Congratulations on purchasing your new Hunter® ceiling fan! It will provide comfort and
performance in your home or ofce for many
years. This installation and operation manual contains complete instructions for installing and operating your fan.
We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
Canopy
Blades Troubleshooting
What to Expect with
Your Installation
2
Blade Irons
6
Bulbs & Globe
Tools Needed
PAG E
Light Kit
PAG E
Remote & Cradle
3
7
Mounting Options
PAG E
PAG E
Maintenance
& Cleaning
4
9
Ceiling Bracket
PAG E
PAG E
?
PAG E
5
WiringDownrod
PAG E
12
?
14
PAG E
15
PAG E
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
16
PAG E
PAG E
17
1
PAG E
20
?
www.HunterFan.com
PAG E
21
What to Expect with Your Installation
If you are unfamiliar with wiring, use a
qualied electrician.
Must be able to secure the fan to building structure or fan-rated outlet box
You may need a friend to help you.
Check box to see fan weight
Know your wiring
Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.
Assess ceiling angle
76.2 cm / 30 in.
from blade tip to nearest wall or obstruction
2.1 m / 7 ft.
from bottom
edge of blade
to the oor
Assess location
Standard Downrod
(included, pre-assembled)
1
for ceilings 2.4–3 meters / 8–10 feet high
Shorter Downrod
2
(included) for fans installed close to ceiling
Longer Downrod
(sold separately)
3
for ceilings 3 meters / 10 feet or higher
Select a downrod length
2
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
Monday - Friday 8am - 6pm CST
Saturday 11am - 4pm CST
(English or Español)
1.888.830.1326
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or personal injury, mount
fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets
when installing the blade brackets, balancing the blades, or cleaning the
fan. Do not insert foreign objects in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and local electrical
codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualied
electrician. c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: modications not approved by the party responsible for
compliance could void user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
www.HunterFan.com
Tools Needed
Monday - Friday 8am - 6pm CST
Saturday 11am - 4pm CST
(English or Español)
1.888.830.1326
Ladder
Screwdrivers
Pliers Wire Strippers
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
9/64” Drill Bit
(optional)
3
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
Do not discard the hardware bags or mix
parts from different bags. Make note of
the symbol printed on each hardware
bag. The symbols can be used to identify
the appropriate hardware for each step.
www.HunterFan.com
O
34
CEILING
Mounting Options
Monday - Friday 8am - 6pm CST
Saturday 11am - 4pm CST
(English or Español)
1.888.830.1326
OPTION
If you have a at ceiling:
WALL
Hang your fan by a standard downrod (included).
Standard Mounting
1
Support Structure
Support Structure
OPTION
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
Use the three steps below to determine if your ceiling angle is greater than 34°
Angled Mounting
2
Standard Mounting Style
Ceiling
Outlet Box
(required)
Angled Mounting Style
Ceiling
Outlet Box
(required)
FOLD
on dotted line
1
N
O
I
T
A
U
T
I
S
1
34°
Guide Touches
BOTH Ceiling & Wall
You need ONLY
a Longer
Downrod
*most common
2 3
PLACE
against wall
2
N
O
I
T
A
U
T
I
S
Guide Touches
but NOT Ceiling
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
SLIDE
toward ceiling
Wall
to hang the fan from a at ceiling.
4
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
Use Standard Mounting
or Low-Prole Mounting
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
www.HunterFan.com
Ceiling Bracket
Turn Power
OFF
For angled ceilings, point
opening toward peak.
Monday - Friday 8am - 6pm CST
Saturday 11am - 4pm CST
(English or Español)
1.888.830.1326
Make sure all four bumpers are
still attached.
Refer to warning w.1 on pg. 2
If you are unable to do this,
call Technical Support at
1-888-830-1326.
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
Use wood screws (included) when securing to support structure with approved electrical outlet
box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket
with hardware found in
the hardware bag.
5
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet
box associated with the wall switch location.
www.HunterFan.com
Blade Irons
Monday - Friday 8am - 6pm CST
Saturday 11am - 4pm CST
(English or Español)
1.888.830.1326
Turn the motor assembly upside down and
place it in one of the holes in the packaging.
Install a blade iron to the blade iron mounting
plate using two blade iron assembly screws,
found in the hardware bag. Repeat this
process to install all ve blade irons.
6
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
www.HunterFan.com
Light Kit
Light Kit
Assembly
Screw
Monday - Friday 8am - 6pm CST
Saturday 11am - 4pm CST
(English or Español)
1.888.830.1326
Partially install two light kit assembly
screws, found in the hardware bag,
halfway into the motor housing as
shown. It does not matter which two
screw holes you choose.
Feed the 9-pin plug connector coming from
the bottom of the motor housing through
the center hole in the light kit assembly.
Connect it to the plug connector found
in the switch housing area of the light kit
assembly. Make sure to line up the colored
markings on the connectors.
7
M3633-01 • 01/03/17 • © 2017 Hunter Fan Company
Align the keyhole slots in the top of
the light kit assembly with the partially
installed assembly screws. Wrap the
keyhole slots around the screws and
twist counterclockwise.
www.HunterFan.com
Loading...