Hunter Fan 28341, 28406, 28407, 28405, 28340 User Manual

...
INSTALLATION INSTRUCTIONS FOR HUNTER
CEILING FAN LIGHT KITS MODELS:
28330, 28331, 28332, 28333, 28334, 28335, 28336, 28337, 28338, 28339, 28340, 28341, 28342 28343, 28344, 28345, 28405, 28406, 28407, 28408, 28982, 28983, 28984, 28985, 28986, 28987
CAUTIONS
Read entire text carefully before beginning in-
stallation and save these instructions.
To reduce the risk of electrical shock, install
this light kit only on Hunter ceiling fan models with removable switch housings.
W ARNING
To avoid possible electrical shock, before in­stalling light xtur es, disconnect power by turning of f the cir cuit breakers both to the outlet box and to its associated wall switch location. If you cannot lock the cir cuit break­ers in the of f position, secur ely fasten a prominent war ning device, such as a tag, to the service panel.
Connect house wiring to the fan befor e at-
taching the light xtur e to the fan.
All wiring must be in accor dance with na-
tional and local electrical codes and ANSI/ NFPA 70. If you ar e unfamiliar with wiring, you should use a qualied electrician.
Light Kit Lead Wires and Wire Connectors
Bellmouth Nut
Fan Speed Switch
Capacitor
Multi-wire Plug Connection
M3 Housing Assembly Screws
Reverse Switch
Capacitor
FIGURE 1
4. Locate and car efully remove the two capacitors from the switch housing.
5. You have now disconnected the wiring har ness and its components fr om the switch housing and are ready to install them into the modular acces­sory light kit.
STEP 1: REMOVING WIRING HARNESS
Before you can install the modular accessory light kit, you must remove the wiring har ness and its com­ponents from the modular switch housing on the fans listed above. You must then install the wiring harness into the modular accessory light kit.
NOTE: Refer to Figure 1 for the steps listed below.
1. Locate the reversing switch and car efully remove the two screws holding the reversing switch to the switch housing. The r eversing switch can now be removed from the switch housing.
2. Remove the patented breakaway connector from the fan pull chain.
3. Carefully loosen the bellmouth nut fr om the fan pull chain and remove the fan pull chain switch from the switch housing.
STEP 2: INSTALLING WIRING HARNESS
NOTE: Refer to Figure 1 for steps listed below.
1. Locate the two wir es in the lower switch housing labeled “Connect Light Here” or “For Light Use”. One will be white, the other black with a white stripe. Unscew the wire connectors counterclockwise to expose the bare metal leads.
2. Locate the white wire and the black wire coming from the light xtur e.
Connect the black wir e fr om the light xture to the black wire with a white stripe from the lower switch housing.
Connect the white wire fr om the light xture to the white wir e from the lower switch housing.
To fasten the wir es, twist the two bare leads to­gether. Place a wire connector over the intertwined
length of wire and twist clockwise until tight.
41490-01 03/12/2009
Wires to Light Sockets
Bellmouth Nut
Light Switch
Capacitor
Multi-wire Plug Connection
Reverse Switch
Bellmouth Nut
Fan Speed Switch
Capacitor
#6-62 Housing Assembly Screws
FIGURE 2
CAUTION
Be sure no bare wire or wire strands are visible after making connections.
3. Insert the chain and fan pull chain switch thr ough the round opening on the side of the modular accessory light kit. Thr ead the bellmouth nut over the pull chain and hand-tighten the bellmouth nut.
4. Reattach the patented breakaway connector to the end of the pull chain.
5. Insert the r eversing switch into the square hole on the side of the modular accessory light kit. Install and tighten the two scr ews you r emoved in Step 1, substep 1.
6. Carefully place the capacitors in the modular ac­cessory light kit.
You have completed the assembly of the modular accessory light kit and are ready for installing the modular accessory light kit to the fan.
UPPER SWITCH HOUSING
LOWER PLUG CONNECTOR
HOUSING ASSEMBL Y SCREW
UPPER PLUG CONNECTOR
LIGHT KIT
FIGURE 3
2. Place the modular accessory light kit over the up­per switch housing. Align the side scr ew holes in the upper switch housing and the modular acces­sory light kit. Attach the modular accessory light kit to the upper switch housing with the three #6-32 X 3/8" housing assembly screws.
STEP 4: INSTALLING THE BULBS AND GLOBES
NOTE: Refer to Figur e 4 for the steps listed below.
1. Insert a globe into the cup.
2. Tighten the thumbscr ews manually. Do Not overtighten.
3. Repeat substeps 1 and 2 for the remaining three globes.
4. Install a 13W CFL bulb into
You have completed the installation of the modular accessory light kit. Refer back to the “Operating and cleaning your ceiling Your Hunter Fan” section in the Owner’s Manual provided with your Hunter fan for proper operation instructions.
each socket.
STEP 3: INST ALLING THE ACCESSOR Y LIGHT KIT
NOTE: Refer to Figure 3 for the steps listed below.
1. Connect the lower (mutli-wire) plug connector from the modular accessory light kit to the up­per plug connector fr om the motor.
NOTE: Both plug connectors ar e polarized and will only t together one way . Make sur e that both connectors are properly aligned befor e connect­ing them together. Incorr ect connection could cause improper operation and damage to the product.
CUP
GLOBE
FIGURE 4
Hunter Fan Company 7130 Goodlett Farms Pkwy. Memphis, TN 38016 USA
© 2009 Hunter Fan Co.
41490-01 03/12/2009
THUMB­SCREWS
Loading...