Hunter Fan HTF2202 Owner Manual

Page 1
30 inches
7 feet
Ladder
Table of Contents
www.HunterFan.com
1.888.830.1326
Congratulations on purchasing your new Hunter® ceiling fan! It will provide comfort
and performance in your home or ofce for
many years. This installation and operation manual contains complete instructions for installing and operating your fan.
We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
What to Expect with
2
6
Tools Needed
PAG E
PAG E
Wiring CanopyDownrod
Light Kit
3
10
Mounting Options
PAG E
PAG E
Maintenance,
Operation & Cleaning
4
11
Ceiling Bracket
PAG E
Blade
PAG E
Troubleshooting
?
PAG E
5
PAG E
12
?
1
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
13
PAG E
PAG E
?
16
PAG E
17
Page 2
What to Expect with Your Installation
www.HunterFan.com
1.888.830.1326
Must be able to secure the fan to building structure or fan-rated outlet box
You may need a friend to help you.
Check box to see fan weight
If you are unfamiliar with wiring, use a
qualied electrician.
Know your wiring
Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.
Assess ceiling angle
30 inches
from blade tip to nearest wall or obstruction
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
7 feet
from bottom
edge of blade
to the oor
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar
with wiring, use a qualied electrician.
c.2 - Use only Hunter replacement parts.
2
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Page 3
Tools Needed
www.HunterFan.com
1.888.830.1326
Ladder
Screwdrivers
Pliers Wire Strippers
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
9/64” Drill Bit
(optional)
3
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Do not discard the hardware bags or mix
parts from different bags. Make note of
the symbol printed on each hardware
bag. The symbols can be used to identify
the appropriate hardware for each step.
Page 4
O
34
CEILING
Mounting Options
www.HunterFan.com
1.888.830.1326
OPTION
If you have a at ceiling:
WALL
Hang your fan by a standard downrod (included).
Standard Mounting
1
Support Structure
Support Structure
OPTION
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
Use the three steps below to determine if your ceiling angle is greater than 34°
Angled Mounting
2
Standard Mounting Style
Ceiling
Outlet Box
(required)
Angled Mounting Style
Ceiling
Outlet Box
(required)
FOLD
on dotted line
1
N
O
I
T
A
U
T
I
S
1
34°
Guide Touches
BOTH Ceiling & Wall
You need ONLY
a Longer
Downrod
*most common
2 3
PLACE
against wall
2
N
O
I
T
A
U
T
I
S
Guide Touches
but NOT Ceiling
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
SLIDE
toward ceiling
Wall
to hang the fan from a at ceiling.
4
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Use Standard Mounting
or Low-Prole Mounting
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
Page 5
Ceiling Bracket
Turn Power
OFF
www.HunterFan.com
For angled ceilings, point
opening toward peak.
1.888.830.1326
Make sure all four bumpers are
still attached.
To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet
box associated with the wall switch location.
Use wood screws (included) when securing to support structure with approved electrical outlet
box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket
with hardware found in
the hardware bag.
5
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
If you are unable to do this,
call Technical Support at
1-888-830-1326.
Refer to warning w.1 on pg. 2
Page 6
Downrod
www.HunterFan.com
1.888.830.1326
Standard Downrod
for ceilings 8-10’ high
Option 1Option 2
Shorter Downrod
for fans installed close to ceiling
Included
(pre-assembled)
Longer Downrod
for angled ceilings or
Option 3
ceilings 10’ or higher
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
1 2 3 4 5
Slide
Slide
678910
Included
Sold Separately
Steps 6-10 to reassemble with new pipe
6
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Page 7
Downrod (continued)
KEEP!
E
E
P
K
www.HunterFan.com
1.888.830.1326
Top Housing
!
Adapter
Remove the pre-installed setscrew so
that the downrod can be inserted.
Thread the wires through the top
housing. Place the top housing onto
the motor housing so that the holes in
the top housing lineup with the holes
in the motor housing and the adapter.
Install the three top housing screws.
8”
7
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
3/8”
Page 8
Downrod (continued)
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
www.HunterFan.com
1.888.830.1326
T
U
C
3/8”
8”
(not to scale)
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
P
I
R
T
S
&
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
of the fan.
If the setscrew is not tightened securely, the fan may fall.
8
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Page 9
Downrod (continued)
DO NOT PICK THE FAN UP BY THE
www.HunterFan.com
1.888.830.1326
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
Note: Fan style may vary.
9
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Page 10
Wiring
F
R
O
M
F
A
N
White
(Ungrounded)
Black
Blue
(Grounded)
F
R
O
M
C
E
I
L
I
N
G
(Ungrounded)
Using an orange wire
connector from
the hardware bag,
connect the 3 grounding
wires (green, green/
yellow stripe, or bare
copper) coming from the
ceiling, downrod, and
hanging bracket.
O
R
F
F
A
M
N
O
R
F
Green/Yellow Stripe
F
R
O
M
C
E
C
M
(Grounding)
Green/Yellow
Stripe
I
L
I
Note: To connect the wires,
www.HunterFan.com
1.888.830.1326
hold the bare metal leads
E
I
L
I
N
G
together and place a wire
connector over them, then twist
E
C
I
L
I
M
N
O
R
F
G
clockwise until tight.
(Grounded)
(Ungrounded)
For Dual Switches
Using the orange wire
connectors from
the hardware bag,
For a Single Switch
Using the orange wire
White
Blue
Black
connectors from
the hardware bag, connect
the black wire (ungrounded)
from the ceiling to the black
and the blue wires from the fan. Connect the white wire
(grounded) from the ceiling to
T
E
K
C
A
R
B
G
N
the white wire from the fan.
F
R
N
O
A
F
M
connect the white wire
(grounded) from the
ceiling to the white wire
from the fan. Connect the black wire (ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
Refer to CAUTION c.1 on pg. 2
Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
10
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Page 11
Canopy
Screw
Holes
www.HunterFan.com
1.888.830.1326
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Lift the canopy into place so that
the screw holes are aligned.
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Insert the two canopy screws
found in the hardware bag.
Note: Fan style may vary.
11
Page 12
Blades
www.HunterFan.com
1.888.830.1326
Put each blade washer, found in
the hardware bag, onto a blade screw,
found in the hardware bag. Then secure
each blade to a blade iron using the blade
screws and washers.
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
12
Page 13
Light Kit
www.HunterFan.com
1.888.830.1326
Partially install two light kit assembly
screws, found in the hardware bag,
halfway into the motor housing as
shown. It does not matter which two
screw holes you choose.
Feed the 9-pin plug connector coming from
the bottom of the motor housing through
the center hole in the light kit assembly.
Connect it to the plug connector found
in the switch housing area of the light kit
assembly. Make sure to line up the colored
markings on the connectors.
13
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Align the keyhole slots in the top of
the light kit assembly with the partially
installed assembly screws. Wrap the
keyhole slots around the screws and
twist counterclockwise.
Page 14
Light Kit (continued)
www.HunterFan.com
1.888.830.1326
Insert a third light kit assembly screw,
found in the hardware bag, into place
and tighten all three screws securely.
Make sure the light kit assembly is securely attached to the motor housing. Failure to properly secure all three assembly
screws could result in the light xture falling.
Carefully push all switch housing
components into the switch housing,
then install the switch housing plate
using two light kit assembly screws,
found in the hardware bag.
14
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Install a bulb into each of the sockets. When
necessary, replace with bulbs of the same wattage.
Page 15
Light Kit (continued)
Tab
Notch
www.HunterFan.com
CONGRATULATIONS!
YOU’RE DONE!
1.888.830.1326
Align the notches in the outer rim of the
globe with the tabs on the light kit assembly
Carefully lift the globe up inside the light
xture as far as it will go. Rotate the globe in
a clockwise direction until it is held tightly in
place by the three tabs.
Remove and discard the plastic connectors
from the ends of the short pull chain. Connect
the appropriate pull chain pendant to each of
the short chains. The fan pull chain controls
the speed: from high to off. The light pull
chain controls the light xture: on and off.
15
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
See next page for fan operation instructions.
Page 16
Maintenance, Operation, & Cleaning
Turn Power
ON
Reverse Switch
www.HunterFan.com
1.888.830.1326
Changing the bulbs - carefully
remove the globe. Unscrew the
bulbs and replace them with
bulbs of the same wattage.
Reinstall the globe.
Changing the direction of
air ow - carefully remove the
globe and move the reverse
switch to the opposite position.
Reinstall the globe.
16
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Cleaning the fan - use soft
brushes or cloths to prevent
scratching. Cleaning products
may damage the nishes.
Page 17
Troubleshooting
www.HunterFan.com
1.888.830.1326
Fan doesn’t work
• Make sure power switch is on.
• Pull the pull chain to make sure it is on.
• Push the motor reversing switch
rmly left or right to ensure that
it is engaged.
• Check the circuit breaker to ensure the power is turned on.
• Make sure the blades spin freely.
• Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram on page 11.
• Check the plug connection in the switch housing.
Excessive wobbling
• Tighten all of the blade and blade iron screws until they are snug.
• Use the provided balancing kit and instructions to balance the fan.
Noisy Operation
• Tighten the blade and blade iron screws until they are snug.
• Check to see if any of the blades are cracked. If so, replace all of the blades.
17
M3609-01 • 05/11/16 • © 2016 Hunter Fan Company
Loading...