Hunter Fan Anchorage, 50497 Installation Manual

Model: 50497 Matte Black Fan weight ±2 lbs: 17.9 lbs (8.1 kg)
Anchorage
Installation Manual
©2020 Hunter Fan Co.
PG3868 r020620
Congratulations on purchasing your new Hunter® ceiling fan!
Here are the tools you’ll need to complete your installation:
The ceiling fan you purchased will provide comfort and performance in your home or ofce for many years. This instruction manual contains
WARNING
complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
We are here to help!
This Instruction Manual is designed to make installation as simple as possible. While working through this Instruction Manual, keep your smartphone or tablet nearby. We have added video links to help you through the more technical sections. If you are unfamiliar or uncomfortable with wiring, contact a qualied electrician. We also provide telephone support at 1.888.830.1326 or visit us at HunterFan.com.
READ and SAVE These Instructions
Warning
w.1 - To reduce the risk of re, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 – To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch. w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
Caution
c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualied electrician. c.2 - Use only Hunter replacement parts.
Ladder
This product conforms to UL Standard 507.
OPTIONAL
If mounting to a support structure, you will also need these tools.
Screwdriver
Pliers
1
© 2020 Hunter Fan Company 7130 Goodlett Farms Pkwy, Suite 400
Wire Strippers
Memphis TN 38016
9/64” Drill BitDrill
1886
We recommend that you pull everything out of the box and lay it out. We have
Here is what comes in your box:
grouped the drawn components below with the hardware you’ll need for those parts. The screws below are drawn to scale to make it easier to identify what piece of hardware is needed to install each component.
Hunter Pro Tip:
Do not discard the hardware bags or mix parts from different bags. Make note of the symbol printed on each hardware bag. The symbols can be used to identify the appropriate hardware for each step.
bag
Washer
x2
For installing the hanger bracket and wiring the fan
x14 x14
bag bag
Blade
x7
Wood Screw
Wire Nut
x2
x4
Blade ScrewBlade Washer
Ceiling Bracket
Canopy
Downrod
Motor
bag
For installing the canopy
Canopy Screw
x2
x4
Housing Screw
bag
Lower Switch Housing Cap
For installing the blades
x2 x3
Wall Control Extra Downrod
bag
For your convenience, you may receive extra fasteners.
Spare Parts
Note:
Fan style may vary.
Find a part that is missing or damaged?
Don’t take it back to the store. Let us make it right. Visit us at HunterFan.com or call us at 1.888.830.1326.
M3794-01 r020620
2
1886
1886
Choosing the Right Installation Location
Checking the Ceiling Angle:
Angled Mounting
You probably bought this fan with a location in mind. Let’s check below to make sure it is a good t.
Installing the Ceiling Bracket
Installing the Downrod
Check the room dimensions: Check the outlet box:
30 inches
from blade tip to nearest wall or obstruction
7 feet
from bottom edge
of blade to the
oor
Standard Mounting
Support Structure
Outlet Box
(required)
Ceiling
You must be able to secure the fan to building structure or fan-rated outlet box.
Support Structure
Angled Mounting
Ceiling
Outlet Box
(required)
If you have a at ceiling:
Hang your fan by a standard downrod. Some fans come with a shorter downrod for a Low Prole installation.
A little more information on Angled Mounting:
For optimum performance and appearance, a longer downrod should be used with your Hunter ceiling fan when installing on high or angled ceiling. If your ceiling is angled greater than 34° you will also need an Angled Mounting Kit. Longer downrods and the Angled Mounting Kit are sold separately at HunterFan.com.
Hunter Pro Tip:
Determining if you need an Angled Mounting Kit:
Fold on the dotted line. Place edge against the wall. Slide towards the ceiling.
If the guide touches the wall but not the ceiling, you need an angled mounting kit.
WALL
If you have an angled or vaulted ceiling:
1. You will need a longer downrod. (sold separately at HunterFan.com)
2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit. (Sold separately at HunterFan.com)
3
34°
CEILING
Loading...