READ AND SAVE THESE INSTRUCTIONS
before beginning installation
1
43533-01 05/28/2008
43533-01 05/28/2008
2
43533-01 05/28/2008
3
43533-01 05/28/2008
READ AND SAVE THESE INSTRUCTIONS
!
WARNING
TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE
FOLLOWING:
• Be cautious! Read all instructions and safety information before installing your new Illumi-heat semi-flush fixture. Carefully review the assembly illustrations.
• Use this unit only in the manner intended.
All wiring must be in accordance with national and local electrical codes. If you are unfamil-
iar with wiring, you should use a qualified electrician.
• Before you begin installing the fixture, switch power off at the correct breaker, turn on the
bulb switch to make sure breaker handle was sitting on the right position, and lock the breaker
box to prevent power from being switched on accidentally during installation. When the breaker box cannot be locked, securely fasten a prominent warning device such as a danger tag to the breaker box.
• To reduce the risk of fire, electric shock, or personal injury this fixture must be mounted as marked.
• Only use this fixture with the transmitter supplied by Hunter.
• Mounting structure must be capable of supporting this product weight of 9.0 lbs.
Transmitter and
Transmitter Holder
(not to scale)
PARTS
Verify all parts were in the box before installing.
Hanger Bracket
Heater/Light Fixture
Wires: Black, White, Copper (Ground)
Acorn Nuts (2)
Receiver
Light Sockets (3)
Turn off the power source.
BEFORE BEGINNING, DISCONNECT THE POWER SUPPLY AT THE BREAKER BOX. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH
Wire Connectors (3)
(not to scale)
Flat head screwdriver
Tools Needed (not supplied)
Phillips screwdriver
Glass Dome
Finial
Needle-nosed Pliers
4
43533-01 05/28/2008
5
43533-01 05/28/2008
P R E - I N S TA L L ATION f o r M u l i t p l e I l l u m i - H e a t
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
Units in Your Home
P R E - I N S TA L L AT I O N f o r M u l i t p l e I l l u m i - H e a t
Units in Your Home
If you are going to install more than one Illumi-Heat in your home, then you will need to assign each unit a its own unique Transmitter / Receiver Code.
1) Looking at the fixture from its top, locate the Receiver, as shown in Figure 1.
Top View of Fixture
(Bracket cut away
for clarity.)
Receiver
3) Configure the Receiver Switches to your desired code. Make a note of which Receiver Switches you turned On and turned Off. NOTE: Make certain each Receiver is assigned a
different code.
4) Remove the Transmitter Battery Compartment door as shown in Figure 3.
Transmitter Battery
Compartment Door
Figure 1 - Receiver
2) On the Receiver you will see the four switches that you will use to set the code for the Transmitter and the Receiver. See Figure 2.
Switches
NOTE - All Switches are
shown in the ON position
Figure 2 - Receiver Code Switches
Figure 3 - Remove Transmitter Battery Compartment Door
5) For every Receiver Code Switch you turned Off, use a pair of needle-nosed pliers to carefully remove its corresponding Connector from the Transmitter Terminals. See Figure 4. For instance, if you turned Off Receiver Switches 1 and 3, then you would remove Connectors 1 and 3 from the Transmitter.
Transmitter Terminals
1234
Connector
Figure 4 - Transmitter Terminals and Connector
43533-01 05/28/2008
6
43533-01 05/28/2008
7
INSTALLATION
INSTALLATION continued
1) If you are replacing an existing light fixture, disconnect and remove the old fixture and hanger bracket, leaving the exposed wires coming from the electrical box.
2) Attach the Hanger Bracket assembly to the electrical box as shown in Figure 5.
Electrical Box
Hanger Bracket
3) Suspend the fixture by placing the Cable Loop over the Cable Loop Hanger. See Figure 6.
Cable Loop Hanger
Cable Loop
Figure 5 - Attach Hanger to Electrical Box
Figure 6 - Suspend the Fixture
4) Use UL-approved wire connectors to connect the wires, black-to-black, white-to-white. Loop the ground wires around the Ground Screw, then tighten the Ground Screw. See Figure 7.
Ground Screw
Figure 7 - Ground Screw