Must be able to
secure the fan to
building structure or
fan-rated outlet box
You may need a
friend to help you.
Know your wiring
30 inches
from blade tip
to nearest wall
or obstruction
from bottom
edge of blade
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
7 feet
to the oor
www.HunterFan.com
1.888.830.1326
1.888.830.13261.888.830.1326
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or personal
injury, mount fan directly from building structure and/or an
outlet box marked acceptable for fan support of 70 lbs (31.8 kg)
and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch
location. If you cannot lock the circuit breakers in the off
position, securely fasten a prominent warning device, such as a
tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades,
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
CAUTIONS
Check box to see
fan weight
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring,
use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and if not
installed and used in accordance with the instructions may cause
harmful interference to radio communications.
Tools Needed
www.HunterFan.com
1.888.830.1326
Ladder
PliersWire Strippers
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
Note: To connect the wires, hold
the bare metal leads together and
place a wire connector over them,
then twist clockwise until tight.
www.HunterFan.com
E
C
I
L
M
I
O
R
F
N
G
1.888.830.1326
assembly as shown.
Refer to CAUTION c.1 on pg. 2
Using an orange wire connector
from the hardware bag:
Connect the 3 grounding wires
(green, green/yellow stripe, or bare
copper) coming from the ceiling,
downrod, and ceiling bracket.
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
T
E
K
C
A
R
B
Wiring (continued)
www.HunterFan.com
E
C
R
E
I
M
O
R
F
V
E
R
E
C
I
L
M
I
O
R
F
N
G
1.888.830.1326
Using the orange wire connectors
from the remote control hardware bag:
• Connect the yellow wire from
the receiver to the black wire
from the fan.
• Connect the blue wire from the
receiver to the blue wire (or
possibly black with white stripe
wire) from the fan.
Refer to CAUTION c.1 on pg. 2
yellow
black
F
blue
Using the orange wire connectors
black
(ungrounded)
white (grounded)
from the hardware bag:
F
A
M
N
• Connect the black (ungrounded)
O
R
F
wire from the ceiling to the black
wire from the receiver.
white
white
blue
• Connect the white (grounded)
wire from the ceiling to both the
white wire from the receiver and
black
the white wire from the fan.
F
R
R
N
O
A
F
M
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing xture falling.
Switch Housing (continued)
www.HunterFan.com
CONGRATUALTIONS!
YOU’RE DONE!
1.888.830.1326
Connect the plugs from the upper and
lower switch housings. Make sure to line up
the colored markings on the connectors.
Lift the lower switch housing until its
screw holes are aligned with the screw
holes in the upper switch housing.
Install the three switch housing screws,
found in the hardware bag. Tighten
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
assembly screws could result in the switch housing falling.
To install the transmitter cradle,
remove the two screws holding
your switch cover plate. Do not
remove the cover plate. Orient
the cradle by lining up the two
mounting holes with those on the
cover plate. Insert and tighten the
screws. Do not over tighten.
Operation, Maintenance, & Cleaning (continued)
Hunter fans have the power to cut your cooling costs up
to 40%.
Beat the High Cost of Cooling
The air movement created by a Hunter ceiling fan
lets you set your thermostat higher and still stay
comfortable. Every degree you raise the thermostat
saves up to 7% on energy costs. So, you can cut back on
expensive air conditioning ... and save up to 40%* on
cooling. In winter, your Hunter fan recirculates warm air
and saves up to 10%* on heating bills.
* On average at low speed settings. Your savings may
vary based on climate, building type and thermostat
setting.
Save Energy and Money While Protecting
the Environment
Congratulations! You’re saving energy and money while
protecting the environment by purchasing this ENERGY
STAR qualied Hunter ceiling fan! With this purchase, you
are doing your part to protect the environment.
Your new ceiling fan has earned the ENERGY STAR label
because it meets high energy efciency specications
set by the Environmental Protection Agency (EPA).
ENERGY STAR labeled ceiling fans save energy because
they have more efcient fan motors and air delivery due
to more aerodynamic blade congurations. Ceiling fan
models bearing the ENERGY STAR label move air 14 -
20% more efciently than typical ceiling fan models.
For more information on ENERGY STAR visit
www.energystar.gov.
• Push the motor reversing switch
rmly left or right to ensure that it
is engaged.
• Check the circuit breaker to
ensure the power is turned on.
• Make sure the blades spin freely.
• Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on pages 10-11.
• Make sure the battery is working.
• Check the plug connection in the
switch housing.
Excessive wobbling
• Tighten all of the blade and
blade iron screws until they
are snug.
• Turn the power off, support
the fan carefully, and check
that the hanger ball is properly
seated.
• Use the provided balancing
kit and instructions to balance
the fan.
Remote control of fan is erratic
• Make sure the battery is
installed correctly.
• Install a fresh battery.
Transmitter only works when held
at close range
• Change battery.
Noisy operation
• Tighten the blade and blade iron
screws until they are snug.
• Check to see if any of the blades
are cracked. If so, replace all of
the blades.
If you have multiple remotes or
multiple remote-controlled fans
installed on the same circuit
breaker and you are experiencing
interference or faulty operation of
your remote controls, please go to
www.HunterFan.com/FAQs
and click “How do I properly install
multiple remote-controlled fans?”
for information on how to correct
this issue.