purchasing a Parkray Aspect stove. This stove was designed and
built to be a high-performance heating appliance, and we hope
it will bring you great enjoyment. The natural environment is
important to us, so our stoves are manufactured to provided you
with a clean and efcient burn that will keep you warm through
cold winter nights.
CONTENTS INDEX
STOVE INFORMATION
GENERAL INFORMATION 4/5
MATERIAL CLEARANCES 6
GENERAL GUIDANCE 7 - 10
OPERATING INSTRUCTIONS 11/12
MAINTENANCE AND SERVICING 13 - 14
3
IMPORTANT INFORMATION 15/16
TROUBLESHOOTING 17
WARRANTY INFORMATION 18/19
STOVE INFORMATION
DIMENSIONS H W FD TF RF AC D1 D2
ASPECT 4 515mm 400mm 127mm 110mm 416mm 17.5mm 327mm 410mm
ASPECT 4 COMPACT
ASPECT 5 590mm
ASPECT 5 COMPACT
ASPECT 6 623mm 557mm 127mm 143mm 523mm 2 mm 343mm 422mm
ASPECT 7 550mm 579mm 127mm 110mm 451mm 17.5mm 327mm 410mm
ASPECT 8 623mm 617mm 127mm 128mm. 524mm 7mm 343mm 417mm
ASPECT 8 COMPACT
ASPECT 14 658mm 667mm 127mm
515mm 400mm 127mm 110mm 416mm 17.5mm 277mm 379mm
494mm 127mm 110mm
590mm 494mm 127mm 110mm 491mm 17.5mm 277mm 358mm
648mm 617mm 127mm 153mm
153mm 559mm NA
491mm 17.5mm 327mm 410mm
539mm 13mm 398mm
468mm 555mm
459mm
- 3 -
GENERAL INFORMATION
Meets the requirement of: European Standard EN-13240 DEFRA (Smoke Control Areas (UK)
Stove Model Nominal
Heat Output
Aspect 4 4.5kW 81.0% 56kg
Efciency Weight
Aspect 4 Compact
Aspect 5
Aspect 5 Compact
Aspect 6
Aspect 7 5.0kW 81.0% 86kg
Aspect 8 7.5kW 76.0% 110kg
Aspect 8 Compact
Aspect 14
!
The appliance will become very hot when used in accordance with the instructions. The supplied operating tool or glove may be used to open the door and operate the air controls. We also recommend use
of a reguard in the presence of childre, the elderley or the inrm. The reguard should be manufactured in
accordance with BS8423.
4.5kW 81.0%
5.0kW 80.0%
5.0kW 80.0%
5.0kW 80.0%
7.5kw 76.0%
7.8kW 77%
52kg
79kg
72kg
93kg
110kg
130kg
Competent Persons Scheme
Hunter Stoves Group recommend that this stove be installed by a member of an accredited competent persons scheme e.g. HETAS.
If the installer is not a member of a competent person’s scheme, it is a legal requirement, in the UK, to notify
your Local Building Control Ofcer in advance of any
installation work starting.
Legal Requirements
These instructions cover the basic principles to ensure satisfactory installation of the stove, although details
may need slight modication to suit particular local
site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws, European and National Standards and
other specications or regulations as they affect the
installation of the stove.
It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303, BS 6461 and BS 7566 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J.
Hearth
Hearth constructions must comply with the current building regulations.
Your stove must be installed on a oor with adequate
load-bearing capacity, otherwise suitable measures should be taken.
If the existing construction does not meet this pre-requisite, suitable measures (e.g. load distributing plate) should be put in place.
The hearth should extend at least 225mm from the front of the appliance(as per Building Regulations) we recommend 300 mm.
The stove should stand wholly above a solid, non-combustible hearth, at least 125 mm thick (this
may include the thickness of a solid oor).
Please refer to Building Regulations Approved Document J for further information.
- 4 -
Air Supply
Connection to the Chimney
Aspects 4, 4C, 5, 5C, 6 and 7
The room or space containing this appliance does not need a permanent, unobstructed air opening unless the air permeability rating is less than or equal to 5m³/ hour/m².
Aspects 8, 8 Compact, 14
The room or space containing this appliance does need a permanent, unobstructed air opening.
1375mm² - Aspect 8 1540mm² - Aspect 14.
All
If a draught stabiliser is tted, the air opening should
be at least: -
3825mm² (Aspect 4s), 4250mm² (Aspect 5s, 6 and 7) 3625mm² (Aspect 8) 3880mm² (Aspect 14).
Due consideration should be given to air requirements for any other appliance in the same room or space.
Any air opening must be kept clear from blockage or obstruction.
New Build
Attention is needed in new built properties where the design air permeability is less than 5m3/h.m2. Approved Document J and Appendix F gives further information. A window opening is not appropriate.
An existing replace opening can be bricked up or sealed with a register plate. A short length of ue pipe
of minimum 125mm internal diameter may then be
used to connect the stove to the chimney. This ue
pipe should be made of 316 grade stainless steel or vitreous enamelled steel, nominal thickness 1.2mm. Ensure that the pipe end is no closer than 76mm to the chimney walls. The length of any horizontal run of
ue pipe must not exceed 125mm. It is essential that all connections between the stove and chimney-ue
are sealed and made airtight. Any bend in the chimney
or connected ue pipe should not exceed 45
bends should not be used.
Ensure any existing chimneys are clear of obstruction and have been swept prior to installation. If the stove
is being tted into a previous open replace then the chimney must be swept one month after tting.
Make provision to access the chimney/ue system for
cleaning and the removal of debris. If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J, or a twin-walled insulated
stainless-steel ue to BS4543 can be used. These chimneys must be tted in accordance with the
manufacturer’s instructions and Building Regulations.
New masonry and ue block chimneys must meet
the requirements of Building Regulations Document
J. Any connecting ue pipe systems must also meet
these regulations.
Please check the suitability of the replace and/or
surround for use with this appliance before installing it. If you have any doubts about the suitability of your chimney, consult your local Dealer/Stockist or Installation Engineer.
0
and 90
0
Certicate of Compliance
After completionof the appliance instalation please ensure the form below (specimen) is completed by your installer to comply with the requirements of HETAS and building regulations. The installer must supply these details, including registration number for any insurance details that may need changing after installation of the appliance.
- 5 -
MATERIAL CLEARANCES
Hearth Requirements
Combustible/Non Combustible Distances
Model A (to Twin-
Walled
Flue)
Aspect 4 125mm 500mm 500mm
Aspect 4 Compact 125mm 500mm
Aspect 5 125mm 600mm 600mm 50mm 50mm 500mm 1230mm
Aspect 5 Compact 125mm 600mm 600mm 50mm 50mm 500mm 1230mm
Aspect 6 125mm 600mm 600mm 50mm 50mm 500mm 1230mm
Aspect 7 125mm 500mm 500mm 50mm 50mm 500mm 1230mm
Aspect 8 Compact 100mm 375mm 375mm 50mm 50mm 600mm 1200mm
Aspect 8 100mm 375mm 375mm 50mm 50mm 600mm 1200mm
Aspect 14 100mm 525mm 525mm 50mm 50mm 650mm 1500mm
For clearance distances for the single skin ue pipe please refer to Building Regulations Document J.
B
CombustibleCCombustible
500mm 50mm 50mm
B
Non
Combustible
50mm 50mm 500mm
C
Non
Combustible
Superimposed
Hearth
500mm 1230mm
D
Front
to
Furniture
1230mm
- 6 -