Hunter Fan HTF3585 Owner Manual

Page 1
30 inches
7 feet
Ladder
Table of Contents
www.HunterFan.com
1.888.830.1326
Congratulations on purchasing your new Hunter® ceiling fan! It will provide comfort and performance
in your home or ofce for many
years. This installation and operation manual contains complete instructions for installing and operating your fan.
We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
Switch Housing Light Kit
What to Expect with
2
6
Tools Needed
PAG E
PAG E
Remote Control
Mounting Options
PAG E
3
Wiring CanopyDownrod
PAG E
9
Operation,
Maintenance & Cleaning
4
11
Ceiling Bracket
PAG E
Blades
PAG E
Troubleshooting
PAG E
5
PAG E
12
?
?
13
PAG E
14
PAG E
PAG E
16
17
PAG E
?
PAG E
19
1
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Page 2
What to Expect with Your Installation
If you are unfamiliar with wiring, use a
qualied electrician.
Must be able to secure the fan to building structure or fan-rated outlet box
You may need a friend to help you.
Check box to see fan weight
Know your wiring
Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.
Assess ceiling angle
30 inches
from blade tip to nearest wall or obstruction
7 feet
from bottom
edge of blade
to the oor
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
2
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or personal injury,
mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when
installing the blade brackets, balancing the blades, or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and local electrical codes
ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: modications not approved by the party responsible for compliance
could void user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 3
Tools Needed
www.HunterFan.com
1.888.830.1326
Ladder
Pliers Wire Strippers
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
9/64” Drill Bit
(optional)
3
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Screwdrivers
Page 4
O
34
CEILING
Mounting Options
www.HunterFan.com
1.888.830.1326
OPTION
If you have a at ceiling:
WALL
Hang your fan by a standard downrod (included).
Standard Mounting
1
Support Structure
Support Structure
OPTION
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
Use the three steps below to determine if your ceiling angle is greater than 34°
Angled Mounting
2
Standard Mounting Style
Ceiling
Outlet Box
(required)
Angled Mounting Style
Ceiling
Outlet Box
(required)
FOLD
on dotted line
1
N
O
I
T
A
U
T
I
S
1
34°
Guide Touches
BOTH Ceiling & Wall
You need ONLY
a Longer
Downrod
*most common
2 3
PLACE
against wall
2
N
O
I
T
A
U
T
I
S
Guide Touches
but NOT Ceiling
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
SLIDE
toward ceiling
Wall
to hang the fan from a at ceiling.
4
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Use Standard Mounting
or Low-Prole Mounting
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
Page 5
Ceiling Bracket
Turn Power
OFF
For angled ceilings, point
opening toward peak.
www.HunterFan.com
1.888.830.1326
Make sure all four bumpers are
still attached.
Refer to warning w.1 on pg. 2
If you are unable to do this,
call Technical Support at
1-888-830-1326.
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Use wood screws (included) when securing to support structure with approved electrical outlet
box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket
with hardware found in
the hardware bag.
5
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet
box associated with the wall switch location.
Page 6
Downrod
www.HunterFan.com
1.888.830.1326
Standard Downrod
for ceilings 8-10’ high
Option 1Option 2
Shorter Downrod
for fans installed close to ceiling
Included
(pre-assembled)
Longer Downrod
for angled ceilings or
Option 3
ceilings 10’ or higher
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
1 2 3 4 5
Slide
Slide
678910
Included
Sold Separately
Steps 6-10 to reassemble with new pipe
6
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Page 7
Downrod (continued)
www.HunterFan.com
1.888.830.1326
KEEP!
E
E
P
K
!
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
8”
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
3/8”
T
U
C
P
I
R
T
S
&
8”
(not to scale)
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
3/8”
If the setscrew is not tightened securely, the fan may fall.
7
Page 8
Downrod (continued)
DO NOT PICK THE FAN UP BY THE
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
www.HunterFan.com
1.888.830.1326
of the fan.
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
8
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Page 9
Wiring
Receiver
Note: To connect the wires, hold the bare metal leads together and place a wire connector over them,
then twist clockwise until tight.
www.HunterFan.com
E
C
I
L
M
I
O
R
F
N
G
1.888.830.1326
Place the receiver on top of the
downrod assembly as shown.
Refer to CAUTION c.1 on pg. 2
Using an orange wire connector from the hardware bag:
Connect the 3 grounding wires (green, green/yellow stripe, or bare copper) coming from the ceiling, downrod, and ceiling bracket.
Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
9
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
green/yellow
stripe (grounding)
F
A
M
N
O
R
F
green/yellow stripe
green/yellow
stripe
F
R
O
M
C
E
I
L
I
G
N
T
E
K
C
A
R
B
Page 10
Wiring (continued)
www.HunterFan.com
E
C
R
E
I
M
O
R
F
V
E
R
E
C
I
L
M
I
O
R
F
N
G
1.888.830.1326
Using the orange wire connectors from the remote control hardware bag:
Connect the yellow wire from the receiver to the black wire from the fan.
Connect the blue wire from the receiver to the blue wire (or possibly black with white stripe wire) from the fan.
Refer to CAUTION c.1 on pg. 2
yellow
black
F
blue
Using the orange wire connectors
black
(ungrounded)
white (grounded)
from the hardware bag:
F
A
M
N
Connect the black (ungrounded)
O
R
F
wire from the ceiling to the black wire from the receiver.
white
white
blue
Connect the white (grounded) wire from the ceiling to both the white wire from the receiver and
black
the white wire from the fan.
F
R
R
N
O
A
F
M
Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
O
M
R
R
E
V
I
E
C
E
10
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Page 11
Canopy
Screw Holes
www.HunterFan.com
1.888.830.1326
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Lift the canopy into place so that
the screw holes are aligned.
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Insert the two canopy screws
found in the hardware bag.
Note: Fan style may vary.
11
Page 12
Blades
www.HunterFan.com
1.888.830.1326
Attach each blade to a blade iron using three
blade washers, found in the hardware
bag, and three blade assembly screws, found
in the hardware bag.
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
12
Page 13
Switch Housing
www.HunterFan.com
1.888.830.1326
Screw two housing assembly screws from
the hardware bag halfway into the
motor housing. It does not matter which
two screw holes you choose.
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
13
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Insert the third screw, found in the
hardware bag, into place and then tighten
all three screws.
Make sure the upper switch housing is securely attached to the mounting plate. Failure to properly secure all 3 assembly screws could result in the switch
housing xture falling.
Page 14
Light Kit
www.HunterFan.com
1.888.830.1326
Screw two housing assembly screws from
the hardware bag halfway into the
upper switch housing. It does not matter
which two screw holes you choose.
Connect the plugs from the upper
and lower switch housings. Make sure
to line up the colored markings on
the connectors.Wrap light kit keyhole
slots around the screws and twist
counterclockwise.
14
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Install the third switch housing screw.
Tighten all three screws securely.
Make sure the lower switch housing is securely attached to the upper switch housing. Failure to properly secure all three
assembly screws could result in the light xture falling.
Page 15
Light Kit (continued)
Tab
Notch
www.HunterFan.com
1.888.830.1326
Install a bulb into each of the sockets.
When necessary, replace with bulbs of the
same type and wattage.
Lift the globe and align the notches in the
globe with the tabs in the light kit. Attach
the glass bowl to the light kit by twisting it
clockwise until it snaps into place.
15
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Page 16
Remote Control
www.HunterFan.com
1.888.830.1326
Battery Door
Phillips Head Screw
To access the battery compartment, remove the small Phillips head screw that secures the battery door to the transmitter assembly. The
battery should be installed with the positive
(+) side up. Replace with a CR2032 battery
when necessary.
Switch Cover Plate
Removed Tabs
To install the transmitter cradle, remove the
two screws holding the switch cover plate. Do
not remove the cover plate. Orient the cradle
by lining up the two mounting holes with
those on the cover plate. Insert and tighten
the screws. Do not over tighten.
Note: For rocker-style cover plates, break off
the tabs by pushing outward.
Rocker- Style
Plate
16
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Turn Power
ON
CONGRATULATIONS!
YOU’RE DONE!
See next page for fan operation instructions.
Page 17
Operation, Maintenance, & Cleaning
Medium
Speed
Fan Off
High
Speed
www.HunterFan.com
1.888.830.1326
Low
Light
Speed
To turn on fan, press a fan speed button.
Speeds range from off (0) to high (3). Quickly
press the Light button to turn the lights off
and on. Hold the Light button to raise and
dim the light level.
The remote transmitter should already be paired
to the receiver and ready to use.
Note: If your need to pair your remote, turn fan
power off and back on at the wall switch. Within 3
minutes, press and hold both the Fan Off button
and the High button for 4 seconds to pair the remote. To prevent faulty operation, please
ensure all other ceiling fans within range are
turned off at the wall switch while pairing.
17
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Reverse Switch
To switch the direction of air ow, move the
reverse switch to the opposite position. You
will need to remove the glass to do so.
Page 18
Operation, Maintenance, & Cleaning (continued)
www.HunterFan.com
1.888.830.1326
Safe-Exit
The Safe-Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the lights go out. To use Safe-Exit:
• Press the Fan Off button for at least three seconds to initiate the Safe-Exit Mode.
The lights will ash for visual
conrmation.
• The lights will stay on 50% brightness for 15 seconds and then begin to dim. After a total of 30 seconds, the lights will be completely off.
Changing the bulbs - carefully
remove the globe. Unscrew bulbs
and replace with bulbs of the same
wattage. Reinstall the globe.
When cleaning the fan, use soft brushes
or cloths to prevent scratching. Cleaning
products may damage the nishes.
18
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Page 19
Troubleshooting
www.HunterFan.com
1.888.830.1326
Fan doesn’t work
• Make sure power switch is on.
• Pull the pull chain to make sure it is on.
• Push the motor reversing switch
rmly left or right to ensure that
it is engaged.
• Check the circuit breaker to ensure the power is turned on.
• Make sure the blades spin freely.
• Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram on pages 9-10.
• Check the plug connection in the switch housing.
Excessive wobbling
• Tighten all of the blade and blade iron screws until they are snug.
• Turn the power off, support the fan carefully, and check that the hanger ball is properly seated.
• Use the provided balancing kit and instructions to balance the fan.
Remote control of fan is erratic
• Make sure the battery is installed correctly.
• Install a fresh battery.
Transmitter only works when held at close range
• Change battery.
Noisy operation
• Tighten the blade and blade iron screws until they are snug.
• Check to see if any of the blades are cracked. If so, replace all of the blades.
If you have multiple remotes or multiple remote-controlled fans installed on the same circuit breaker and you are experiencing
interference or faulty operation of your remote controls, please go to www.HunterFan.com/FAQs and click “How do I properly install multiple remote-controlled fans?” for information on how to correct this issue.
Lights dim when turned on or do not turn on at all.
• Make sure the wattage of the light bulbs installed matches
the specications on the light
sockets.
19
M0114-01 • 02/10/16 • © 2016 Hunter Fan Company
Loading...