Hunter Fan 41787-01 User Manual

I n s t a l l a t i o n G u i d e
81004 Ventura Bath Ventilator Fan With Light
41787-01 1/11/2006
READ and SAVE THESE INSTRUCTIONS
W a r n i n g
TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty.
2. Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust­ing of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards,
such as those published by the National Fire Prevention
Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.
7. Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.
8. Install fan at least 5 feet (1.52 m) above the floor.
9. Never place a switch where it can be reached from a tub
or shower.
10. This unit must be grounded.
C a U T i O n
1. For general ventilating use only. Do not use for ventilat­ing hazardous or explosive materials.
2. To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.
4. Please read specification label on product for further information and requirements.
W a r n i n g
DISCONNECT
ELECTRIC
POWER SUPPLY
SERVICE PANEL
BEFORE
SERVICING UNIT
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.
2
41787-01 1/11/2006
x4
3/8" Cable Connector
*
*
*
NOTE:
Strain relief cable connector must be installed. Not Included.
A
B
C
Extra Screws
x2
H
E
D
L
77864-02
F
G
H
I
J
K
03242-07-133
96261-01-000
95047-02-000
74508-03-133
95776-01-000
75184-01-133
96258-01/02/03-008
75171-01/02/03-000
x2
Check all the parts.
x4
3/8" Cable Connector
*
*
*
NOTE:
Strain relief cable connector must be installed. Not Included.
A
B
C
Extra Screws
x2
H
E
D
L
77864-02
F
G
H
I
J
K
03242-07-133
96261-01-000
95047-02-000
74508-03-133
95776-01-000
75184-01-133
96258-01/02/03-008
75171-01/02/03-000
x2
If damaged, call
1-888-830-1326
for replacements.
Included.
Before Installation
Tools Needed. (Not supplied.)
Estimated assembly time: 30 to 60 minutes
NOTE: Remove all packing materials before installation
New construction installation
Go to Existing Construction Installation,
Go to Step A1, page 4
Existing construction
page 8
41787-01 1/11/2006
Turn off the power source.
3
A1
D
A2
A3
A6
F
A4
A5
New Construction Installation
Loosen screw securing motor.
Remove packing material.
Remove the motor/blower from the housing.
Remove the pre-loaded screw tip covers.
Back out the pre-loaded screw tips until flush with the
side of the housing.
4
Remove the wiring cover screw.
41787-01 1/11/2006
A7
E
A8
D
A9
B
C
A10
D
5/8 1/2
5/8 1/2
A11
OPTION
Remove the wiring cover. Pop out the first wiring access slug. Use second if needed.
Insert the strain relief into the housing and secure
Screw pre-loaded screws into joist or framing. Nail the tabs on both sides to joist or framing so that the
41787-01 1/11/2006
with the washer.
Position the correct depth mark at the bottom edge
of the joist–based on the thickness of your sheet rock.
housing will be flush with the finished ceiling.
(Nails are not provided.)
5
0
A16
D
A12
A13
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
A14
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
D
E
A15
F
Pull the wires through the strain relief.
Tighten the strain relief screws.
Connect wires as shown.
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the wiring cover plate.
6
Connect a 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
41787-01 1/11/2006
A22
C1
Go to step
on page 12
to attach grille.
0000
D
A17
G
0000
G
D
A18
A20
ON
OF
F
A21
Connect wiring from the motor to the wiring cover plate.
A19
H
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched between
the motor and the housing.
41787-01 1/11/2006
Secure the motor by tightening the 2 screws.
Test the motor. If the motor does not run,
check the plug connection.
Turn on the power source.
7
B3
7.25 ”
7.75
B1
D
B2
D
Existing Construction Installation
Use the motor housing as a template to mark position.
Existing Fan
Remove the existing fan and check to make sure the
opening is large enough to accommodate the new motor
housing (7.25” x 7.75”).
Cut out an opening for the housing.
Loosen screw securing motor.
8
Remove the motor/blower from the housing.
Remove packing material.
41787-01 1/11/2006
B4
B5
B8
D
B9
B
C
B6
E
B7
E
Remove the pre-loaded screw tip covers.
Back out the pre-loaded screw tips until flush with the
side of the housing.
Remove the wiring cover.Remove the wiring cover screw.
Pop out the first wiring access slug. Use second if needed.
41787-01 1/11/2006
Insert the strain relief into the housing and secure
with the washer.
9
D
B10
B11
2
1
B12
D
B13
D
B14
Move the housing into position above the ceiling.
Pull the wires through the strain relief and tighten the
strain relief screws.
10
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.
Connect the wiring.
Fit housing into the opening and secure by tightening the
pre-loaded screws into the joist.
Note: Install the box flush with the sheetrock (ceiling).
41787-01 1/11/2006
Loading...
+ 22 hidden pages