W A R N I N G
TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
1. Use this unit only in a manner intended by the manu­facturer. If you have questions, contact the manufac­turer at the phone number or address listed in the warranty.
2. Before installing, servicing, or cleaning the unit, disconnect the power by turning o the circuit break­ers to the outlet box and associated wall switch loca­tion. If you cannot lock the circuit breakers in the o position, securely attach a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.
5. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.
6. Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.
7. Install fan at least 5 feet (1.52 m) above the floor.
8. Never place a switch where it can be reached from a tub or shower.
9. This unit must be grounded.
C A U T I O N
1. For general ventilating use only. Do not use for ventilating hazardous or explosive materials.
2. To avoid motor bearing damage and noisy/unbal­anced impellers, keep drywall spray, construction dust, etc. off power unit.
3. DO NOT install this product in a wall. This prod­uct is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.
4. Please read specification label on product for fur­ther information and requirements.
W A R N I N G
DISCONNECT
ELECTRIC POWER SUPPLY AND LOCK OUT
SERVICE PANEL
BEFORE
SERVICING UNIT
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.
2
42929-01 10/26/2010
Check all the parts.
If damaged, call 1-888-830-1326
for replacements.
x4
A
B
*
3/8” Cable Connector
95044-01-096
E
95029-01-000
F
77481-01-000
G
03242-01-232
H
95491-06-000
I
74508-03-133
J
77521-01-000
K
C
*
x2
*
D
NOTE:
Strain relief cable connector must be installed. Not Included.
Extra Screws
Before Installation
65219-01-000
L
97258-01-000
M
75184-01-092
N
97260-01-000
O
76079-02-481
P
Tools Needed. (Not supplied.)
Estimated assembly time: 30 to 60 minutes
NOTE: Remove all packing materials before installation.
1
42929-01 10/26/2010
Turn off the power source.
2
J
F
Loosen screws.
3
5
3
6
42929-01 10/26/2010
4
I
F
Remove the motor/blower from the housing.
Remove the pre-loaded screw tip covers.
Remove packing material.
Back out the pre-loaded screw tips until flush
with the side of the housing.
7
8
G
H
Remove the wiring cover screw.
4
Remove the wiring cover.
42929-01 10/26/2010
9
10
F
C
B
Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and
secure with washer.
Choose Installation Option
For New Construction - attaching to joist go to step A11, page 5
For New Construction - suspended between joists go to step B11, page 8
For Existing Construction - accessible from above go to step C11, page 11
For Existing Construction - accessible only from below go to step D11, page15
New Construction - attaching to joist
A11
Position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
42929-01 10/26/2010
5/8 1/2
A12
F
5/8 1/2
Screw pre-loaded screws into joist or framing.
5
A13
42929-01 10/26/2010
Route wires through the strain relief.
A14
A15
Black
2 Pin
White
Fan Motor
White
3 Pin
Light
*Option Fan & Main Light Together
Black
*Option
Light
Connect wires as shown.
A16
0
Ground
Green
A
Bare Copper
Black
Main Switch 1 (AC In)
White
Black
Switch 2 (AC In)
F
H
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.
6
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
42929-01 10/26/2010
0000
A17
A18
0000
I
Connect wiring harness. DO NOT ALLOW THE MOTOR TO
HANG FROM THE WIRING HARNESS.
A19
J
Secure the motor by tightening the 2 screws.
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched
between the motor and the housing.
A20
Turn on the power source.
A21
Test the motor. If the motor does not run, check the plug
42929-01 10/26/2010
ON
connection.
OFF
A22
Go to step
E1
on page 17
to attach grille.
7
New Construction – suspended between joists
5/8 1/2
42929-01 10/26/2010
B11
B13
F
Slide the mounting rails into brackets.
B12
E
5/8 1/2
Position the correct depth mark at the bottom edge of
the joist based on the thickness of your sheetrock.
B14
F
Mark position of screws by using holes as a template.
B15
1/8” bit
Drill a hole in the center of each outline.
B16
8
Insert screws, leaving space between the screw
head and the joist. Screws are not provided.
Attach the rails onto the screws.
42929-01 10/26/2010
B17
B18
Tighten screws. Route wires through the strain relief.
B19
B20
Black
2 Pin
White
Fan Motor
White
3 Pin
Light
*Option Fan & Main Light Together
Black
*Option
Light
Connect wires as shown.
B21
Ground
Green
A
Bare Copper
Black
Main Switch 1 (AC In)
White
Black
Switch 2 (AC In)
H
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the
42929-01 10/26/2010
wiring cover plate.
G
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
9
B22
42929-01 10/26/2010
B23
I
Connect wiring harness. DO NOT ALLOW THE MOTOR TO
HANG FROM THE WIRING HARNESS.
B24
J
I
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched
between the motor and the housing.
B25
10
Secure the motor by tightening the 2 screws.
B26
ON
Test the motor. If the motor does not run,
check the plug connection.
OFF
Turn on the power source.
B27
Go to step
E1
on page 17
to attach grille.
42929-01 10/26/2010
Existing Construction – accessible from above
5/8 1/2
C11
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
EXISTING FAN
motor housing (8”x 8 1/2”).
NO EXISTING FAN
OR
Use the motor housing as a template to mark position.
C12
F
C13
8”
Cut out an opening for the housing.
8 1/2”
5/8 1/2
E
Slide the mounting rails into brackets.
C14
Position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
42929-01 10/26/2010
Mark position of screws by using holes as a template.
11
C15 C16
42929-01 10/26/2010
C17
Drill a hole in the center of each outline. Insert screws, leaving space between the screw head
and the joist. Screws are not provided.
C18
Attach the rails onto the screws. Tighten screws.
12
C19
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may
need to be purchased.
C20
Route wires through the strain relief.
42929-01 10/26/2010
C21
Tighten the strain relief screws.
C22
C23
Black
2 Pin
White
Fan Motor
White
3 Pin
Light
*Option Fan & Main Light Together
Black
*Option
Light
Connect wires as shown.
C24
Ground
Green
A
Bare Copper
Black
Main Switch 1 (AC In)
White
Black
Switch 2 (AC In)
H
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the
42929-01 10/26/2010
wiring cover plate.
G
I
Connect wiring harness. DO NOT ALLOW THE MOTOR TO
HANG FROM THE WIRING HARNESS.
13
C25
42929-01 10/26/2010
C26
I
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched
between the motor and the housing.
C27
Turn on the power source.
J
Secure the motor by tightening the 2 screws.
C28
ON
OFF
Test the motor. If the motor does not run,
check the plug connection.
14
C29
Go to step
E1
on page 17
to attach grille.
42929-01 10/26/2010
Existing Construction – accessible only from below
D11
Remove an existing fan and check to make sure the open­ing is large enough to accommodate the new motor hous-
EXISTING FAN
ing (8”x 8 1/2”).
D13
D12
F
Move the housing into position above the ceiling
D14
D15
Route wires through strain relief.
2
1
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.
Install the housing flush with the sheetrock and secure by
tightening the pre-loaded screws into the joist.
42929-01 10/26/2010
F
15
D16
42929-01 10/26/2010
Black
2 Pin
White
Fan Motor
White
3 Pin
Light
*Option Fan & Main Light Together
Black
*Option
Light
Connect wires as shown.
Ground
Green
A
Bare Copper
Black
Main Switch 1 (AC In)
White
Black
Switch 2 (AC In)
D17
G
H
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under
the wiring cover plate.
D19
D18
I
Connect wiring harness. DO NOT ALLOW THE MOTOR TO
HANG FROM THE WIRING HARNESS.
D20
16
I
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched between
the motor and the housing.
J
Secure the motor by tightening the 2 screws.
42929-01 10/26/2010
D21
D22
ON
OFF
Turn on the power source.
D23
Go to step
E1
on page 17
to attach grille.
Attaching the Grille
Test the motor. If the motor does not run, check the plug
connection.
E1
N
42929-01 10/26/2010
E2
F
M
Remove the thumbscrews. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO
HANG FROM THE WIRING HARNESS.
17
42929-01 10/26/2010
E3
E4
E5
M
Remove the strain relief bracket screw. Position the strain relief bracket under the
motor as shown.
M
E6
M
K
M
18
Insert the strain relief bracket’s dog-leg tab so that
it hooks over the lip of the motor. Reinstall the
strain relief bracket screw.
E7
N
Attach thumbscrews.
WARNING: To reduce the risk of electrical shock,
all 4 thumbscrews MUST be properly installed.
Align posts A, B, C and D (stamped into motor hous-
ing) with posts A, B, C and D (stamped into light
fixture). Slide light fixture over posts.
E8
Install bulbs (not included).
42929-01 10/26/2010
E9
E10
O
P
Align glass dome and push up.
Complete.
Screw finial into position.
42929-01 10/26/2010