Hunter Fan 51011, 51010, 53064, 53070, 53069 User Manual

...
30 inches
7 feet
Ladder
Table of Contents
www.HunterFan.com
1.888.830.1326
Congratulations on purchasing your new Hunter® ceiling fan! It will provide comfort and performance
in your home or ofce for many
years. This installation and operation manual contains complete instructions for installing and operating your fan.
We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
To register your fan please visit: www.HunterFan.com/register
Blades Troubleshooting
Your Installation
Tools Needed
PAG E
2
Preparation
PAG E
Downrod
6
Switch Housing Light Kit
3
7
Mounting Options
PAG E
Wiring Canopy
PAG E
Maintenance
& Cleaning
4
10
Ceiling Bracket
PAG E
PAG E
?
PAG E
5
PAG E
11
?
12
PAG E
13
PAG E
14
PAG E
PAG E
?
16
PAG E
17
1
M0002-01 • 11/06/12 • © Hunter Fan Company
What to Expect with Your Installation
www.HunterFan.com
1.888.830.1326
Must be able to secure the fan to building structure or fan-rated outlet box
You may need a friend to help you.
Check box to see fan weight
If you are unfamiliar with wiring, use a
qualied electrician.
Know your wiring
Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.
Assess ceiling angle
30 inches
from blade tip to nearest wall or obstruction
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
7 feet
from bottom
edge of blade
to the oor
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar
with wiring, use a qualied electrician.
c.2 - Use only Hunter replacement parts.
2
M0002-01 • 11/06/12 • © Hunter Fan Company
Tools Needed
www.HunterFan.com
1.888.830.1326
Ladder
Pliers Wire Strippers
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
9/64” Drill Bit
(optional)
3
M0002-01 • 11/06/12 • © Hunter Fan Company
Screwdrivers
O
34
CEILING
Mounting Options
www.HunterFan.com
www.HunterFan.com
1.888.830.1326
1.888.830.1326
OPTION
If you have a at ceiling:
WALL
Hang your fan by a standard downrod (included).
Standard Mounting
1
Support Structure
Support Structure
OPTION
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
Use the three steps below to determine if your ceiling angle is greater than 34°
Angled Mounting
2
Standard Mounting Style
Ceiling
Outlet Box
(required)
Angled Mounting Style
Ceiling
Outlet Box
(required)
FOLD
on dotted line
1
N
O
I
T
A
U
T
I
S
1
34°
Guide Touches
BOTH Ceiling & Wall
You need ONLY
a Longer
Downrod
*most common
2 3
PLACE
against wall
2
N
O
I
T
A
U
T
I
S
Guide Touches
but NOT Ceiling
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
SLIDE
toward ceiling
Wall
4
4
4
M0002-01 11/06/12 © Hunter Fan Company
M0002-01 • 11/06/12 • © Hunter Fan Company
Use Standard Mounting
or Low-Prole Mounting
to hang the fan from a at ceiling.
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
Ceiling Bracket
Turn Power
OFF
www.HunterFan.com
For angled ceilings, point
opening toward peak.
1.888.830.1326
Make sure all four (4) bumpers
are still attached.
To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet
box associated with the wall switch location.
Use wood screws (included) when securing to support structure with
approved electrical outlet box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket
with hardware found in
the hardware bag.
5
M0002-01 • 11/06/12 • © Hunter Fan Company
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
If you are unable to do this,
call Technical Support at
1-888-830-1326.
Refer to warning w.1 on pg. 2
Ceiling Bracket (continued)
Preparation
E
E
P
K
!
D
I
S
C
A
R
D
Remove the shipping blocks from the motor. Save the screws. They
will be needed for blade iron
installation.
www.HunterFan.com
www.HunterFan.com
1.888.830.1326
1.888.830.1326
Time Saver Tip: Get a helper
to insert grommets, found in
the hardware bag, into the
blades while you’re doing the
next couple of steps.
6
M0002-01 • 11/06/12 • © Hunter Fan Company