READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER.
1. This Air Purifier is designed for use on a flat, level surface and
may not work properly on an uneven surface. ALWAYS place
this Air Purifier on a firm, level surface. ALWAYS place the Air
Purifier at least six (6) inches away from walls and heat sources
such as stoves, radiators, or heaters.
2. Place the Air Purifier in an area that is out of the reach of
children.
3. Before using the Air Purifier, extend the cord and inspect for
any signs of damage. If the supply cord is damaged, it must be
replaced by a manufacturer or its service agent or similarly
qualified person in order to avoid hazard.
4. If the plug does not fit fully and securely into the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to use the unit unless the plug fits securely
into the socket.
5. ALWAYS UNPLUG the Air Purifier when it is not in operation,
while the filter is being changed, or while it is being cleaned.
6. DO NOT tilt or move the Air Purifier while it is in operation.
Shut off and unplug before moving.
7. DO NOT immerse the Air Purifier in water, as permanent
damage will occur. Refer to and follow the AIR PURIFIER
MAINTENANCE instructions.
READ AND SAVE ALL INSTRUCTIONS.
241481-01 10-5-2001
Page 3
INTRODUCTION
Thank you for purchasing the QuietFlo™ T rue HEP A Air Purifier from Hunter
Fan Company. You have purchased our latest development in portable
Air Purification Systems. This system has been developed to improve the
quality of the air you breathe.
Our QuietFlo™ True HEPA Air Purifier out performs other air purification
systems by quickly and effectively removing dust, smoke, and pollen
particles. The HEPA filter will remove 99.97% of particles 0.3 microns in
size from air that passes through the filter.
The activated carbon pre-filter helps remove cooking, smoke, and pet
odors from the air. It also traps lint, hair, and large particles, which helps
improve the life and performance of the HEPA filter.
HOW THE QUIETFLO™ HEPA AIR PURIFIER WORKS
As the air is pulled into the purifier , the activated carbon pre-filter absorbs
odors and catches large particles. Then, the air travels through the HEP A
filter where the smaller particles are collected. Finally, the clean purified
air is released back into the room.
®
Figure 1- Illustration of the Air Filtration System
41481-01 10-5-20013
Page 4
441481-01 10-5-2001
Page 5
41481-01 10-5-20015
Page 6
®
641481-01 10-5-2001
Page 7
41481-01 10-5-20017
Page 8
®
To reset the pre-filter or filter counters before the indicators are lit:
In some environments, you may want to change the pre-filter or filter
English
more frequently than indicated by the filter indicators. This procedure
allows you to reset the pre-filter or filter counter before the indicators ar e
lit.
1. Change the filter and/or pre-filter as described in the Maintenance
section of the manual.
2. Now, you must choose which counter you want to reset. Press and
hold the filter reset key (approximately three seconds) until the prefilter indicator flashes. Press and release the reset key again to
alternate between the two indicators. The counter that will be reset
is designated by the flashing indicator.
For Models 36394 and 36395: Use the tip of a pen or pencil to press
the key.
3. Once you have the correct indicator flashing, press and hold the reset
key for three seconds to reset that counter to zero hours. The indicator
will stop flashing when it has been reset. If needed, repeat these
steps to reset the other counter.
AIR PURIFIER MAINTENANCE
CLEANING YOUR AIR PURIFIER
Proper maintenance of your Hunter Air Purifier will help ensure years of
trouble free service. Follow these steps to properly maintain your air
purifier:
1. Approximately every 90 days, the outside of the unit should be cleaned
with a soft, damp cloth.
2. If needed, the front grille can be removed from the unit and cleaned
with soapy water. Simply remove the pre-filter before exposing the
grille to water.
3. Use the following instructions to determine when and how to replace
the filter and pre-filters.
Notes:
· The air purifier should be unplugged during all cleaning processes.
· Be sure the unit is completely dry before plugging in and using.
· Never immerse the unit in water.
841481-01 10-5-2001
Page 9
CHANGING THE PRE-FILTER
In a typical environment, the pre-filter should be changed every 2000
hours (approximately 3 months of use) to maintain proper odor -removing
capability and overall filtration performance. Changing the pre-filter
regularly will also help extend the life of the HEPA filter. If necessary, the
pre-filter can be changed more frequently. The following instructions tell
you how to change the pre-filter.
For Models 36144, 36145, 36259, 36260, 36394, 36395: The pre-filter
indicator will flash after 2000 hours of use as a reminder that you should
change the pre-filter.
1. Turn OFF and unplug the air purifier .
2. Remove the front grille to expose the pre-filter. The pre-filter is
attached to the front grille with hook tape. Pull gently on the prefilter to remove it. Once removed, you can dispose of the used prefilter.
3. If needed, use a soft damp cloth to wipe off the front grille.
4. Remove the new pre-filter from the plastic wrapping and install it in
the grille by pressing gently on the corners where it adheres to the
hook tape. Y ou may notice a few black particles coming off the pr efilter . Those particles ar e part of the odor -removing activated carbon
and will be collected on the filter during normal use. Mark the new
filter installation sticker included with the pre-filter and place the
sticker on the front grille for future reference.
5. Install the front grille onto the unit and plug in the air purifier.
6. For Models 36144, 36145, 36259, 36260, 36394, 36395: Reset the
pre-filter counter as described in the Pre-filter and Filter Counter section
of this manual.
CHANGING THE HEPA FILTER
Although the proper time to change the filter depends on usage and the
environment, a typical life is 8000 hours (approximately 1 year of usage).
If you notice a decrease in air output or an increase in noise at any time
during normal operation, the filter may be clogged and need to be
replaced. A color -coded chart is also included on the inside of the housing
to help you determine if it is time to change the HEP A filter. Follow these
instructions to change the HEPA filter.
For Models 36144, 36145, 36259, 36260, 36394, 36395: The filter
indicator will flash after 8000 hours of use as a reminder that you should
change the filter.
1. Turn OFF and unplug the air purifier .
2. Remove the front grille and gently pull on the filter to remove it from
the unit. While removing the filter, note the direction of the flaps
that form the seal around the filter. The new filter will be installed
41481-01 10-5-20019
®
English
Page 10
1041481-01 10-5-2001
Page 11
®
41481-01 10-5-200111
Page 12
Hunter Fan Company
2500 Frisco Avenue
Memphis, Tennessee 38114
United States of America
http://www.hunterfan.com