Must be able to
secure the fan to
building structure or
fan-rated outlet box
You may need a
friend to help you.
Know your wiring
30 inches
from blade tip
to nearest wall
or obstruction
Assess location
7 feet
from bottom
edge of blade
to the oor
www.HunterFan.com
1.888.830.1326
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or personal
injury, mount fan directly from building structure and/or an
outlet box marked acceptable for fan support of 70 lbs (31.8 kg)
and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch
location. If you cannot lock the circuit breakers in the off
position, securely fasten a prominent warning device, such as a
tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades,
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring,
use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This product may cause interference to radio equipment and
should not be installed near maritime safety communications
equipment, ships at sea, or other critical navigation or
communications equipment operating between 0.45-30 MHz.
This device complies with Part 18 of the FCC Rules.
and the blue wires from the
fan. Connect the white wire
(grounded) from the ceiling to
T
E
K
C
A
R
B
I
G
N
the white wire from the fan.
F
R
O
N
A
F
M
connect the white wire
(grounded) from the
ceiling to the white wire
from the fan.
Connect the black wire
(ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
Refer to CAUTION c.1 on pg. 2
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all three assembly screws could result in the
switch housing xture falling.
Page 11
Light Kit
Light Kit
Switch
Housing
Screw
Notch
www.HunterFan.com
1.888.830.1326
Connect the plugs from the upper and
lower switch housings. Make sure to line
up the colored markings on
the connectors.
Want to install your fan without a light kit?
Go to www.HunterFan.com/FAQs and click
“How do I install my fan without the light kit?”
Partially install two of the switch housing
screws found in the bag. Align the
notches in the sides of the lower switch
housing with the upper switch housing