![](/html/c1/c1e4/c1e4eddc71532de0b6aa678bd4af2926fdf72d865072aff6ba9e0ab7c1e26489/bg1.png)
D O U B L E /
D O U B L E / D O U B L E
D O U B L E /D O U B L E /
H
H E R A L D
HH
E R A L D 1 4
E R A L D E R A L D
D O U B L E
D O U B L ED O U B L E
1 4
1 41 4
C E
C E
C EC E
M U L T I F U E L
M U L T I F U E L
M U L T I F U E L M U L T I F U E L
C L E A N B U R N
C L E A N B U R N
C L E A N B U R N C L E A N B U R N
S T O V E
S T O V E
S T O V ES T O V E
Installation and Operating Instructions
An accredited competent person must carry out the installation of this appliance;
alternatively, your local Building Control Officer can approve the completed
installation, should a non-accredited engineer undertake the installation. It is an
offence, under UK law, not to comply with this advice. Please hand these
instructions to the stove user when the installation is complete. Leave the system
ready for operation and instruct the user in the correct use of the appliance and
operation of controls.
![](/html/c1/c1e4/c1e4eddc71532de0b6aa678bd4af2926fdf72d865072aff6ba9e0ab7c1e26489/bg2.png)
Herald 14 Double-Double CE
Technical Specification
Wood
Total Efficiency 71.1 %
Nominal Heat Output 17.8 KW
Mean CO Emission (at 13% O2) 0.35 %
Mean Flue Gas Temperature 443 °C
Flue Gas Mass Flow 12.5 g/s
This appliance is not suitable for use in a shared flue
This appliance is suitable for intermittent burning
![](/html/c1/c1e4/c1e4eddc71532de0b6aa678bd4af2926fdf72d865072aff6ba9e0ab7c1e26489/bg3.png)
Assembly Instructions
PLEASE READ THESE INSTRUCTIONS CAREFULLY
It is important that your stove is correctly installed, as Hunter Stoves Limited cannot
accept responsibility for any fault arising through incorrect use or installation.
Important Warning
This stove must not be installed into a chimney that serves any other heating appliance.
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to
emit fumes into the room.
Flue Collar
Place the Flue Gasket on the Top Plate Flue Exit. Place the Flue Collar on top of the Gasket. Secure to
the four locating tabs, inside the flue outlet, using the M6 nuts & bolts supplied. Fit the 2 - M8 carriage
bolts, washers & nuts into the Damper Holes, located on each side of the Flue Collar.
![](/html/c1/c1e4/c1e4eddc71532de0b6aa678bd4af2926fdf72d865072aff6ba9e0ab7c1e26489/bg4.png)
Fire Bricks
The Fire Bricks, in this appliance, are factory fitted. The following set of photos show the removal sequence
that you will need to employ when servicing your Hunter Stove.
Side Bricks
Remove the outer 3 Riddling Bars (each side),
Slide out the Side Bricks from base, into the
Stove.
Baffle
Lift the Baffle and slide to the left.
When the right side of the Baffle clears
the Baffle Support, lower it into the Fire
Box and remove.
![](/html/c1/c1e4/c1e4eddc71532de0b6aa678bd4af2926fdf72d865072aff6ba9e0ab7c1e26489/bg5.png)
HETAS Ltd (Heating Equipment Testing and
Installation Instructions
These instructions cover the basic principles to ensure satisfactory installation of the stove,
although detail may need slight modification to suit particular local site conditions. In all cases
the installation must comply with current Building Regulations, Local Authority Byelaws and
other specifications or regulations as they affect the installation of the stove. It should be noted
that the Building Regulations requirements may be met by adopting the relevant
recommendations given in British Standards BS 8303, BS 6461 and BS 7566 as an alternative
means to achieve an equivalent level of performance to that obtained following the guidance given
in Approved Document J.
Competent Persons Scheme
Members of the following schemes may self-certify the installation of this stove. If the installer is not a
member of one of these schemes, your local building control department must approve the installation.
Scheme
APHC (Association of Plumbing and Heating
Contractors (Certification) Limited
Building Engineering Services Competence
Accreditation (BESCA Limited)
Web address
www.aphc.co.uk
www.hvca.org.uk /
www.besca.org.uk
Telephone
02476 470 626
0800 652 5533
Approval Scheme)
www.hetas.co.uk
NAPIT Registration Ltd www.napit.org.uk
NICEIC Group Ltd www.niceic.org.uk
01462 634721
0870 444 1392
0800 013 0900
Health and Safety Precautions
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In
case of contact, wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of
installation then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove, care should be taken to avoid the possibility of personal injury.