Thank you for choosing a Hunter programmable thermostat. Your
new Hunter thermostat will provide years of reliable service and
year-round energy savings.
Please read this manual before beginning installation and save this
booklet for complete operation instructions.
The Hunter Technical Support Group is available from 7 am to 7 pm Monday
- Friday and 8:00 to 5:00 Saturdays CST. They may be reached toll-free at
1-888-830-1326.
4
important information
This thermostat is designed to work on the following
heating and cooling systems:
Gas – Standing Pilot
Gas – Electronic Ignition
Gas – Fired Boilers
Gas – Millivolt Systems
Oil – Fired Boilers
Oil – Fired Furnace
Electric Furnace
Electric Air Conditioning
Single-Stage Heat Pumps
This thermostat is not designed for multi-stage heat pump systems
or 110/220 V baseboard heating systems.
If you are unsure what kind of heating and cooling system you
have, please contact a qualied HVAC Technician for assistance.
5
tools
This thermostat includes two #8 slotted screws and two wall
anchors for mounting.
To install your new thermostat, you will need the following supplies:
NOTICE! Do not disconnect the wires from the existing
thermostat before reading these instructions. The wires
must be labeled prior to removal to ensure proper
reconnection.
7
W
G
Y
RC
W
G
Y
RC
8
uninstalling the existing unit
1. Turn the system power OFF from the existing thermostat. Turn
the power to the HVAC system OFF at the main power panel or
at the furnace.
(Failure to turn off the power to the existing thermostat before
removal could damage your system.)
2. Remove the existing thermostat cover to access the wires from
the wall.
(Some thermostats may have multiple covers, screws or other
locking devices that must be removed or disengaged. See page
8 for common examples.)
3. Locate, but do not disconnect the wires.
(If wires are not visible, they may be connected to the back
of the wall plate. Some models may have doors that open to
expose the wires and mounting screws.)
9
if your existing thermostat
is marked...
label the wire with
this sticker:
G / F
G
G
W / H / B
W/B
W/B
Y / C* / M / O
Y/0
Y/0
RC / VC
RC
RC
RH / R / VR / 4
RH
RH
24 Volt
24 Volt cool
air conditioning
compressor
heating
fan
Y1
Y1
Y1
heat pump compressor
wire labels
10
uninstalling the existing unit, cont.
4. Using the provided stickers, label each wire according to the
Y
RC
5. Do not let the wires slip back into the wall during disconnection.
You may want to secure the wires to the wall as you disconnect
them. After all wires are labeled, disconnect each wire and
remove the existing wall plate.
(Any unused wires should be capped with an approved electrical connector,
such as electrical tape.)
Wire Labels chart.
(If the terminals are not labeled,
contact a qualied HVAC technician.)
Note: Wire colors do not always comply with standards, so
wire color should be ignored. Refer to the existing terminal
W
W
designation for proper identication.
G
*If wires marked Y & C are both present, C may be a
Common wire and should not be used. If you have a wire
marked C, do not connect it to any terminal. This wire is used only
for non-battery powered thermostats.
11
Y/0
G
W/B
RC
Y1
12
installing the thermostat
INSTALLING THE WALL PLATE
1. Remove the wall plate from the new thermostat by pressing the
release tab on the bottom of the thermostat.
2. Position the new wall plate on the wall and pull the labeled wires
through the opening.
3. If the existing holes do not match those on the Hunter wall plate,
or if there are no existing holes, visually level the wall plate and
mark the wall for two holes.
13
Y
G
W
RC
14
installing the thermostat, cont.
4. Remove the wall plate and drill two 3/16” holes where marked.
5. Tap the plastic anchors into the holes until they are ush with the
wall. (Do not use plastic anchors if you encounter a stud in the
wall.)
6. Reposition the wall plate on the wall, pulling the wires through
the opening. Insert the mounting screws through the wall plate
and into the anchors. Verify that the wall plate is visually level
and securely tighten both screws.
15
Y/0
RC
Y1
G
W/B
RC RH
G
Y/0
W/B
Y1
Terminal Shield
16
INSTALLING THE THERMOSTAT, CONT.
CONNECTING THE WIRES
Jumper
G RC RH YW
Note: A jumper wire has been provided, connecting the
RC and RH terminals for systems that do not provide both
an RH and RC wire. If you have both an RH and RC wire,
remove this jumper. If you do not have both an RH and RC
wire, leave the jumper in place.
2. Match and connect the wires from the wall to the
terminals as shown. Wires should be inserted behind the black
terminal shields. Tighten each screw after the connection has
been made.
1. Loosen, but do not remove, the terminal screws.
(The ends of any extra wires should be individually wrapped in electrical
tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the wall to prevent
interference.
17
Thermostat
Cover
System
Switch
Fan
Switch
T
AM
4
HEAT
Y1
W/B Y/O RH RC G
ENABLE
RECOVERY
DISABLE
STD
FAN OPTION
HP
SYSTEM TYPE
HG
HE
18
AUTO REcOvERY
SYSTEM TYpE
installing the thermostat, cont.
ATTACHING THE THERMOSTAT
Lift the thermostat cover and set the SYSTEM switch to OFF and
the FAN switch to AUTO.
1. Fan option - Locate the HE/HG switch on the back of the
thermostat. Set the switch to HG (default) for gas furnace and oil
burners. Set the switch to HE for electric furnaces. (The switch
has no effect when the system is set to cooling mode.)
2. Recovery - Locate the
thermostat. If you wish to use the Auto Recovery feature, verify
that the switch is in the ENABLE position. If you do not wish
to use this feature, simply change the switch to the DISABLE
position. See pages 44-45 for more information.
3. System type - Locate the
back of the thermostat. Select either STD (Standard) or HP
(Heat Pump) to match your system.
switch on the back of the