EZ WIRE INSTALLATION INSTRUCTIONS
1
INSTALLATION RECOMMENDATIONS
Floor Anchors (part #H5814 in post kit. ½” x 4
-
1/4”) Post Shims (Part #H5820 in post kit) INCLUDED
Floor Anchors (part #H5814 in post kit. ½ x 4
-
1/4) Post Shims (Part #H5820 in post kit) INCLUDED
Tools Recommended:
Safety ladder (most jobs too tall to reach from floor)
Carpenter Level
Chalk line
Tools Required
1/2” wrench or socket (screws for door to the post)
¾” wrench or socket (for anchor bolts)
Small hammer (to insert drive pins)
Parts Recommended:
Drill Bits (various)
Tape measure
Safety Items (hardhat, gloves, safety glasses & steel toe work shoes); remove jewelry
Prior to installation:
Prior to beginning installation please check bill of lading to make sure that you have all the parts required for the assembly
Make sure that the installation area is clear of all obstructions
Read thoroughly all the instructions pertinent to your installation
The following installation instructions should be used as a guide for installing Husky Rack & Wire EZ WIRE products. Good common
sense and appropriate safety precautions must be used during installations. The product may be unstable during installation; temporary bracing should be used until all hardware is tightened and the product is properly anchored to the floor. Permanent field bracing (NOT SUPPLIED) may be installed. Call Factory if installation help is needed. Installation problems arising from job site conditions should be referred to a professional installer. Refer product assembly questions to Husky Rack & Wire. 800-438-5629.
D
O NOT CLIMB FENCE DURING OR AFTER INSTALLATION
2
PANEL/POST ARRANGEMENTS
inside of the cage.
inside of the cage.
Use a chalk-line to mark the partition runs on the floor.
Starting with a Line Post, lag the post to the floor using two floor anchors. (the line post is 2 ½” square tube with 2 ½” x 7 ½” footplate welded to it). Make sure the slots are facing
Stand up another Line post at a distance of width of the panel to be installed. (Distance between in the post = Nominal width of the Panel – 2 3/8”). For 8’ panel, distance between the post is 96”-2 3/8” = 93 5/8”
Pick up the panel and install the hooks in the slots of the line post. Install bottom panel first.
Install top panel and fasten to the post using drive pins.
EZ Wire panels are installed from the inside of the cage.
3
PANEL/POST ARRANGEMENTS
Put drive pin into the
Put drive pin into the
Install one drive pin per hook for maximum security.
hole
Tap on the extended pin
Inside of the cage
DRIVE PIN
using hammer until it is flush with the cap part of the drive pin.
4
CORNER POST APPLICATION
Corner post can be
Corner post can be
Corner post are used for turning corner at 90 degrees.
installed as an Inside Corner or Outside Corner.
Inside Corner