Hunter ICR Owners And Installation Manual

ICR
Institutional Commercial Remote
For Use with Hunter Controllers
Owner’s Manual and Installation Instructions
ENGLISH/ESPAÑOL
®
®
OFF ON
MODE
TABLE OF CONTENTS .....................................................................................
Introduction .................................................................................................................................................................. 1
ICR Components
........................................................................................................................................................... 2
SmartPort® Wiring Harness ............................................................................................................................................ 4
Installing the SmartPort
®
Wiring Harness ....................................................................................................................... 4
Wiring the SmartPort
®
to Hunter Controllers................................................................................................................... 5
Typical Installations
....................................................................................................................................................... 6
Preparing the Transmitter for Use
................................................................................................................................... 6
Installing the Transmitter Battery
................................................................................................................................... 7
Changing the Run Time
.................................................................................................................................................. 7
Changing the Transmitter Address
.................................................................................................................................. 8
Changing the Maximum Station Number
......................................................................................................................... 8
Preparing the Receiver for Use
....................................................................................................................................... 9
Changing the Receiver Address
...................................................................................................................................... 9
Activating a Station with the ICR
.................................................................................................................................. 10
Maximizing Operating Range
........................................................................................................................................ 11
Troubleshooting Guide
................................................................................................................................................. 12
Specifications .............................................................................................................................................................. 13
TABLA DE CONTENIDO ...................................................................................
Presentación del Producto ........................................................................................................................................... 15
Componentes del ICR
.................................................................................................................................................. 16
Conexión de Cableado del Programador SmartPort
®
...................................................................................................... 18
Instalación del Arnés de Cableado SmartPort
................................................................................................................ 18
Conexión de Cableado del Programador SmartPort
®
.......................................................................................................
19
Instalaciones Típicas ................................................................................................................................................... 20
Preparación del Emisor Antes de su Uso
....................................................................................................................... 20
Colocación de la Pila del Emisor
................................................................................................................................... 21
Cambio del Tiempo del Ciclo de Riego
.......................................................................................................................... 21
Modificación de la Dirección del Emisor
....................................................................................................................... 22
Modificación del Número Máximo de Estaciones
........................................................................................................... 22
Preparación del Receptor Antes de su Uso
................................................................................................................... 23
Modificación de la Dirección del Receptor
.................................................................................................................... 23
Activación de una Estación por Medio del Sistema de Mando a Distancia ICR
................................................................. 24
Optimización de la Zona de Funcionamiento
.................................................................................................................. 25
Guía Para Solucionar Problemas
.................................................................................................................................. 26
Datos Técnicos
............................................................................................................................................................ 27
1
INTRODUCTION ...............................................................................................
Finally there’s an affordable remote control system designed with the commercial irrigation contractor in mind. Hunter is pleased to introduce the Institutional Commercial Remote (ICR). This rugged remote design offers similar functionality as our SRR remote, but with longer range capability.
With the ICR there’s no need to walk back and forth to the controller to conduct manual watering operations when doing maintenance or repair work on your irrigation systems. Also, winterization can be done quickly and easily with one worker instead of two.
The ICR is designed to be rugged, and water resistant. Its large LCD display and push button design makes it easy to operate. Best of all, with an operating range from ½ to 1 mile, you’ll be able to conduct remote operations on even the
largest irrigation systems.
The following instructions provide information on installing, setting up, and operating your ICR.
2
ICR COMPONENTS .............................................................................................
ICR
OFF ON
MODE
®
A
2
3
4
1
B D
C
5
7
8
6
9
3
B – Receiver
7. Receiver Body – Rugged, water resistant design.
8.
Addressing Button – Allows for easy receiver to transmitter addressing.
9.
External Antennae – Flexible, removable antennae for maximum range.
C – SmartPort
®
D – Carrying Case
This section will provide a brief overview of some of the components on the ICR. Each item will be discussed in further detail later, however, this section can be helpful in getting acquainted with the different options available.
A – Transmitter
1. Transmitter Body – The ICR transmitter is designed to
be dirt tolerant and water resistant.
2.
LCD Display – Large, easy to read LCD display.
3.
Control Buttons – Push button operation.
4.
External Antennae – Flexible, removable rubber for maximum radio range.
5.
Battery Compartment – The ICR is designed to operate on a four AA alkaline batteries. The batteries easily drop into a battery holder.
6.
Belt Clip – Belt clip provides convenient access to the transmitter at all times.
4
To utilize the ICR remote control system, your controller must be equipped with a SmartPort wiring harness. This wiring harness provides the communication port where the ICR receiver is attached. The SmartPort can be connected to Hunter SRC, Pro-C and ICC controllers. A SmartPort wiring
harness is provided with your ICR remote system. The typical SmartPort location is approximately 12" below the controller. The recommended installation procedure for this location would be as follows:
SmartPort® WIRING HARNESS .......................................................................
INSTALLING THE SmartPort
WIRING HARNESS ........................................
1. Install a ½" female threaded “Tee” in the field wiring
conduit approximately 12" below the controller.
2. Feed the red, white, and blue wires of the SmartPort through the base of the “Tee” and into the controller wiring compartment as shown in the following figures.
NOTE: The harness may be installed outdoors by bringing the conduit through an exterior wall, then installing the appropriate fitting.
NOTE: For installations where the receiver will be installed permanently on an outside wall, make certain that the SmartPort is the version with an o-ring seal.
1
/2" Thread
To Controller
Pre-assembled Assembled
5
SRC Controller SmartPort Installation
Access the terminal strip area and attach the red wire to the left
AC screw slot, attach the white wire to the next AC screw
slot and attach the blue wire to the screw slot marked “
R”.
Pro-C Controller SmartPort Installation
Access the terminal strip area on the main module and attach the red wire to the bottom most
AC screw slot, attach
the white wire to the upper
AC screw
slot and attach the blue wire to the screw slot marked “
REM”.
ICC Controller SmartPort Installation
Access the terminal strip area on the power module and attach the red wire to the bottom most
AC screw slot,
attach the white wire to the upper
AC screw
slot and attach the blue wire to the screw slot marked “
REM”.
WIRING THE SmartPort® TO HUNTER CONTROLLERS ..............................
NOTE: Hunter ACC controllers are provided with the SmartPort® Factory installed.
Red
Blue
White
Blue White Red
AC AC R RS C MV 1 2 3 4 5 6
White
Blue
Red
6
Although the ICR Receiver is water resistant, it is recommended that the SmartPort® connector and Receiver be mounted indoors if it is to be left per
-
manently mounted to the controller.
TYPICAL INSTALLATIONS ................................................................................
The ICR remote system is designed to work right out of the box. This means that other than installing the battery, you may choose to skip this entire section. However, we recommend that you read it so that you can customize your ICR to add functionality and security to your system.
PREPARING THE TRANSMITTER FOR USE .................................................
Controller
Receiver
Outdoor Installation (Temporary Connection of Receiver Only)
Indoor Installation
Loading...
+ 22 hidden pages