Thank you for choosing a Hunter programmable
thermostat. Your new Hunter thermostat will
provide years of reliable service and year-round
energy savings.
Please read this manual before beginning
installation and save this booklet for complete
operation instructions.
4
IMPORTANT INFORMATION
This thermostat is designed to work on the following
heating and cooling systems:
Gas – Standing Pilot
Gas – Electronic Ignition
Gas – Fired Boilers
Gas – Milivolt Systems
Oil – Fired Boilers
Oil – Fired Furnace
Electric Furnace
Electric Air Conditioning
Single Stage Heat Pump - No auxilary
This thermostat is not designed for multi-stage heat
pump systems or 110/220 V baseboard heating
systems.
If you are unsure what kind of heating and cooling
1. Turn the system power OFF from the existing
thermostat. Turn the power to the HVAC
system OFF at the main power panel or at
the furnace.
2. Remove the existing thermostat cover to
access the wires from the wall.
(Some thermostats may have multiple covers, screws
or other locking devices that must be removed or
disengaged.)
3. Locate, but do not disconnect the wires.
(If wires are not visible, they may be connected to the
back of the wall plate. Some models may have doors
that open to expose the wires and mounting screws.)
9
if your existing thermostat is
marked...
label the wire with this
sticker:
G / F
G
G
W / H / B
W/B
W/B
Y / C* / M / O
Y/0
Y/0
RC / VC
RC
RC
RH / R / VR / 4
RH
RH
24 Volt
24 Volt cool
air conditioning compressor
heating
fan
Y1
Y1
Y1
heat pump compressor
10
UNINSTALLING THE EXISTING UNIT, CONT.
4. Using the provided stickers, label each wire
according to the chart.
(If the terminals are not labeled, contact
a qualied HVAC technician.)
Note: Wire colors do not always comply
W
with standards, so wire color should be
W
G
Y
RC
ignored. Refer to the existing terminal
designation for proper identication.
*If wires marked Y & C are both present, C may
be a Common wire and should not be used. If
you have a wire marked C, do not connect it
to any terminal. This wire is used only for nonbattery powered thermostats.
5. Do not let the wires slip back into the
wall during disconnection. You may want
to secure the wires to the wall as you
disconnect them. After all wires are labeled,
disconnect each wire and remove the
existing wall plate.
11
Y
G
W
RC
12
INSTALLING THE THERMOSTAT
INSTALLING THE WALL PLATE
1. Remove the wall plate from the new
thermostat by pressing the release tab on the
bottom of the thermostat.
2. Position the new wall plate on the wall and
pull the labeled wires through the opening.
3. If the existing holes do not match those
on the Hunter wall plate, or if there are no
existing holes, visually level the wall plate
and mark the wall for two holes.
13
Y
G
W
RC
14
INSTALLING THE THERMOSTAT, CONT.
4. Remove the wall plate and drill two 3/16”
holes where marked.
5. Tap the plastic anchors into the holes until
they are ush with the wall.
6. Reposition the wall plate on the wall, pulling
the wires through the opening. Insert the
mounting screws through the wall plate and
into the anchors. Verify that the wall plate
is visually level and securely tighten both
screws.
15
Y/0
RC
G
Y1
W/B
G
RCRH
Y/0
16
W/B
Y1
Terminal Shield
INSTALLING THE THERMOSTAT, CONT.
CONNECTING THE WIRES
1. Loosen, but do not remove, the terminal
screws.
Note: A jumper wire has been provided,
Jumper
G RC RH YW
place.
connecting the RC and RH terminals for
systems that do not provide both an RH
and RC wire. If you have both an RH and RC
wire, remove this jumper. If you do not have
both an RH and RC wire, leave the jumper in
2. Match and connect the wires from the wall
to the terminals as shown. Wires should be
inserted behind the black terminal shields.
Tighten each screw after the connection has
been made.
(The ends of any extra wires should be wrapped in
electrical tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the
wall to prevent interference.
17
Loading...
+ 38 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.