Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator – 120V
(MO.4410101)
0409511 Fan Blade (FB.0409511)
A. 4W Energy Efficient Fan Assembly (1)
0477653 Fan Motor, Evaporator – 120V
(MO.4410544)
0409511 Fan Blade (FB.0409511)
B. 0510349 Standard Adjustable (2)
Refrigeration Thermostat
(CT.4441543)
Item Part # Description Wiring Item #
HEATERS
C. Nosing Anti-sweat Heater, 120V (3)
0496493 8 ft (HE.4850736)
LAMPS AND BALLASTS (IN OPTIONAL LIGHT BAR)
D. Ballast, Electronic (4)
0466234 2 lamps (BA.4480823)
E. Fluorescent Lamp (5)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
C
M
D
Shown with
Optional
Light Bar
A
B
Revision A is original issue.
P/N_0518264_A
BEXD
Technical Data Sheet
P/N 0518264_A
NSF
®
Certified
November 2010
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

BEXD Technical Data Sheet2 of 6
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Waste Outlet
Refrigeration
Outlet
Water Seal
Access Area (Gray)
Front
Base Rail
29 1/2
(749)
44 3/8
(1127)
46 1/2
(1181)
38 7/8
(987)
41 5/8
(1057)
50 3/4
(1335)
53 1/2
(1359)
5 1/2
(140)
1 1/4
(32)
A
B
C
Splashguard
Wireway
BEXD
11-2010
Dimensions shown as in. and (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Engineering
Plan Views
8 ft
General
(A) Case Length (without ends or partitions) 96 1/4 (2445)
(each end or insulated partition adds 1 1/2 in. [38 mm]; each end with bumper adds 2 1/2 in. [64 mm])
Maximum O/S dimension back to front (with bumper) 53 1/
2 (1359)
Back of case to front of splashguard 45
3
/
4 (1162)
Back of case to O/S edge of front skid rail 38
3
/4 (984)
Width of skid rail 4 1/
4 (108)
RH end of case to outside edge of external support 1
3
/
8 (35)
Distance between edges of external support and center support 44
5
/8 (1135)
Stub-up area between front skid rail and splashguard 4 5/8 (117)
Electrical Service (Electrical Field Wiring connection point)
Length of electrical raceway 32 3/4 (831)
(B) RH End of case to center of farthest knockout 89 1/4 (2267)
Back of case to center of knockout 46
1
/2
(1181)
RH End of case to RH end of raceway 57
1
/2 (1460)
Waste Outlet
(C) RH End of case to the center of waste outlet 19 5/8 (498)
LH End of case to the center of waste outlet 76 5/
8 (1946)
Back O/S of case to center of waste outlet 44
3
/8 (1127)
Water Seal
Edge of water seal to center of waste outlet 13 (330)
Outside diameter of the drip pipe 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 41 5/8 (1057)
RH end of case to center of refrigeration outlet 5 1/
2 (140)

53 1/8
(1350)
16 5/8
(422)
35
1
/8
(892)
18
(456)
43 3/4 (1111)
10 7/8 (276)
7 1/4
(184)
22 1/4 (565)
2 5/8 (67)
Optional
Light Bar
FAN
COIL
41
(1042)
2
1
/8
(54)
10
3
/
8
(263)
44 3/8 (1127)
45 3/4 (1162)
53 1/2 (1359)
41 5/8 (1057)
Refrigeration Outlet
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H. Schedule defrost at night while lights
are off.
BEXD
Discharge Air (°F) 31
Evaporator (°F) 21
Unit sizing (°F) 19
Btu/hr/ft
‡
BEXD
Parallel 460
Conventional 490
‡
Optional energy efficient motors reduce the refrig-
eration load by 14 Btu/hr/ft.
DEFROST DATA
BEXD
Frequency (hr) 12
Defrost Water (lb/ft/day) 2
(± 15% based on case configuration and product
loading).
O
FFTIME
Failsafe (minutes) 70
E
LECTRIC OR G
AS
Not Available
Standard Defrost Thermostat NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
BEXD
CI/CO* 30°F/20°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge** BEXD
8 ft 2.7 lb 43 oz 1.2 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately 0.5 lb (8 oz / 0.2 kg).
3 of 7
P/N 0518264_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Excel BEXD
Bakery
Dimensions shown as in. and (mm).
Single Deck, Extended Depth, Self-Service
NSF®Certification
This merchandiser is manufactured to meet ANSI/NSF
®
(National
Sanitation Foundation) Standard #7 requirements for construction,
materials & cleanability.
11-2010
BEXD

BEXD Technical Data Sheet4 of 6
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Excel BEXD
Bakery
Electrical Data
8 ft
Number of Fans – 4W 2
Amperes Watts
8 ft 8 ft
Evaporator Fans
120V 60Hz Standard 0.62 48
120V 60Hz Energy Efficient 0.24 16
120V 60Hz Export NA
Nosing Anti-sweat Heaters (120V) 0.67 80
Minimum Circuit Ampacity
120V 60Hz Standard 1.49
120V 60Hz Energy Efficient 1.11
120V 60Hz Export NA
Maximum Over Circuit Protection 120V 20
Lighting
Standard 8 ft 12 ft 8 ft
Optional Light Bar
1 Row Fluorescent Lamp 0.50 60

5 of 7
P/N 0518264_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Excel BEXD
Bakery
ESTIMATED SHIPPING WEIGHT
4
Case
8 ft End
lb (kg) 800 (363) 75 (43)
4
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube 1 (Cu Ft/Ft) 2.85 ft3 /ft (0.26 m3/m)
ARI Total Display Area 2 (Sq Ft/Ft) 3.77 ft2 /ft (1.15 m2 /m)
Shelf Area 3(Sq Ft/Ft) 3.77 ft2 /ft (1.15 m2 /m)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume / Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2] / Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product
Reference Guide. The standard shelf complement for this model is NONE.

BEXD Technical Data Sheet6 of 7
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Anti-Sweat Heater
(Rear Rail)
3
1
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
8 ft
2 Fans
Light Blue
2
To
Condensing
Unit
}
Refrigeration Thermostat
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120VPOWER
= 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost

7 of 7
P/N 0518264_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4
5
120V
N
EUTRAL
Light
Switch
120V
P
OWER
R
G G
BL
BL
BLR
BK
G
R
5
ORANGE OR TAN BAND
W
Typical Ballast Wiring
Maximum lamps per ballast is three (3).
Different case lengths will have more lamp ballasts.
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120VP
OWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS