Hunter Fan 28983, 28407, 28408, 28984, 28345 User Manual

...
INSTALLATION INSTRUCTIONS FOR HUNTER
Fan Spe ed Swit ch
Capa citor
Re verse Sw itch
M ulti-w ire Plu g Connection
Capa citor
Be ll mou th Nut
M 3 Hou sing Assem bly Screw s
Lig ht K it Lead Wires an d W ire Nuts
CEILING FAN LIGHT KITS M ODELS:
28330, 28331, 28332, 28333, 28334, 28335, 28336, 28337, 28338, 28339, 28340, 28341, 28342 28343, 28344, 28345, 28405, 28406, 28407, 28408, 28982, 28983, 28984, 28985, 28986, 28987
CAUTIONS
Read entire text carefully before beginning in­stallation and save these instructions.
To reduce the risk of electrical shock, install this light kit only on listed Hunter ceiling fan models: C ote D’ Azur, Custom Home 2 , Captiva, 44” Dominion, Designer’s C hoice, ORBit, 52” Dominion, M arseille, Santa Barbara, Belle Meade & Etruscan
WARNING
To avoid possible electrical shock, before in­stalling light fixtures, disconnect power by turning off the circuit breakers both to the outlet box and to its associated wall switch location. If you cannot lock the circuit break­ers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
Connect house wiring to the fan before at­taching the light fixture to the fan.
All wiring must be in accordance with na­tional and local electrical codes and ANSI/ NFPA 70. If you are unfamiliar with wiring, you should use a qualified electrician.
FIGURE 1
4. Locate and carefully remove the two capacitors from the switch housing.
5. You have now disconnected the wiring harness and its components from the switch housing and are ready to install them into the modular acces­sory light kit.
STEP 2: INSTALLING W IRING HARNESS
STEP 1: REMOVING WIRING HARNESS
Before you can install the modular accessory light kit, you must remove the wiring harness and its com­ponents from the modular switch housing on the fans listed above. You must then install the wiring harness into the modular accessory light kit.
NOTE: Refer to Figure 1 for the steps listed below.
1. Locate the reversing switch and carefully remove the two screws holding the reversing switch to the switch housing. The reversing switch can now be removed from the switch housing.
2. Remove the patented breakaway connector from the fan pull chain.
3. Carefully loosen the bellmouth nut from the fan pull chain and remove the fan pull chain switch from the switch housing.
NOTE: Refer to Figure 1 for steps listed below.
1. Locate the two wires in the lower switch housing labeled “ C onnect Light Here” or “ For Light Use” . One will be white, the other black/white. Unscrew the wire nuts counterclockw ise to expose the bare metal leads.
2. Locate the white wire and the black wire coming from the light fixture.
Connect the black wire from the light fixture to the black/white wire from the lower switch hous­ing.
Connect the white wire from the light fixture to the white wire from the lower switch housing.
To fasten the wires, twist the two bare leads to­gether. Place a wire nut over the intertwined length of wire and twist clockwise until tight.
41 490-01 12/01/2005
W ires to Light So ck ets
Be llm outh Nut
Light Switch
Capacitor
M u lti-wir e Plug Connectio n
Reverse Switch
Be llm outh Nut
Fan Speed Switch
Capacitor
#6-62 H ousin g Assembly Screw s
FIGURE 2
CAUTION
Be sure no bare wire or wire strands are visible after making connections.
3. Insert the chain and fan pull chain switch through the round opening on the side of the modular accessory light kit. Thread the bellmouth nut over the pull chain and hand tighten the bellmouth nut.
4. Reattach the patented breakaway connector to the end of the pull chain.
5. Insert the reversing switch into the square hole on the side of the modular accessory light kit. Install and tighten the two screws you removed in Step 1, substep 1.
6. Carefully place the capacitors in the modular ac­cessory light kit.
You have completed the assembly of the modular accessory light kit and are ready for installing the modular accessory light kit to the fan.
UPPER SW IT CH HO USIN G
LOW ER PLU G CO NNE CT O R
HO USIN G ASSEM BLY SCREW
UP PER PLU G CO NNE CT O R
LIG HT KIT
FIGURE 3
2. Place the modular accessory light kit over the up­per switch housing. Align the side screw holes in the upper sw itch housing and the modular acces­sory light kit. Attach the modular accessory light kit to the upper switch housing with the three #6-32 X 3/8" housing assembly screws.
STEP 4: INSTALLING THE BULBS AND GLOBES
NOTE: Refer to Figure 4 for the steps listed below.
1. Insert a globe into the cup.
2. Tighten the thumbscrews manually. Do Not overtighten.
3. Repeat substeps 1 and 2 for the remaining three globes.
4. Install a 60W medium base incandescent bulb into each socket.
You have completed the installation of the modular accessory light kit. Refer back to the “ Operating Your Hunter Fan” section in the Installation/Owner’s Manual provided with your Hunter fan for proper operation instructions.
STEP 3: INSTALLING THE ACCESSORY LIGHT KIT
NOTE: Refer to Figure 3 for the steps listed below.
1. C onnect the lower (mutli-wire) plug connector from the modular accessory light kit to the up­per plug connector from the motor.
NOTE: Both plug connectors are polarized and w ill only fit together one way. M ake sure that both connectors are properly aligned before connect­ing them together. Incorrect connection could cause improper operation and damage to the product.
CUP
GLOBE
FIGURE 4
Hunter Fan C ompany 2500 Frisco Avenue Memphis, TN 38114 USA
TH UM B­SCREW S
© 2005 Hunter Fan Co.
41 490-01 12/01/20 05