Must be able to
secure the fan to
building structure or
fan-rated outlet box
You may need a
friend to help you.
Check box to see
fan weight
If you are unfamiliar
with wiring, use a
qualied electrician.
Know your wiring
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
Assess ceiling angle
30 inches
from blade tip
to nearest wall
or obstruction
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
7 feet
from bottom
edge of blade
to the oor
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building
structure and/or an outlet box marked acceptable for
fan support of 70 lbs (31.8 kg) and use the mounting
screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing
or servicing your fan, disconnect the power by turning
off the circuit breakers to the outlet box and associated
wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent
warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor
damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the
blade brackets when installing the blade brackets, balancing
the blades, or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and
local electrical codes ANSI/NFPA 70. If you are unfamiliar
Connect the white
(grounded) wire from
the ceiling to the white
wire from the fan.
Connect the black wire
(ungrounded) from the
ceiling to the black and the
blue wires from the fan.
White
Blue
Black
Grounded
Ungrounded
Grounded
G
r
e
e
n
/
Y
e
l
l
o
w
Grounding
Green/Yellow Stripe
S
Dual Switch
Instructions
t
r
i
p
e
Connect the three
grounding wires (green,
green/yellow stripe, or
bare copper) coming from
the ceiling, downrod, and
hanging bracket.
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then
twist clockwise until tight.
Refer to CAUTION c.1 on pg. 2
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Connect the white
(grounded) wire from
the ceiling to the white
wire from the fan.
Connect the black wire
(ungrounded) from the
ceiling to the black
wire from the fan.
White
Ungrounded
Black
Grounded
Ungrounded (light)
Grounded
G
r
e
e
n
/
Y
e
l
l
o
w
Grounding
Green/Yellow Stripe
S
www.HunterFan.com
t
r
i
p
e
1.888.830.1326
Connect the three
grounding wires (green,
green/yellow stripe, or
bare copper) coming from
the ceiling, downrod, and
hanging bracket.
Refer to CAUTION c.1 on pg. 2
Connect the second
ungrounded (light)
wire from the
celing to the blue
wire from the fan.
Blue
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then
twist clockwise until tight.
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch