Hunter 99134, 99135, 99136, 99138, 99140 User Manual

1.888.830.1326
Traditional
3-Light Fitter
Models 99134, 99135, 99136, 99138, 99140
Compatible with:
2xxxx Types A - Z
51000-58999 fan series 59500-59999 fan series Select Casablanca Fans
Switch Housing
Connector
Wire
START
HERE
Read entire installation instructions
carefully before beginning installation
and save these instructions.
Turn Power
OFF
Cap Screw
WHICH ASSEMBLY
METHOD WILL I USE?
If your fan’s switch housing cap resembles this one, remove the cap screws with a Phillips head
screwdriver. Then follow the
instructions for TYPE-A ASSEMBLY.
Switch
Housing
Cap
OR OR
Switch Housing Screw
If your fan’s switch housing cap
resembles this one, remove the
whole switch housing by removing
the switch housing screws with a
Phillips head screwdriver. Remove
the plug button. Then follow the
TYPE-B ASSEMBLY INSTRUCTIONS.
GO TO
NEXT PAGE
Plug
Button
Switch Housing Assembly Screw
If your fan’s switch housing cap
resembles this one, remove the whole
switch housing by removing the switch
housing screws with a Phillips head
screwdriver. Remove the two cap screws
from the inside of the switch housing.
Reinstall the switch housing. Tighten the switch housing screws. Then follow the instructions for TYPE-A ASSEMBLY.
Switch
Housing
Cap
TYPE-A ASSEMBLY
If your fan does not have pin connectors on the
wires coming from the switch housing, install
the wiring harness provided. Using the provided
wire connectors connect the white wire from
and connect the black or blue wire from the fan
to the black wire from the wire harness.
Switch Housing
TYPE-B ASSEMBLY
If your fan does not have pin connectors on the
wires coming from the switch housing, install
the wiring harness provided. Using the provided
wire connectors connect the white wire from
and connect the black or blue wire from the fan
to the black wire from the wire harness.
Wire
Connector
Using the single pin connectors, connect the
black or blue wire from the fan to the black
wire from the light kit. Connect the white
wire from the fan to the white wire from the
light kit.
Note: Do not allow the light kit to hang only
by the wire connectors.
Light Kit Screw
Feed the light kit wires through the center hole
in the switch housing. Then attach the switch
housing to the light kit by installing the light kit
screws into the bottom of the switch housing.
Lift the light kit up to meet the lower switch
housing. Guide the two pre-installed light
kit screws into the holes in the lower switch
housing. Tighten screws.
Using the single pin connectors, connect the
black or blue wire from the fan to the black
wire from the light kit. Connect the white
wire from the fan to the white wire from the
light kit.
Note: Do not allow the light kit to hang only
by the wire connectors.
GO TO
NEXT PAGE
Switch Housing
Assembly Screw
Lift the light kit up to meet the upper
switch housing. Install the switch housing
assembly screws. Tighten screws.
Improper installation could cause the light xture to
fall, or result in electrical shock or personal injury.
MA015-01 • 12/31/13
Thumb Screw
Shade
(not included)
FOR BOTH ASSEMBLIES
Installing the shades - To install the
shade, rst loosen the thumb screws.
Raise the shade to the light xture.
Tighten all thumbscrews securely.
Installing the bulb - Install a bulb into each
socket. When necessary, replace bulbs with
bulbs of same type and wattage.
Installing the pull chain pendant -
Attach the pull chain pendant to the
end of the short chains coming from the
switch housing and the light kit.
Turn Power
ON
1.888.830.1326
Pull Chain Pendant
To turn lights on and off, pull the pull
chain pendant coming from the center
of the light kit.
ONE YEAR WARRANTY
This product is warranted to the original purchaser by Casablanca
Fan Company/Hunter Fan Company against defects in material and
workmanship for one (1) year from date of purchase. During the warranty period, we will repair or, at our option, replace a defective product at no charge. For information on how to obtain service,
contact the Casablanca/Hunter Service Department by calling our toll-free number at 888-830-1326. Damage to the product caused by mishandling, improper installation or modication is not covered
by this warranty. This warranty is given in lieu of all other warranties
expressed or implied. Some states do not allow limitations of time
on an implied warranty, therefore the above limitations may not
apply in every case. This warranty states specic legal rights which
may vary from state to state.
TROUBLESHOOTING
Lights don’t come on.
Make sure that the bulbs are properly installed.
Make sure power switch is on.
Pull the pull chain to make sure it is on.
Check the circuit breaker to ensure the power is turned on.
Check the pin connections in the light kit.
Refer to the fan manual for locating the fan’s wiring. Verify that the
light and power wires are correctly connected to the ceiling and the light kit.
If you have problems installing or operating your light kit, do not return this product to the dealer. Call our Consumer Affairs Hotline.
888-830-1326
READ AND SAVE THESE INSTRUCTIONS
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs. (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and
associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTIONS
c.1 - All wiring must be in accordance with national and local electrical codes ANSI/ NFPA 70. If you are unfamiliar with wiring, use a qualied electrician.