Installation
Ceiling
Plate
Receive
r
Canopy
Receiver
Canopy
Ceiling Bracket
Receiver
Fan Body
Cable Tie
For low prole fans, the receiver should be secured to the ceiling bracket with a cable tie.
Receiver
Canopy
Turn Power
Universal ON/OFF Ceiling Fan Remote
Model 99118
OR OR OR
www.HunterFan.com
1.888.830.1326
If you are installing multiple remote-controlled fans
on the same circuit breaker,
you may need to perform a few extra steps to prevent
interference or faulty operation of your remote controls.
Go to www.HunterFan.com/FAQs and click “How do I properly
install multiple remote-controlled fans?” for more information.
OFF
Before installing the
Universal Remote Control
Receiver, use the pull chains to set the fan speed to HIGH and the light to ON. Be sure power is OFF before proceeding with installation.
Wiring
E
C
R
E
M
O
R
F
I
Remove the canopy. If uncertain how to remove it, reference the fan’s owner’s manual. With wiring exposed, it may be helpful to note existing wire connections or take a digital photo for reference. Remove the wire connectors that connect the wires from the outlet box to the fan, leaving the grounding wires connected.
V
E
R
blue
yellow
blue
black
Choose the hanging system that most closely resembles the one used by your fan and install the receiver as shown and wire as directed.
Note: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire, leaving a minimum of 8” remaining. Re-strip the fan lead wires 1/2”. Place remaining excess
wire into the ceiling electrical box. The bracket and fan must remain properly grounded.
You may have installation issues if the fan is installed on an angled ceiling. For assistance, call 1-888-830-1326.
E
C
R
E
I
M
O
R
F
M
F
O
R
F
A
N
R
F
V
E
R
C
E
I
L
M
O
R
black
white
M
F
O
A
N
white white (grounded)
black (ungrounded)
F
I
N
G
CONNECT WIRES FROM RECEIVER TO FAN - Using the orange wire connectors, connect the blue wire from the
receiver to the blue wire (or possibly black with white stripe wire) from the fan. Connect the yellow wire from the
receiver to the black wire from the fan.
If you’re uncertain about wire colors or connections, please contact a qualied electrician.
the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely
To avoid possible electrical shock, before installing or servicing your fan, disconnect
fasten a prominent warning device, such as a tag, to the service panel.
CONNECT WIRES FROM RECEIVER AND FAN TO WIRES FROM OUTLET BOX - Using the orange wire connectors,
connect the black wire (ungrounded) from the ceiling to the black wire from the receiver. Connect the white wire
(grounded) from the ceiling to both the white wire from the receiver and the white wire from the fan.
AFTER ALL WIRES ARE CONNECTED and secured with wire connectors, re-install the canopy.
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
M0057-01 • 01/15/14 • © Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Maintenance
Battery Door
Phillips Head Screw
Installing or changing the battery
To access the battery compartment remove the small Phillips head screw that secures the battery door to the transmitter assembly. Replace with a
CR2032 battery when necessary. The
battery should be installed with the positive (+) side up.
Turn Power
ON
IMPORTANT
Use the pull-chain switch on the fan to set the fan speed to the HIGH position before operation.
TroubleshootingSafe-Exit
Pairing
Fan OFF Fan ON
Note: The remote must be paired before the fan will operate.
Within 3 minutes of restoring power to the fan, press both the Fan OFF button and the Fan ON button for at
least 4 seconds. Your fan will turn on to
indicate successful syncing. If it does not, turn off power to your fan, wait 1 minute then try again. If using the transmitter with multiple fans, repeat this process for each fan.
Operation
Fan
Control
Light
Control
Fan Operation:
Press and quickly release the ON or OFF button on the remote control to turn the fan OFF or ON.
To change the fan speed, slowly pull the fan pull-chain switch to select the desired speed.
Light Operation:
Press and quickly release the ON or OFF button on the remote control to turn the light OFF or ON. (Light will come ON at maximum brightness.)
The Safe-Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the
lights go out. To use Safe-Exit:
• Press the fan OFF button for at
least three seconds to initiate the Safe-Exit Mode.
• The lights will ash for visual conrmation.
• The lights will stay on 50%
brightness for 15 seconds and then begin to dim. After a total of 30 seconds, the lights will be completely off.
Note: For CFL lighting, the lights will stay on 100% brightness
for 30 seconds. After a total of 30 seconds, the lights will be completely off.
Fan will not start
Make sure the power is on at the circuit breaker and the wall switch.
• Make sure the battery is working.
• Make sure that the transmitter and
receiver are paired.
• Check wire connections inside of
the canopy.
Remote control of fan is erratic
Make sure the battery is installed correctly.
• Install a fresh battery.
Transmitter only works when held at close range
• Change battery.
Lights do not dim
• Check to see if a CFL bulb is
installed. The control has a feature
that automatically detects CFL bulbs and turns off dimming if a CFL bulb
is installed.
CFL bulbs icker
• Turn the light switch off and back
on. Within three minutes, hold down the Fan Off button while pressing the Light Off button twice. If the problem is not corrected, repeat the process up to three times.
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser of the Control (“Control”): Your Control is warranted to be free from defects in material and workmanship for a period of one year from the date of sale. If the Control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace it free of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL. This warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us, mishandling, improper installation,
modications, or damage to the Control while in your possession, or unreasonable use.
This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty batteries. To obtain a replacement, return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 7130 Goodlett Farms Pkwy., Memphis, TN 38016. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
If you have problems installing or operating your fan, do not return this
product to the dealer. Call our Consumer Affairs Hotline.
1-888-830-1326
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for
help. Note: Any changes or modications to the transmitter or receiver
not expressly approved by Hunter Fan Company may void one’s authority to operate this remote control.
M0057-01 • 01/15/14 • © Hunter Fan Company
Loading...