan view on Page 2.
B
Merchandisers
E
F
Bulb
Location
C
D
A

6 ft
General
Case Length (including ends) 74 1/8 (2448)
Optional End Bumpers (One pair) 2 (51)
Maximum O/S dimension of case back to front (including bumper) 49 (1245)
Back of case to front of splashguard 31 7/8 (810)
Center of rear legs to center of front legs 23 1/2 (597)
Electrical Service (Electrical Field Wiring connection point)
Right-hand of case to center of knockout 34 (863)
Back of case to center of knockout 10 (254)
Length of electrical raceway 31 5/8 (803)
Waste Outlet
Right-hand end of case to the center of waste outlet 25 (636)
Back outside of case to center of waste outlet 28 (711)
Water Seal
Edge of water seal to center of waste outlet 4 (102)
Outside diameter of the drip pipe 1 1/2 (38)
Refrigeration Outlet
Back of case to center of refrigeration outlet 31 (787)
Right-hand end of case to center of refrigeration outlet 10 (254)
2 of 6 C1CWCEI Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Prepackaged
Meat &
Delicatessen
09-2003
7
/8
6
(174)
23 1/2
(597)
74 1/8 (1883)
1
/2
8
1
1
/2 (38)
Electrical
Legs
Waste Outlet
(216)
Refrigeration Outlet
65 1/4 (1658)
Front
34 (863)
25 (636)
10
(254)
C1CWCEI
10
(254)
28
(711)
4 1/2
(114)
6 Ft
31
(787)
49
(1245)

3 of 6
P/N 0454706_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact C1CWCEI
Prepackaged Meat &
Delicatessen
Dimensions shown as inches and (mm).
Single Deck End Case, Wood Clad
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF®) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
C1CWCEI
Discharge Air °F 29
Evaporator °F 18
Unit Sizing °F 16
Btu/hr/ft C1CWCEI
Parallel 422
Conventional 453
DEFROST DATA
Frequency Hrs 12
Defrost Water (lb/ft/day) 0.2
(± 15% based on case configuration and
product loading).
OFFTIME C1CWCEI
Temp Term °F 48
Failsafe Minutes 90
E
LECTRIC OR GAS
No
Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* 11°F / 1°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Estimated Charge (lb)** C1CWCEI
6 ft 1.5
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by Each
End or Insulated Partition (in.) N/A
C1CWCEI
37
(938)
with
Standard
Light Bar
33 3/8
(76)
3
31 1/4
(793)
25 1/4
(642)
15 1/2
(393)
49
(1245)
11 3/4
(298)
59 1/2
(1511)
58 1/4
(1479)
(849)
20 1/8
(511)
26 3/4
(680)
COIL
26 3/8
(670)
15 5/8
(396)
5 1/8
1 1/2
41
(1042)
(132)
(38)
FAN

4 of 6 C1CWCEI Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact C1CWCEI
Prepackaged Meat &
Delicatessen
Electrical Data
Number of Fans 6 ft
Refrigeration – 9W 4
Export – 9W NA
Amperes Watts
Merchandiser 6 ft 6 ft
Fans (Refrigeration)
120V 60Hz Standard 0.62 48
120V 60Hz Energy Efficient NA NA
230V 50Hz Export NA NA
Constant On Anti-sweat Heaters 0.2 24
Minimum Circuit Ampacity
120V 60Hz Standard 0.9
120V 60Hz Energy Efficient NA
230V 50Hz Export NA
Maximum Over Current Protection 120V 20
230V 50Hz Export NA
208V Electric Defrost Heaters NA NA
208V Gas Defrost Heaters NA NA
Standard Lighting
Light Bar 6 ft 6 ft
1 Row 0.51 62

5 of 6P/N 0454706_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Fan Wiring
Offtime Defrost
2 Fans
120V POWER
BROWN BAND
120V NEUTRAL
1
Fans
BROWN BAND
Heaters
4
2
Termination
Thermostat
Defrost
Dark Blue
Refrigeration
3
Thermostat
Light Blue
To
Condensing
}
Unit
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL
= FIELD GROUND
= CASE GROUND

6 of 6 C1CWCEI Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting for Light Bar — 1 Row
120V N
EUTRAL
O
RANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
Ballast Feed Harness
W
Ballast Jumper Harness
G
B
W
G
B
W
G
B
5
BL
R
BL
6
R
6
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
C
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER
= 120V NEUTRAL