Hunter Fan 30770, 30771 User Manual

HEPAtech+UVCHEPAtech+UVCHEPAtech+UVC
Form# 43059-01 20081106 ©2008 Hunter Fan Co.
English
Germicidal Air Purifier
Owner’s Guide
30770 30771
©2008 HUNTER FAN CO. 43059-01 20081106
2
Safety Instructions .........................................................................................3
Introduction ....................................................................................................3
Description of Air Filtration System
How the Air Purifier Works .............................................................................4
Air Purifier Components.................................................................................4
Display and Control Keys ..............................................................................5
Operation
Initial Operation .............................................................................................6
Filter Life Counters ........................................................................................8
Resetting the Air Purifier ................................................................................8
Using the Ionizer............................................................................................8
Air Purifier Maintenance
Cleaning Your Air Purifier...............................................................................9
Changing the Pre-Filter .................................................................................9
Changing the Filter ......................................................................................10
Changing the UVC Lamp.............................................................................11
Obtaining Replacement Filters and UVC Lamps .........................................14
Troubleshooting
Problem and Solutions ................................................................................14
Technical Support ........................................................................................14
Warranty Information ...................................................................................15
Table of Contents
©2008 HUNTER FAN CO. 43059-01 20081106
3
SAFETY INSTRUCTIONS
Thank you for purchasing the HEPAtech+UVC Air Purifier from Hunter Fan Company. You have purchased our latest development in portable air purification which has been designed to improve the quality of the air that you breathe. The following innovative features are included in your Hunter Air Purifier.
• High Particulate Efficiency: The HEPAtech® filter will remove 99.97% of 0.1 micron particles from
the air that passes through the filter.
Odor Removal: The activated carbon Pre-Filter helps remove odors such as cooking, smoke, and
pet smells from the air. It also traps lint, hair, and other large particles to help extend the life and
performance of the HEPAtech® filter.
Ionizer: The ionizer improves the quality of air in the room by releasing negative ions into the air
that attract positively charged dust, smoke, and pollen particles.
UVC Lamp: This Hunter Air Purifier is equipped with a UVC germicidal lamp. UVC technology is a
proven germicide that is accepted by the FDA and EPA as having the ability to kill pathogens in air
that is exposed to UVC light.
Filter Counters: Filter maintenance is critical to the performance of the Air Purifier. To help you
determine when to change the filters, the Pre-Filter and HEPAtech® filter, the unit has built in life
counters that keep track of the life remaining of each filter.
WARNING: This Air Purifier emits UV radiation that may cause eye and/or skin irritation. RG-3.
Avoid exposing eyes and skin to unshielded UVC Lamp.
Caution: The UVC Lamp may shatter and cause injury if it is dropped or sustains impact. Wear safety glasses and gloves when handling the UVC Lamp. Do not use excessive force when handling
the UVC Lamp. Dispose of the UVC bulb in accordance with local or State guidelines as trace amounts of Mercury are present.
IMPORTANT!
READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER.
1. This Air Purifier is designed for use on a flat level floor and may not work properly on an uneven
floor. ALWAYS place the Air Purifier on a firm level floor. ALWAYS place the Air Purifier at least six (6) inches away from walls and heat sources such as stoves, radiators, or heaters.
2. Place the Air Purifier in an area that is out of the reach of children.
3. Before using the Air Purifier, extend the cord and inspect for any signs of damage. DO NOT use
the product if the cord has been damaged.
4. This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug
will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician. DO NOT attempt to defeat or over-
ride this safety feature.
5. ALWAYS UNPLUG the Air Purifier while it is being cleaned.
6. DO NOT move or tilt the Air Purifier while it is in operation. Turn off and unplug before moving.
7. DO NOT immerse the Air Purifier in water at any time because permanent damage will occur. To properly clean your Air Purifier, follow the instructions in the Maintenance section of this manual
(pg. 10).
8. This equipment should be inspected frequently and collected dirt removed from it regularly to
prevent excessive accumulation that could result in flashover or risk of fire.
READ AND SAVE THESE INSTRUCTIONS
!
Description of Air Filtration System
©2008 HUNTER FAN CO. 43059-01 20081106
4
Fig. 1 - Illustration of the Air Filtration System
Fig. 2 - Air Purifier Components
How the HEPAtech+UVC Air Purifier System Works
As the air is pulled into the purifier, the activated carbon Pre-Filter absorbs odors and catches large particles. Then, the air travels through the HEPAtech® filter where the smaller particles are collected. Next, the air passes through the UVC Field, which helps reduce airborne pathogens such as germs, viruses, mold, and mildew. Then, the ionizer releases negative ions into the air that attract positively charged dust, smoke, and pollen particles. Finally, the clean, purified air is released back into the
room.
HEPAtech® Filter
Carbon Pre-Filter
Front Grill
Base
UVC Lamp
UVC Lamp Cover
Dust & Irritants
Pollen & Allergens
Odors
Bacteria
Pet Hair & Dander
Carbon Pre-
Filter
HEPAtech®
Filter
99.97% – .1
Microns
Ionizer
UVC Field
Reduces airborne
pathogens
Airborne Pathogens
(Germs. viruses,
mold, mildew)
Air Purifier Components
Description of Air Filtration System
©2008 HUNTER FAN CO. 43059-01 20081106
5
SPEED KNOB: Adjusts the blower speed and turns the unit on and off.
PRE-FILTER RESET: Resets the Carbon Pre-Filter Life Counter.
FILTER RESET / UVC RESET: Resets the HEPAtech® Filter Life Counter; resets the
UVC Lamp Life Counter.
IONIZER KEY: Turns the Ionizer on and off.
UVC KEY: Turns the UVC on and off.
UVC Key Pre-Filter
Reset Key
Filter Reset
/ UVC Lamp
Reset Key
HEPAtech® Filter Indica­tor
Carbon Pre-Filter Indicator
On / Off
Indicator
Speed Knob
Off
Sleep
Active Turbo
Clean
Ionizer Key
Ionizer Indicator
UVC Lamp Indicator
Fig. 3 - Air Purifier Control Area
Display and Control Keys
Operation
©2008 HUNTER FAN CO. 43059-01 20081106
6
Fig. 4
Fig. 5
Pull Forward,
then up
Handle
Initial Operation
This section provides basic instructions on the use of your Air Purifier. After following these ini-
tial directions, please continue reading this booklet to learn how to operate the more advanced
features of your Air Purifier.
Basic Operation of the Air Purifier:
1. Take the Air Purifier out of the box and remove the clear plastic protective bag. Place the unit
on a firm level floor.
2. Before turning on the unit, you need to confirm that the filters are firmly in place and have not become loose during shipping. To check the filters, first open the Front Grill. Release the Front Grill by placing your fingers under the handle on the Grill and pull forward, then up.
Refer to Figs. 4 and 5.
3. Next, check the HEPAtech® filter by pressing firmly on all four corners of the Filter to ensure that it is fully inserted into the filter opening. NOTE: THIS UNIT WILL NOT OPERATE
UNLESS FILTER IS INSTALLED CORRECTLY AND SEATED PROPERLY.
4.The Carbon Pre-Filter is mounted inside the Front Grill with hook tape. Confirm that it properly covers the Grill vents. You may notice a few black particles coming off the Pre-Filter.
Those particles are part of the odor-removing activated carbon and will be collected on the filter during use.
5. Place the Front Grill back onto the unit. First, line up the tab on the bottom of the Grill with the recess on the Purifier Base and then push the top of the Grill forward until it is closed. Refer to Figs. 6 and 7. NOTE: THIS UNIT WILL NOT OPERATE UNLESS THE FRONT GRILL IS INSTALLED CORRECTLY.
Operation
©2008 HUNTER FAN CO. 43059-01 20081106
7
Fig. 8
OFF sleep active turbo clean
Fig. 6
Fig. 7
purifier base
6. Plug the unit into a 120V electrical outlet and turn the Speed Knob . The unit will start with a low blower speed.
7. Use the Speed Knob to adjust the blower speed to the desired level (Off, Sleep, Active, Turbo Clean). Refer to Fig. 8.
Operation
©2008 HUNTER FAN CO. 43059-01 20081106
8
Filter Type Typical Usage Activated Carbon Pre-Filter 1400 hours HEPAtech® Filter 2800 hours
Filter Life Counters
The Pre-Filter and Filter are critical to the proper operation of the Air Purifier. To help you know
when to change the filters, your Hunter Air Purifier has Filter Life Counters that will monitor the life of your filters. Although the exact life of the filters depends on the environment, the table
below gives typical usage times of the filters.
Table 2: Typical Usage Times of the Filters
The Pre-Filter and Filter indicators will turn on when the filters need to be replaced.
The values of the Pre-Filter and Filter Life Counters are stored in the Air Purifier’s memory. The unit may be unplugged and moved or stored without losing the Pre-Filter and Filter Counter values.
To properly track filter usage, the Pre-Filter and Filter Life Counters should be reset each time
the filters are changed. Refer to Changing the Pre-Filter (pg. 9) or Changing the Filter (pg. 10) for instructions on how to reset the counters.
Resetting the Air Purifier
In the unusual situation that the unit or the display is exhibiting erratic behavior, you may want to reset the Air Purifier. If you still have problems after resetting the Air Purifier, please contact Hunter for additional assistance (refer to Technical Support, pg. 14).
To Reset the Air Purifier:
1. Unplug the unit for at least 30 seconds.
2. Plug the unit back in.
Using the Ionizer
Using the Ionizer improves the quality of air in the room. Negative ions are released into the
air and positively charged dust, smoke, and pollen particles are attracted to the negative
ions. These particles settle out of the air and can be vacuumed up during normal cleaning.
These particles are also more easily captured by the HEPAtech® filter as they pass through the HEPAtech® Air Purification System. To ensure the best air circulation in the room, we recommend that you place your Air Purifier six (6) inches away from any walls.
To turn the Ionizer on or off:
1. To turn the Ionizer on, press the Ionizer key. The Ionizer Indicator will turn on.
2.To turn the Ionizer off, press the Ionizer key. The Ionizer Indicator will turn off.
When the Ionizer is on, the amber LED will remain illuminated.
Air Purifier Maintenance
©2008 HUNTER FAN CO. 43059-01 20081106
9
Cleaning Your Air Purifier
Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service.
Follow these steps to properly maintain your Air Purifier:
1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp
cloth.
2. If needed, the Front Grill can be removed from the unit and cleaned with soapy water. Simply remove the Pre-Filter before exposing the Grill to water.
3. Follow the instructions in Changing the Pre-Filter and Changing the Filter (pgs. 9 and 10) to determine when and how to replace the filters.
NOTES:
• The Air Purifier must be unplugged during the cleaning process.
• Be sure the unit is completely dry before plugging in and using.
• Never immerse unit in water.
Changing the Pre-Filter
When the Pre-Filter exceeds 1400 hours (refer to Filter Life Counters for additional information, pg. 8), the Pre-Filter Indicator will turn on as a reminder that you should replace the Pre-Filter. To maintain proper odor-removing capability and overall filtration performance, the Pre-Filter should be changed every 1400 hours (approximately 3 months of use). If necessary, the Pre­Filter can be changed more often. Proper maintenance of the Pre-Filter will help extend the life of the HEPAtech® filter. Refer to Obtaining Replacement Filters (pg. 14) if you need help finding
replacement filters.
1. First, turn off and unplug the Air Purifier.
2. Next, remove the Front Grill. Place your fingers under the handle on the Grill and pull forward, then up. Refer to Figs. 4 and 5 (pg. 6).
3. The Pre-Filter is attached to the inside of the Grill with hook tape. Pull gently on the Pre-Filter
to remove it. Refer to Fig. 9 (pg. 9)
4. If needed, use a soft damp cloth to wipe off the Grill.
5. Install the new Pre-Filter by placing it in the Grill and pressing gently on the Pre-Filter so that
it adheres to the hook tape. You may notice a few black particles coming off the Pre-Filter. Those particles are part of the odor-removing activated carbon and will be collected on the filter during regular use.
6. Place the Front Grill back onto the unit. First, line up the tab on the bottom of the Grill with the recess on the purifier base and then push the top of the Grill forward until it is closed. Refer to Figs. 6 and 7 (pg. 7). NOTE: This unit will not operate unless the Grill is in the correct
position.
7. Plug in the Air Purifier.
8. To reset the counter to zero hours and turn off the indicator, simply press and
hold
the Pre-Filter reset key for three seconds. Then, you must release the reset key and
then press and hold the Pre-Filter reset key again for three seconds to turn off the filter indicator.
To change the Pre-Filter and reset the Pre-Filter Life Counter:
Air Purifier Maintenance
©2008 HUNTER FAN CO. 43059-01 20081106
10
Changing the Filter
When the filter exceeds 2800 hours (approximately 4 to 6 months of use), the Filter indicator
will turn on as a reminder that you should replace the filter. (Refer to Filter Life Counters for
additional information, pg. 8.) This is a reminder that you should check the Filter and replace if
necessary. The proper time to change the Filter depends on usage and the environment. Use
the following list to help determine if the filter should be changed:
• Compare the color of the Filter to the color coded chart on the inside of the housing. If the Filter color matches the darkest color on the chart, you should replace the Filter.
• If you notice a decrease in air output or an increase in noise at any time during normal operation, the Filter may be clogged. Replace the Filter to return to normal operation.
To change the Filter and reset the Filter Life Counter:
1. First, turn off and unplug the Air Purifier.
2. Next, remove the Front Grill. Place your fingers under the handle on the Grill and pull forward, then up. Refer to Figs. 4 and 5 (pg. 6).
3. Gently pull on the Filter to remove it from the unit. While removing the Filter, note the
directional arrows printed on the top of the Filter. The new Filter will be installed with the
same orientation. Refer to Fig. 10. Once removed, the used Filter can be discarded.
4. Look at the directional arrows printed on the side of the Filter. Install the Filter with arrows pointing towards the unit. Refer to Fig. 10. Press the Filter firmly into the Air Purifier. To avoid
damaging the Filter media, you should press on the frame of the Filter only. NOTE: THIS
UNIT WILL NOT OPERATE UNLESS FILTER IS INSTALLED CORRECTLY AND SEATED PROPERLY.
5. Place the Front Grill back onto the unit. First, line up the tab on the bottom of the Grill with the recess on the purifier base and then push the top of the Grill forward until it is closed. Refer to Figs. 6 and 7, pg. 7. NOTE: This unit will not operate unless the Grill is in the correct
position.
6. Plug in the unit.
7. To reset the counter to zero hours and turn off the indicator, simply press and hold the Filter Reset key for three seconds. Then, you must release the Filter
Reset key and then press and hold the Filter Reset key again for three seconds to turn off the Filter Indicator.
Fig. 9
Pre-Filter
Hook Tape
Filter
Fig. 10
Loading...
+ 22 hidden pages