Hunter Fan NiteGlo Evaporative Humidifier User Manual [en, es, fr]

The Care Free®
Humidifi er Plus
Evaporative Humidifi er
ENGLISH
See page 2
Vea la página 13
ESPAÑOL
Consulter la page 25
FRANÇAIS
Features (Vary By Model):
NiteGlo™ Night Light
Digital Humidistat
Automatic Shut-Off
www.hunterfan.com
41713-01 07/19/2004 1 ©2004 HUNTER FAN CO.
41713_booklet.indd 1 7/19/04, 7:22:34 PM
READ AND SAVE THESE INSTRUCTIONS
Important Safety Instructions:
Read all instructions before
using this humidifi er.
1. This humidifier may not work prop-
erly on an uneven surface. ALWAYS place this humidifi er on a fi rm, level, and water resistant surface. ALWAYS place the humidifi er at least six (6) inches away from walls and heat sources such as stoves, radiators, or heaters.
2. ALWAYS place the humidifier in an
area that is out of the reach of children.
3. Before using the humidifier, extend the cord and inspect for any signs of damage. DO NOT use the product if the cord has been damaged.
4. This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fi t into a polarized outlet only one way. If the plug does not fi t fully into the outlet, reverse the plug. If it still does not fi t, contact a qualifi ed electrician. DO NOT attempt to defeat or override this safety feature.
5. ALWAYS UNPLUG AND EMPTY
the humidifi er when it is not in opera­tion or while it is being cleaned.
6. DO NOT tilt or move the humidifi er
while it is in operation. Never move the humidifi er while there is water in the tank. Empty the water tank, turn off, and unplug the unit before moving.
7. In addition to routine maintenance which may be required, this humidifi er requires seasonal cleaning. Refer to and follow CLEANING THE HUMIDIFIER AND THE WATER TANK instructions.
8. This unit is designed to be used with distilled and/or tap water. DO NOT add scented oils, perfumes, or fragrance ad­ditives to the water.
Thank you for purchasing The Care Free
Humidifi er Plus Evaporative Humidifi er by Hunter Fan Company. Please read and save these instructions to receive the maximum benefi t and performance from your humidifi er.
®
How the Care Free® Humidifi er Plus
Evaporative Humidifi er Works
The Care Free® Humidifier Plus Evaporative Humidifi er has a unique patented design with several innovative features:
• Low Maintenance – Other humidifi ers have
paper fi lters that need to be replaced every few months. Our exclusive PermaWick™ fi lter saves time and money. It’s designed to last season after season, saving up to $45 a year. No wet paper odors either.
• Pump System – By dispersing water from
the top of the PermaWick™ fi lter, stagnant water around the PermaWick™ filter is eliminated, and the buildup of mineral
41713-01 07/19/2004 2 ©2004 HUNTER FAN CO.
41713_booklet.indd 2 7/19/04, 7:22:35 PM
residue that can clog the fi lter and impede performance is eliminated.
NOTE: The fi lter has a coating on the wick
which may make it appear old or used, but is actually new.
• Built-in Antimicrobial Properties – The
plastic parts and the PermaWick™ fi lter have built-in antimicrobial properties to inhibit the growth of bacteria, mold and fungi that may affect these parts.
NOTE: This product contains antimicrobial
properties which are built-in to inhibit the growth of bacteria which may affect the
plastic and PermaWick™ fi lter in the hu­midifi er. These properties do not extend to the water, humidifi ed air or users. Conduct routine cleaning and maintenance based upon use and individual conditions.
• No White Dust – The Care Free
®
fi er Plus Evaporative Humidifi er produces no white dust that can settle on furniture or be inhaled.
Humidi-
NOTE: You may notice mineral deposits
accumulating in the tank base or on the PermaWick™ fi lter. This is normal and does not affect performance. If you would like to clean these deposits away, please see CLEANING THE HUMIDIFIER AND WATER TANK.
Filter Frame Hooks
Lift Up
Push
Humidifi er Parts
Water Tank
Humidistat Display and Controls
Easy Tote Handle
Power/ Speed Control
Main Housing
ENGLISH
Tan k Cap
Water Diffuser Cap
PermaWick™ Filter
PermaWick™ Filter Frame
Insert Guides Into Base
Base
Figure 1
41713-01 07/19/2004 3 ©2004 HUNTER FAN CO.
41713_booklet.indd 3 7/19/04, 7:22:36 PM
Humidifi er Features
For Model 33255
Power/Speed Control: Tu rns the humidifi er ‘ON’ and ‘OFF’. The power should always be off before unplugging the humidifi er, moving the humidifi er, or refi lling the water tank.
Power Light: The red light will be illuminated when the power is on and the humidistat light is on.
Humidistat Display and Controls: Enables you to set desired maximum humidity level. Once this level is exceeded, the unit will shut off until the humidity level drops.
NOTE: The humidifi er may not be running be­cause the humidistat setting may need to be adjusted.
Humidistat Light: The green light will go off when the humidity in the room exceeds the level that you selected with the digital humidistat.
For Model 33257
Power/Speed Control: Tu rns the humidifi er ‘ON’ and ‘OFF’. The power should always be off before unplugging the humidifi er, moving the humidifi er, or refi lling the water tank.
Power Light: The red light will be illuminated when the power is on and the humidistat light is on.
Humidistat Display and Controls: Enables you to set desired maximum humidity level. Once this level is exceeded, the unit will shut off until the humidity level drops.
NOTE: The humidifi er may not be running be­cause the humidistat setting may need to be adjusted.
Humidistat Light: The green light will go off when the humidity in the room exceeds the level that you selected with the digital humidistat. Ni­teGlo™ Night Light Control: Turns the night light ‘ON’ and ‘OFF’. The night light can be turned on even if the humidifi er fan is turned off.
Humidistat Light
Humidistat Display and Controls
Humidistat Light
Humidistat Display and Controls
Power Light
Power/ Speed Control
Figure 2
Power Light
Power/ Speed Control
NiteGlo™ Night Light Control
Figure 3
41713-01 07/19/2004 4 ©2004 HUNTER FAN CO.
41713_booklet.indd 4 7/19/04, 7:22:36 PM
For Models 34355 & 34356
Power/Speed Control: Tu rns the humidifi er ‘ON’ and ‘OFF’. The power should always be off before unplugging the humidifi er, moving the humidifi er, or refi lling the water tank.
Refi ll Light: The red light will be illuminated to signal you that the humidifi er has automati­cally turned off and the water tank needs to be refi lled.
Humidistat Display and Controls: Enables you to set desired maximum humidity level. Once this level is exceeded, the unit will shut off until the humidity level drops.
NOTE: The humidifi er may not be running because the humidistat setting may need to be adjusted.
Humidistat Light: The green light will go off when the humidity in the room exceeds the level that you selected with the digital humidistat.
For Model 34357
Power/Speed Control: Tu rns the humidifi er ‘ON’ and ‘OFF’. The power should always be off before unplugging the humidifi er, moving the humidifi er, or refi lling the water tank.
Refi ll Light: The red light will be illuminated to signal you that the humidifi er has automati­cally turned off and the water tank needs to be refi lled.
Humidistat Display and Controls: Enables you to set desired maximum humidity level. Once this level is exceeded, the unit will shut off until the humidity level drops.
NOTE: The humidifi er may not be running because the humidistat setting may need to be adjusted.
Humidistat Light: The green light will go off when the humidity in the room exceeds the level that you selected with the digital humidistat.
Humidistat Light
Humidistat Display and Controls
Refi ll Light
Power/ Speed Control
Figure 4
Humidistat Light
Humidistat Display and Controls
Refi ll Light
Power/ Speed Control
NiteGlo™ Night Light Control
Figure 5
NiteGlo™ Night Light Control: Tu rns the night light ‘ON’ and ‘OFF’. The night light can be turned on even if the humidifi er fan is turned off.
ENGLISH
41713-01 07/19/2004 5 ©2004 HUNTER FAN CO.
41713_booklet.indd 5 7/19/04, 7:22:37 PM
Using Your Humidifi er
1. Remove The Care Free® Humidifier Plus Evaporative Humidifi er from its packaging. Read and Save the Instructions.
2. Place the humidifier on a hard, flat, water resistant surface. Always place the humidifi er at least six (6) inches away from walls and sources of heat.
3. Lift the main housing to confirm that the PermaWick™ fi lters are placed upright in the slots. Replace the main housing. (See Figure 1.)
4. Remove the water tank and take it to the sink or tub to fi ll.
5. Turn the tank upside down and unscrew the tank cap by turning it coun­terclockwise. Fill the water tank with cool water and replace the tank cap (Never use hot water). Be sure not to overfi ll the tank as water damage may occur to furniture or fl ooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBILITY
FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE.
6. Carry the tank back to the humidifier. Turn the tank upright and place it on the humidifi er. Be sure that the tank is seated properly in the base. If the tank is properly located on the base, you will see air bubbles fl owing up into the tank.
8. Place the full tank on the unit and allow the water to fi ll the bottom tray. The water is at the proper level in the bottom tray when the tank stops bubbling. Run the unit on
“HI” speed for 1
1
2 minutes for optimum
pump operation. Set the unit to the desired
speed.
9. Use the power/speed control knob to turn the humidifi er ‘ON’ by selecting a speed setting.
Only for models with Automatic Shut-off
10. When the water tank is empty, the humidi­fi er will automatically shut itself off. The red light will be illuminated, indicating that the water tank needs to be refi lled.
11. Follow REFILLING THE WATER TANK direc­tions. Once the water tank is refi lled, the Refi ll Light will not be illuminated.
Only for models with a NiteGlo™ Night Light
12. Use the control to turn the night light off and on. The night light can be operated even if the humidifi er fan is turned ‘OFF’.
7. With the power control knob in the ‘OFF’ position, plug the humidifi er into the wall.
CAUTION: Never plug in the Humidifi er
while your hands are wet as Electric Shock could occur.
41713-01 07/19/2004 6 ©2004 HUNTER FAN CO.
41713_booklet.indd 6 7/19/04, 7:22:37 PM
Using Your Digital Humidistat
Setting the Desired Humidity
NOTE: After unplugging the humidifi er to
move the humidifi er, to refi ll the water tank or to clean the humidifi er, you must reset the digital humidistat.
Refer to Figure 6.
1. Use the power/speed control knob to turn the humidifi er ‘ON’ by selecting a speed setting.
NOTE: A speed setting must be chosen
before the humidistat will operate the humidifi er.
2. In normal mode use the humidistat control buttons to set the desired humidity level. The settings range from 30% to 80% in 5% increments.
3. When the humidity exceeds the level you have set, the humidistat light will go off. The humidifi er will not output humidity while the humidity in the room is at the se­lected humidity level. The humidistat light will stay off until the humidity changes. When the humidity in the room drops be­low the selected level, the humidifi er will cycle on again and the humidistat light will come on.
Setting the Span
Refer to Figure 7. Your humidistat is set at the factory to cycle at
setting 2. If you fi nd your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time.
4. Press and hold both humidistat con­trol buttons for two seconds to enter span setting mode.
5. In span mode, use the humidistat control buttons to adjust the span. Raise the span to 3 to increase the cycle time and allow your system to run longer. Lower the span to 1 to decrease the cycle time and allow your system to run shorter.
6. The humidistat display will return to normal mode after keys are idle for 5 seconds.
ENGLISH
Humidistat Light
Humidistat Control Buttons
Figure 7
Humidistat Control Buttons
Figure 6
41713-01 07/19/2004 7 ©2004 HUNTER FAN CO.
41713_booklet.indd 7 7/19/04, 7:22:38 PM
Refi lling the Water Tank
1. When the water tank level is low, turn the humidifi er ‘OFF’, and unplug.
2. Remove the tank and take it to the sink or tub to refi ll.
3. Turn the tank upside down and un­screw the tank cap by turning it counter­clockwise. Empty the tank, refi ll with fresh cool water (never use hot water), and replace the tank cap. Be sure not to overfi ll the tank as water damage may occur to furniture or fl ooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBILITY
FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE.
4. Carry the tank back to the humidifier. Turn the tank upright and place it on the humidifi er. Be sure that the tank is seated properly in the base. If the tank is properly located on the base, you will see air bubbles fl owing up into the tank.
5. Place the full tank on the unit and allow the water to fi ll the bottom tray. The water is at the proper level in the bottom tray when the tank stops bubbling. Run the unit on
“HI” speed for 1 pump operation. Set the unit to the desired
speed.
1
Cleaning the Humidifi er and the Water Tank
Many regions have hard water with high con­centrations of minerals. When water evaporates from The Care Free Humidifi er, minerals may be left behind. These minerals can form a hard white scale which can be removed by following the cleaning instruc­tions. The frequency of cleaning due to mineral build up can vary depending upon the quality of water you may have.
Refer to Figure 1 for part names.
1. Turn the humidifier ‘OFF’ and unplug the unit.
2. Lift the main housing and remove the water dispersion tray and the PermaWick™ Filters. The motor is attached to the main
housing. Do not place the motor near water. Do not use a wet towel on the motor or motor housing as electrical shock may occur.
3. The PermaWick™ Filter should be cleaned in a vinegar and water solution to remove any mineral buildup. Place in a solu­tion of one (1) gallon of water and eight (8) ounces of undiluted white vinegar. Allow the fi lter to soak for 20 minutes.
®
Humidifi er Plus Evaporative
4. After soaking, rinse it several times with clean water. Place the PermaWick™ Filter in a location where it can drip dry while you clean the other parts of your humidifi er.
5. Remove the water tank from the base and empty any water that is left in the tank. Soak the base in a mixture of one (1) gallon of water and eight (8) ounces of vinegar for 20 minutes.
6. After soaking, wipe the base with a soft cloth or sponge to remove any mineral build up. Rinse with clean water several times. If you are planning on storing the humidifi er, be sure the base is completely dry.
7. Fill the water tank with one (1) gal­lon of water and eight ounces of undiluted white vinegar. Replace the tank cap and shake the tank vigorously until all interior surfaces of the tank have been exposed to the water/vinegar mixture.
8. Empty the tank of the water/vinegar mixture. Rinse it several times with clean water and then replace the tank cap. If you are planning on storing the humidifi er, dry it inside and out, leaving the cap off to allow
2 minutes for optimum
41713-01 07/19/2004 8 ©2004 HUNTER FAN CO.
41713_booklet.indd 8 7/19/04, 7:22:38 PM
the tank to completely dry. Continue to clean the other parts of your humidifi er.
9. Remove the water diffuser cap by squeezing the two tabs as shown in Figure
8. Rinse the cap in clean water to remove any debris. If the cap contains hard water residue, soak it in a mixture of one (1) quart of water and two (2) ounces of vinegar for 20 minutes. Rinse well and reinstall the water diffuser cap. Do not expose mo-
tor or other electrical components to water.
Water Diffuser Cap
Figure 8
10. Wipe the surfaces of the main housing with a soft cloth.
11. Once all the parts are clean, reassemble the humidifi er, and follow the USING YOUR
HUMIDIFIER instructions to continue use. If you are storing the humidifi er, make sure the parts are completely dry, reas­semble, and store in a dry location.
ENGLISH
Tab
Tab
Service Parts
To obtain a service part for your humidifi er, call customer service at 1-888-830-1326 or e-mail us at Techsupport@hunterfanhq.com. Please be prepared to tell the operator the model number of your humidifi er and the name of the part you need to replace and the part number. Refer to Figure 1 for part names.
Model
41713-01 07/19/2004 9 ©2004 HUNTER FAN CO.
41713_booklet.indd 9 7/19/04, 7:22:39 PM
Filter Frame Base Water Tank
No.
33255
95449-01-000 95402-01-325 95160-01-326
33257 34355
95451-01-000
34357 95401-01-325 95182-01-326 65115-01-325 86113-01-325
95401-01-325 95182-01-326
Power/Speed
Control
65115-01-325 86113-01-325
Tank Cap
Water
Diffuser Cap
74884-01-000
PermaWick
Filter
74080
7408234356 95401-01-361 95182-01-363 65115-01-362 86113-01-362
Hunter Fan Company
The Care Free
®
Hu mid i fi er Plus
Evaporative Humidifi er
5 YEAR LIMITED WARRANTY
The Hunter Fan Company, Inc. makes the follow­ing warranty to the original residential user or consumer purchaser of The Care Free fi er Plus Evaporative Humidifi er:
If any part of The Care Free Evaporative Humidifi er (“Humidifi er”) motor fails during the fi rst 5 (fi ve) years from the date of installation due to a defect in material or workmanship, we will provide a replacement part free of charge. If no replacement part can be provided for such motor, we will replace your humidifi er.
If your Humidifi er motor fails any time within 1 (one) year after the date of installation due to a defect in material or workmanship, labor to repair the defect will be provided free of charge at our nearest service centre or at our Service Department in Memphis, Tennessee. You will be responsible for all parts and labor costs after this one-year period.
If your Humidifi er water tank, fi lter frame, base, knobs, or tank cap fail any time within 1 (one) year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the water tank, fi lter frame, base, knobs, or tank cap free of charge for parts or labor performed at our nearest service centre or our Service Department in Memphis, Tennessee.
IF THE ORIGINAL RESIDENTIAL USER OR CON­SUMER PURCHASER CEASES TO OWN THE HU­MIDIFIER, THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED.
NO WARRANTY, EXPRESSED OR IMPLIED, IN­CLUDING ANY WARRANTY OF MERCHANTABIL-
®
Humidi-
®
Humidifi er Plus
ITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT TO THE FILTER.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PAR­TICULAR PURPOSE, IN RESPECT TO THE MOTOR IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE.
This warranty is voided if your Humidifi er is not purchased and used in the USA or Canada.
This warranty excludes and does not cover de­fects, malfunctions, or failures of the Humidifi er which were caused by repairs by persons not authorized by us, use of parts, or accessories not authorized by us, mishandling, modifi cations, or damage to the Humidifi er while in your posses­sion, or unreasonable use, including failure to provide reasonable and necessary maintenance. This warranty does not cover humidifi ers used in commercial applications. There are no express or implied warranties as to commercial purchasers or users.
To obtain service, contact the nearest Hunter au­thorized service centre or the Hunter Fan Com­pany Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114, 901-248-2222. You will be responsible for insurance and freight or other transportation to our factory service center. We will return the Humidifi er freight prepaid to you. The Humidifi er should be properly pack­aged to avoid damage in transit since we will not be responsible for any such damage. Proof of purchase is required when requesting war­ranty service. The purchaser must present the sales receipt or other document that establishes proof of purchase.
41713-01 07/19/2004 10 ©2004 HUNTER FAN CO.
41713_booklet.indd 10 7/19/04, 7:22:39 PM
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE HUMIDIFIER. YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE.
SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW
• LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS;
• THE EXCLUSION OR LIMITATION OF DI­RECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES;
• THE EXCLUSION OR INVALIDITY OF EX­PRESS OR IMPLIED WARRANTIES IF THE USER CEASES TO OWN THE HUMIDI­FIER;
• THE LIMITATION OF THE REMEDIES AND RECOURSES AVAILABLE TO THE PUR­CHASER; OR
• THE INVALIDITY OF AN EXPRESS WAR­RANTY WHEN A PRODUCT IDENTIFIED BY BRAND NAME IS NOT USED (UNLESS SPECIFIC CONDITIONS ARE FULFILLED);
SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE.
ENGLISH
41713-01 07/19/2004 11 ©2004 HUNTER FAN CO.
41713_booklet.indd 11 7/19/04, 7:22:40 PM
Loading...
+ 25 hidden pages