Hussmann BEXD-A Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Merchandisers
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. Fan Motor, Evaporator (1)
0392457 Standard NA Energy Efficient 0409511 Fan Blade
B. 0261933 Standard Adjustable (2)
Refrigeration Thermostat
H
EATERS
C. 0401605 Nosing Anti-sweat Heater (3) D. 0322013 Evaporator Pan Heater (4)
Item Part # Description Wiring Item #
C
ONTROL PANEL
E. 0106236 Defrost Timer (5)
F. 0019187 Disconnect Switch (6) G. 0138400 Contactor (7) H. 0394263 Pressure Control (8)
I 0126065 Fuse (9)
R
EFRIGERATION
J. 0433426 Condensing Unit Assembly
K. 0403865 TEV
L. 0331344 Sight Glass
M. 0111482 Drier
Note: Changed items have been underlined.
P/N 0441384A
BEXD-A
Data Sheet Set
P/N 0441384A
NSF
®
Certified
August, 2003
®
Control
Panel
Access
E
F
GH I
Condensing
Unit
Access
KLM
J
Page 2
BEXD Data Sheet Set2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
BEXD-A
Bakery, Self-Contained
Dimensions shown as in. and (mm).
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (Note: Includes One Pair Ends) 99 1/4 (2448)
Optional End Bumpers
(One Pair) 2 (51)
Maximum O/S dimension of case back to front 53
3
/8 (1357)
(Note: Includes bumper)
Back of case to front of splashguard 45 3/4 (1161) — Center of rear legs to center of front legs 25
5
/8 (651)
Waste Outlet
(B) RH end of case to center of waste outlet 19
5
/8 (499)
101 1/4 (2573)
99 1/4 (2522)
10 3/8
(263)
39 7/8
(1012)
44 3/8
(1127)
50 1/8
(1274)
45 3/4
(1161)
53 3/8
(1357)
Electrical Plug Access
Control Panel
Access
Front
C
L
Evaporator Pan
Waste Outlet
Access
Airflow Direction
Condensing Unit
19 5/8
(499)
Page 3
3 of 6P/N 0441384A
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
43 3/4 (1114)
9 1/4
(234)
45 3/4 (1161)
44 3/8 (1127)
COIL
FAN
16
3
/4
(424)
18
(456)
10 3/4
(277)
53 1/2 (1350)
43 1/4
(1040)
35
(890)
BEXD
Impact BEXD-A
Bakery, Self Contained
Dimensions shown as in. and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H. Schedule defrost at night while lights are off.
BEXD
4 ft 5 ft 8 ft 12 ft
Discharge Air (°F)
——
15
Evaporator (°F) —— 11
Btu/hr/case ——
4528
DEFROST DATA
BEXD Frequency (hr) 12 Defrost Water(lb/ft/day) NA
(± 15% based on case configuration and
product loading).
OFFTIME
Failsafe (minutes) 70
E
LECTRIC OR GAS Not A vailable
Standard Defrost Thermostat NA
CONVENTIONALCONTROLS
Low Pressure Backup Control
BEXD CI/CO (Temp °F)** 30°/20°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)** 48°
**Use a Temperature Pressure Chart to determine PSIG conversions.
BEXD PHYSICAL DATA
Drip Pipe (in.)
5
/8
Liquid Line (in.)
3
/
8
Suction Line (in.)
7
/8
Estimated Charge (lb)
4 ft 6 ft
8 ft
5.5
12 ft
Length Added to Lineup by: Each Plastic End
w/ Bumper (in.) 3
1
/2
Each End 1 1/
2
NOTE: The bumper is 4 in. (102 mm) wide. Center of the
bumper is 18 in. (456 mm) from the floor.
Self-Contained, 1 Display Level
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
Page 4
BEXD Data Sheet Set4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact BEXD-A
Bakery, Self-Contained
Electrical Data
Number of Fans 4 ft 6 ft 8 ft 12 ft
Refrigeration – 4W —— 2 —
120V/60hz System
Export – 9W ——NA—
(Export: 230V 50 hz shown)
Amperes Watts
Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Fans
Standard — 0.58 48 — Energy Efficient NA NA — Export: 230V 50 hz NA NA
Nosing Anti-sweat Heaters (120V) 0.67 80
Evaporator Pan Heaters (120V) 4.0 460
Minimum Circuit Ampacity
With Standard Fans 14.8 — With Energy Efficient Fans NA — With Export: 230V 50 hz Fans NA
Maximum Over Circuit Protection 120V ——20
Condensing Unit
Minimum Circuit Ampacity 9.5 — Compressor LRA 33.5 — Compressor RLA 6.7
Lighting
Standard 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
None NA NA
Optional
None NA NA
Page 5
5 of 6P/N 0441384A
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Anti-Sweat Heater
Control Panel
4
4
Heater
1
X
3
M
5
Timer
Ground
3
1
Evaporator Fan
Black
8
1
Evaporator Fan
Thermostat
Dual Pressure Control
2
30A Contactor
2
N
4
C
1
2
3
1
2
3
Fuse Each Line
9
15A
15A
Fuse Block
Black
Black
7
6
Control Box
Disconnect Switch
BBW
208 / 230 / 1 / 60
4 Wire
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
C
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
to
Te r mi na l
Board
Page 6
BEXD Data Sheet Set6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Condensing Unit
Terminal Board
(diagram for information only —
board not manufactured by Hussmann)
Typical Condensing Unit
Condenser Fan
to
Control
Panel
Black
Black
Compressor Terminal Block
Yellow
Terminal Board
START CAP
C
S
Red
C
Black
R
R
2
3
Blue
Black
Black
1
Yellow
S
CURRENT RELAY
1
2
5
Protector
Yellow
UNIT 1HP
208 / 230 / 1 / 60
RUN CAP