EZ WIRE INSTALLATION INSTRUCTIONS
1
INSTALLATION RECOMMENDATIONS
Floor Anchors (part #H5814 in post kit. ½” x 4
1/4”) Post Shims (Part #H5820 in post kit) INCLUDED
Floor Anchors (part #H5814 in post kit. ½” x 4
1/4”) Post Shims (Part #H5820 in post kit) INCLUDED
Tools Recommended:
• Safety ladder (most jobs too tall to reach from floor)
• Carpenter Level
• Chalk line
Tools Required
• 1/2” Masonry bit (drill holes in floor for post)
• 1/2” wrench or socket (screws for door to the post)
• ¾” wrench or socket (for anchor bolts)
• Small hammer (to insert drive pins)
Parts Recommended:
• Drill Bits (various)
• Tape measure
• Safety Items (hardhat, gloves, safety glasses & steel toe work shoes); remove jewelry
Prior to installation:
• Prior to beginning installation please check bill of lading to make sure that you have all the parts required for the assembly
• Make sure that the installation area is clear of all obstructions
• Read thoroughly all the instructions pertinent to your installation
• The following installation instructions should be used as a guide for installing Husky Rack & Wire EZ WIRE products. Good common
sense and appropriate safety precautions must be used during installations. The product may be unstable during installation;
temporary bracing should be used until all hardware is tightened and the product is properly anchored to the floor. Permanent field
bracing (NOT SUPPLIED) may be installed. Call Factory if installation help is needed. Installation problems arising from job site
conditions should be referred to a professional installer. Refer product assembly questions to Husky Rack & Wire. 800-438-5629.
• D
O NOT CLIMB FENCE DURING OR AFTER INSTALLATION
2
PANEL/POST ARRANGEMENTS
• Use a chalk-line to mark the partition
runs on the floor.
• Starting with a Line Post, lag the post
to the floor using two floor anchors.
(the line post is 2 ½” square tube
with 2 ½” x 7 ½” footplate welded to
it). Make sure the slots are facing
• Stand up another Line post at a
distance of width of the panel to be
installed. (Distance between in the
post = Nominal width of the Panel – 2
3/8”). For 8’ panel, distance between
the post is 96”-2 3/8” = 93 5/8”
• Pick up the panel and install the
hooks in the slots of the line post.
Install bottom panel first.
• Install top panel and fasten to the
post using drive pins.
• EZ Wire panels are installed from the inside of the cage.
3
PANEL/POST ARRANGEMENTS
• Install one drive pin per
hook for maximum
security.
•
hole
• Tap on the extended pin
Inside of
the cage
DRIVE
PIN
using hammer until it is
flush with the cap part
of the drive pin.
4
CORNER POST APPLICATION
• Corner post are used for
turning corner at 90
degrees.
•
installed as an Inside
Corner or Outside
Corner.
Inside