Hunter Fan 42856-01 User Manual

Type A ModelsType A ModelsType A Models
Form# 42856-01 20090130 ©2009 Hunter Fan Co.
For Your Records and Warranty Assistance
For reference, also attach your receipt or a copy of your receipt to the manual.
__________________________________________ Model Name
__________________________________________ Model No.
__________________________________________ Date Purchased
__________________________________________ Where Purchased
English Español
Owner’s Guide and Installation Manual
Vancouver
21321, 21328
2
42856-01 • 01/30/09 • Hunter Fan Company
Table Of Contents
1 • Getting Ready......................4
2 • Installing the Hanger Bracket .......5
3 • Assembling and Hanging the Fan ...6
4 • Wiring the Fan .....................7
5 • Installing the Motor Housing .......8
6 • Assembling the Blades..............9
7 • Completing Your Installation With or
Without a Bowl Light Fixture ......10
8 • Operating and Cleaning Your Ceiling
Fan ...............................14
9 • Troubleshooting....................15
© 2009 Hunter Fan Company
Your new Hunter® ceiling fan is an addition to your home or oce that will provide comfort and performance for many years. is installation and operation manual gives you complete instructions for installing and operating your fan.
We are proud of our work. We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
Before installing your fan, for your records and warranty assistance, record information from the carton and Hunter nameplate label (located on the top of the fan motor housing).
Cautions and Warnings
READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, attach the fan directly to the support structure of the building according to these instructions, and use only the hardware supplied.
• To avoid possible electrical shock, before installing your fan, disconnect the power by turning o the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the o position, securely fasten a prominent warning device, such as a tag, to the service panel.
• All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualied electrician.
• To reduce the risk of personal injury, do not bend the blade attachment system when installing, balancing, or cleaning the fan. Never insert foreign objects between rotating fan blades.
• To reduce the risk of re, electrical shock, or motor damage, do not use a solid-state speed control with this fan. Use only Hunter speed controls.
Welcome
3
42856-01 • 01/30/09 • Hunter Fan Company
Mounting and Optional Accessories
Understanding Mounting
Hunter’s patented mounting system provides you maximum ease in installing your fan. is fan was designed to be mounted only on at ceilings and can be used on ceilings less than 8 feet high.
Considering Optional Accessories
Consider using Hunter’s optional accessories, including a wall-mounted or remote speed control. To install and use the accessories, follow the instructions included with each product. For quiet and optimum performance of your Hunter fan, use only Hunter speed controls.
Low Profile Mounting ts close to the ceiling, recommended for ceilings less than 8 feet high
Support Brace
Low Prole Mounting Style
Ceiling Outlet Box
CAUTION: To reduce the risk of
personal injury, attach the fan directly to the support structure of the building according to these instructions, and use only the hardware supplied.
4
42856-01 • 01/30/09 • Hunter Fan Company
To install a ceiling fan, be sure you can do the following:
• Locate the ceiling joist or other suitable support in ceiling.
• Drill holes for and install wood screws.
• Identify and connect electrical wires.
• Lift 40 pounds.
If you need help installing the fan, your Hunter fan dealer can direct you to a licensed installer or electrician.
Gathering the Tools
You will need the following tools for installing the fan:
• Electric drill with 9/64” bit
• Standard screwdriver (magnetic tip recommended)
• Phillips-head screwdriver (magnetic tip recommended)
• Wrench or pliers
• Ladder (height dependent upon installation site)
Checking Your Fan Parts
Carefully unpack your fan to avoid damage to the fan parts. Refer to the included Parts Guide. Check for any shipping damage to the motor or fan blades. If any parts are missing or damaged, contact your Hunter dealer or call Hunter Technical Support Department at 888-830-1326.
Preparing the Fan Site
Before you begin installing the fan, follow all the instructions in the pullout sheet called “Preparing the Fan Site.” Proper ceiling fan location and attachment to the building structure are essential for safety, reliable operation, maximum eciency, and energy savings.
Installing Multiple Fans?
If you are installing more than one fan, keep the fan blades and blade irons (if applicable) in sets, as they were shipped.
1 • Getting Ready
5
42856-01 • 01/30/09 • Hunter Fan Company
Steps 2-4 – 2-6
CAUTION: To avoid possible electrical shock, before installing your fan,
disconnect the power by turning o the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the o position, securely fasten a prominent warning device, such as a tag, to the service panel.
2-1. Drill two pilot holes into the wood support structure through the
outermost holes in the outlet box. e pilot holes should be 9/64” in diameter.
2-2. Place the trim ring over the ceiling plate.
2-3. read the lead wires from the outlet box down through the hole
in the middle of the ceiling plate.
2-3. Align the slotted holes in the ceiling plate with the pilot holes you
drilled in the wood support structure.
2-4. Place a at washer on each of the two 3” wood screws and pass
the screws through the slotted holes in the ceiling plate into the pilot holes you drilled.
Tighten the screws into the 9/64” pilot holes; do not use lubricants
on the screws. Do not over tighten.
Ceiling
Plate
Flat Washer
3” Wood Screw
2 • Installing the Hanger Bracket