INSTALLATION INSTRUCTIONS FOR HUNTER
CEILING FAN LIGHT KITS MODELS:
28330, 28331, 28332, 28333, 28334, 28335, 28336, 28337, 28338, 28339, 28340, 28341, 28342
28343, 28344, 28345, 28405, 28406, 28407, 28408, 28982, 28983, 28984, 28985, 28986, 28987
CAUTIONS
Read entire text carefully before beginning in-
stallation and save these instructions.
To reduce the risk of electrical shock, install
this light kit only on Hunter ceiling fan
models with removable switch housings.
W ARNING
• To avoid possible electrical shock, before installing light xtur es, disconnect power by
turning of f the cir cuit breakers both to the
outlet box and to its associated wall switch
location. If you cannot lock the cir cuit breakers in the of f position, secur ely fasten a
prominent war ning device, such as a tag, to
the service panel.
Connect house wiring to the fan befor e at-
taching the light xtur e to the fan.
All wiring must be in accor dance with na-
tional and local electrical codes and ANSI/
NFPA 70. If you ar e unfamiliar with wiring,
you should use a qualied electrician.
Light Kit Lead Wires
and Wire Connectors
Bellmouth Nut
Fan Speed
Switch
Capacitor
Multi-wire Plug
Connection
M3 Housing
Assembly Screws
Reverse Switch
Capacitor
FIGURE 1
4. Locate and car efully remove the two capacitors
from the switch housing.
5. You have now disconnected the wiring har ness
and its components fr om the switch housing and
are ready to install them into the modular accessory light kit.
STEP 1: REMOVING WIRING HARNESS
Before you can install the modular accessory light
kit, you must remove the wiring har ness and its components from the modular switch housing on the
fans listed above. You must then install the wiring
harness into the modular accessory light kit.
NOTE: Refer to Figure 1 for the steps listed below.
1. Locate the reversing switch and car efully remove
the two screws holding the reversing switch to
the switch housing. The r eversing switch can now
be removed from the switch housing.
2. Remove the patented breakaway connector from
the fan pull chain.
3. Carefully loosen the bellmouth nut fr om the fan
pull chain and remove the fan pull chain switch
from the switch housing.
STEP 2: INSTALLING WIRING HARNESS
NOTE: Refer to Figure 1 for steps listed below.
1. Locate the two wir es in the lower switch housing
labeled “Connect Light Here” or “For Light Use”.
One will be white, the other black with a white stripe.
Unscew the wire connectors counterclockwise
to expose the bare metal leads.
2. Locate the white wire and the black wire coming
from the light xtur e.
Connect the black wir e fr om the light xture to
the black wire with a white stripe from the
lower switch housing.
Connect the white wire fr om the light xture to
the white wir e from the lower switch housing.
To fasten the wir es, twist the two bare leads together. Place a wire connector over the intertwined
length of wire and twist clockwise until tight.
41490-01 03/12/2009
Wires to Light Sockets
Bellmouth Nut
Light Switch
Capacitor
Multi-wire Plug
Connection
Reverse Switch
Bellmouth Nut
Fan Speed
Switch
Capacitor
#6-62 Housing
Assembly Screws
FIGURE 2
CAUTION
Be sure no bare wire or wire strands are visible after
making connections.
3. Insert the chain and fan pull chain switch thr ough
the round opening on the side of the modular
accessory light kit. Thr ead the bellmouth nut over
the pull chain and hand-tighten the bellmouth
nut.
4. Reattach the patented breakaway connector to
the end of the pull chain.
5. Insert the r eversing switch into the square hole
on the side of the modular accessory light kit.
Install and tighten the two scr ews you r emoved
in Step 1, substep 1.
6. Carefully place the capacitors in the modular accessory light kit.
You have completed the assembly of the modular
accessory light kit and are ready for installing the
modular accessory light kit to the fan.
UPPER SWITCH
HOUSING
LOWER PLUG
CONNECTOR
HOUSING ASSEMBL Y
SCREW
UPPER PLUG
CONNECTOR
LIGHT KIT
FIGURE 3
2. Place the modular accessory light kit over the upper switch housing. Align the side scr ew holes in
the upper switch housing and the modular accessory light kit. Attach the modular accessory light
kit to the upper switch housing with the three
#6-32 X 3/8" housing assembly screws.
STEP 4: INSTALLING THE BULBS AND
GLOBES
NOTE: Refer to Figur e 4 for the steps listed below.
1. Insert a globe into the cup.
2. Tighten the thumbscr ews manually. Do Not
overtighten.
3. Repeat substeps 1 and 2 for the remaining three
globes.
4. Install a 13W CFL bulb into
You have completed the installation of the modular
accessory light kit. Refer back to the “Operating
and cleaning your ceiling Your Hunter Fan” section in the
Owner’s Manual provided with your Hunter fan for
proper operation instructions.
each socket.
STEP 3: INST ALLING THE ACCESSOR Y
LIGHT KIT
NOTE: Refer to Figure 3 for the steps listed below.
1. Connect the lower (mutli-wire) plug connector
from the modular accessory light kit to the upper plug connector fr om the motor.
NOTE: Both plug connectors ar e polarized and will
only t together one way . Make sur e that both
connectors are properly aligned befor e connecting them together. Incorr ect connection could
cause improper operation and damage to the
product.
CUP
GLOBE
FIGURE 4
Hunter Fan Company
7130 Goodlett Farms Pkwy.
Memphis, TN 38016
USA
© 2009 Hunter Fan Co.
41490-01 03/12/2009
THUMBSCREWS