Hunter Fan 44660 User Manual

44660/44668 PROGRAMMABLE THERMOSTAT INSTALLATION
is easy installation guide will walk you through the proper installation of your Hunter® thermostat. For questions or assistance you may contact our technical department at 1-888-830-1326 (CAN 1-866-268-1936) . Hours of operation are 7 a.m. to 7 p.m. Monday thru Friday and 8 a.m. to 5 p.m. on Saturday.
* Often, 2 wire heat only systems do not have terminal
labels. Connect 1 wire to the RH terminal and the other to W.
* If both "O" and "B" are present, "B" may be a common
wire. Contact our technical support department for wiring assistance.
OLD
THERMOSTAT
NEW
THERMOSTAT
W/B
W, W/b
2-5. Remove the wall plate and drill two 3/16” holes where
marked.
Note: Do not let the terminal stickers come loose while removing the wallplate.
2-6. Tap the plastic anchors into the holes with a hammer
until they are flush with the wall.
2-7. Reposition the wall plate on the wall, pulling the wires
through the opening. Insert the mounting screws through the wall plate and into the anchors. Verify that the wall plate is visually level and securely tighten both screws.
CAUTIONS / WARNINGS
* Do not disconnect the wires from your old thermostat
until all wires have been properly labeled. You must label all wiring accordingly, wire color may not
indicate the function of the wire.
* Most thermostats are low voltage, and present no threat
to you during the uninstallation or installation process. As a precaution though, turn off the power to your Furnace by using the switch on the side or your breaker box.
* is thermostat is designed for use with 24 volt AC/
millivolt systems with a maximum of 1 amp. Higher
amp or line voltage systems will cause damage to your system and increase the risk of fire.
TOOLS
Gather all tools necessary to complete your installation before removing the old thermostat.
To install your thermostat you should have the following tools:
Slotted Screwdriver
Phillips Screw Driver
Electric Drill and 3/16” drill bit
Hammer
Four 1.5v (AA) size alkaline batteries
Unpack your new Hunter® thermostat and ensure all components are present in the Accessory Pack. is includes:
2 - #8 slotted screws
2 - wall anchors for mounting
1 - sheet of terminal labels
1 - jumper wire
1 - thermostat with mounting plate.
REMOVING THE OLD THERMOSTAT
1-1. Turn off power to your furnace.
1-2. Remove the existing cover. Some thermostats may
have screws or other locking devices that must first be removed. Once the wallplate is exposed, locate the wire terminals. If the wire terminals are not visible, they may be connected to the back of the wallplate. Look for any additional screws, tabs, or locking devices to remove the wallplate.
Warning: Do not remove any wires from the existing thermostat until you have labeled all wires with the included terminal stickers.
W
G
Y
RC
G
Y
RC
Wallplate
Steps 1-1. - 1-2.
ermostat
W
ermostat Cover
CoverWallplate
LABELING WIRES
Y/O
Y, Y/O, Y1
G, F
G
RH
RH, R1
RC
RC, R
O
O
Not Used
C
Warning: Many 2 wire heat only systems are line voltage.
To determine this, check the size of the wire. If the wire is much larger than the jumper wire included with this thermostat do not connect to the thermostat.
Note: If you have any addition wires that do not match
with the wiring diagrams in this manual, contact our technical support department for assistance.
Warning: Never connect a “common wire” to this
thermostat, sometimes referred to as “C” or “B”. Doing
so could cause damage to the thermostat or your heating/cooling system. Contact our technical support department for wiring assistance.
INSTALLING THE MOUNTING PLATE
2-1. Separate the wallplate from the thermostat by
gripping the thermostat firmly on the top and bottom with one hand. With the other hand, press the release tab on the bottom of the thermostat. Pull firmly to release the two parts from each other.
Step 2-1.
2-2. Position the wallplate on the wall and pull the wires
through the opening on the mounting plate.
2-3. Level the mounting plate for appearance.
2-4. Mark holes for plastic anchors provided by using a
pencil to place a mark on the wall if your existing holes do not line up with those on the Hunter wallplate.
RH
W
G
Y
RC
Step 2-7.
WIRE INSTALLATION
A jumper wire has been included on the mounting plate between the RH and RC1 terminals. is jumper should remain between these 2 terminals unless RH and RC each have their own wire. Consult the diagram for "5 Wire Heat / Cool" on the back of this page.
3-1. Loosen but do not remove the screws on the terminal block.
NOTE: Ensure the ends of the wires have enough exposed wire to insert into the terminal block.
3-2. Insert each wire into the appropriate terminal and tighten the screw.
Note. Consult the wiring charts under "Wiring Diagrams" on the backside of this sheet to ensure proper wiring.
3-3. Gently pull each wire to ensure they are properly secured.
Steps 3-1. - 3-2.
FINISHING INSTALLATION
4-1. Locate the SW1 switch on the back of the thermostat. If you have a gas/oil heating system, move this switch to the HG (Heating Gas) position, electric based systems should be set to HE (Heating Electric), and single stage heat pumps (SSHP) should be set to SSHP.
SW1
Step 4-1.
4-2. Once all the wiring and settings have been made on the backplate and backside of the thermostat, place the top of the thermostat at an angle over the two tabs on the wall plate. Press the thermostat onto the wall plate and press to snap the bottom tab into place.
Note: Do not force the thermostat onto the wall plate, as the terminal pins may be damaged. If the thermostat does not snap into place properly, the unit may not work.
4-3. Insert two AA alkaline batteries.
4-4. Restore power at the electrical panel or furnace.
TECHNICAL SUPPORT
* Using the chart below, label the wires one at a time from
your old thermostat with the included terminal stickers and remove them from the thermostat.
Steps 2-2. - 2-4.
* To ensure wires do not fall back into the wall hole, you
may tape them to the wall, or wrap them around a pencil.
©2009 Hunter Fan Company 43078-01 • 04/15/09
You may contact our Consumer Services department at 1-888-830-1326 (CAN 1-866-268-1936) or over the Internet at www.hunterfan.com/customer-care-center. aspx/ for support or manuals. Hours of operation are 7 a.m. to 7 p.m. Monday thru Friday and 8 a.m. to 5 p.m. on Saturday.
Y1
RC
RH
Y1 Heat Valve (SSHP)
4 Wire Heat / Cool
W/B
ermostat Backplate
W/B
ermostat Backplate
RH
RC1
RC
Y/O
G
Y1
RH
RC1
RC
Y/O
G
RC
RC
Y/O
W/B
G
RH
RC
Y/O
W/B
G
OR
RH, 4 Heat 24V Supply
Jumper Wire Only Jumper
RC, R Cool 24V Supply
O, Y/O, M Cool Contactor
W/B, W, W1 Heat Relay / Valve
G, F Fan Relay
Y1 Heat Valve (SSHP)
RH, 4 Heat 24V Supply
Jumper Wire Only Jumper
RC, R Cool 24V Supply
O, Y/O, M Cool Contactor
W/B, W, W1 Heat Relay / Valve
G, F Fan Relay
Wall
5 Wire Heat / Cool
Wall
W/B
ermostat Backplate
Y1
RH
RC1
RC
Y/O
G
Y1
RH
RC1
RC
Y/O
RH
W/B
RC
Y1 Heat Valve (SSHP)
RH, 4 Heat 24V Supply
Jumper Wire Only Jumper
RC, R Cool 24V Supply
O, Y/O, M Cool Contactor
W/B, W, W1 Heat Relay / Valve
G, F Fan Relay
Y1 Heat Valve (SSHP)
RH, 4 Heat 24V Supply
Jumper Wire Only Jumper
RC, R Cool 24V Supply
O, Y/O, M Cool Contactor
2 Wire Heat Only
Wall
3 Wire Heat Only
Wall
W/B
ermostat Backplate
W/B
ermostat Backplate
G
Y1
RH
RC1
RC
Y/O
G
W/B
G
RC
Y/O
G
W/B, W, W1 Heat Relay / Valve
G, F Fan Relay
Y1 Heat Valve (SSHP)
RH, 4 Heat 24V Supply
Jumper Wire Only Jumper
RC, R Cool 24V Supply
O, Y/O, M Cool Contactor
W/B, W, W1 Heat Relay / Valve
G, F Fan Relay
3 Wire Cool Only
Wall
ermostat Backplate
Y1
RH
RC1
RC
Y/O
W/B
G
Y1
RC
Y/O
G
Y1 Heat Valve (SSHP)
RH, 4 Heat 24V Supply
Jumper Wire Only Jumper
RC, R Cool 24V Supply
O, Y/O, M Cool Contactor
W/B, W, W1 Heat Relay / Valve
G, F Fan Relay
Single Stage Heat
Pump
Wall