Must be able to
secure the fan to
building structure or
fan-rated outlet box
You may need a
friend to help you.
Check box to see
fan weight
If you are unfamiliar
with wiring, use a
qualied electrician.
Know your wiring
30 inches
from blade tip
to nearest wall
or obstruction
Assess location
7 feet
from bottom
edge of blade
to the oor
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building
structure and/or an outlet box marked acceptable for
fan support of 70 lbs (31.8 kg) and use the mounting
screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing
or servicing your fan, disconnect the power by turning
off the circuit breakers to the outlet box and associated
wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent
warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor
damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the
blade brackets when installing the blade brackets, balancing
the blades, or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and
local electrical codes ANSI/NFPA 70. If you are unfamiliar
hold the bare metal leads
together and place a wire
E
C
I
L
M
I
O
R
F
N
G
connector over them, then twist
clockwise until tight.
M
O
R
F
Refer to CAUTION c.1 on pg. 2
Green/Yellow Stripe
(grounding)
F
A
N
Black (ungrounded)
White (grounded)White
Using the orange
Green/Yellow Stripe
F
R
O
M
C
E
I
L
Green/Yellow Stripe
I
N
connector from
thehardware bag,
Blue
Black
wires (green, green/
yellow stripe, or bare
copper) coming from
the ceiling, fan, and
hanging bracket.
T
E
K
C
A
R
B
G
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
F
R
O
M
N
A
F
wire connectors from
thehardware bag,
connect the black wire
(ungrounded) from the
ceiling to the black and
the blue wires from the
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch