Hunter 59048 52 User Manual

Table of Contents
30 inches
7 feet
Ladder
www.HunterFan.com
1.888.830.1326
Congratulations on purchasing your new Hunter® ceiling fan! It will provide comfort and performance
in your home or ofce for many
years. This installation and operation manual contains complete instructions for installing and operating your fan.
We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
Blades
What to Expect with
Your Installation
2
Assembling the Top
Housing
6
Light Kit
Tools Needed
PAG E
PAG E
Remote Control
Mounting Options
PAG E
3
Downrod Canopy
PAG E
Wiring
7
Operation,
PAG E
4
PAG E
10
Ceiling Bracket
Troubleshooting
?
PAG E
5
PAG E
11
?
12
13
PAG E
PAG E
17
18
PAG E
?
PAG E
20
PAG E
1
M3534-01 • 05/14/14 • © Hunter Fan Company
What to Expect with Your Installation
If you are unfamiliar with wiring, use a
qualied electrician.
Must be able to secure the fan to building structure or fan-rated outlet box
You may need a friend to help you.
Know your wiring
30 inches
from blade tip to nearest wall or obstruction
from bottom
edge of blade
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
7 feet
to the oor
www.HunterFan.com
1.888.830.1326
1.888.830.13261.888.830.1326
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or personal
injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage, use only Hunter Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
CAUTIONS
Check box to see fan weight
Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.
Assess ceiling angle
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
2
M3534-01 • 05/14/14 • © Hunter Fan Company
c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring,
use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications.
Tools Needed
www.HunterFan.com
1.888.830.1326
Ladder
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
Pliers Wire Strippers
9/64” Drill Bit
(optional)
M3534-01 • 05/14/14 • © Hunter Fan Company
Screwdrivers
If you are installing multiple remote-controlled
fans on the same circuit breaker,
you may need to perform a few extra steps to
prevent interference or faulty operation of your
remote controls.
Go to www.HunterFan.com/FAQs and click “How do I properly install multiple remote-
controlled fans?” for more information.
3
O
34
CEILING
Mounting Options
www.HunterFan.com
www.HunterFan.com
1.888.830.1326
1.866.268.1936
OPTION
If you have a at ceiling:
WALL
Hang your fan by a standard downrod (included).
Standard Mounting
1
Support Structure
Support Structure
OPTION
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
Use the three steps below to determine if your ceiling angle is greater than 34°
Angled Mounting
2
Standard Mounting Style
Ceiling
Outlet Box
(required)
Angled Mounting Style
Ceiling
Outlet Box
(required)
FOLD
on dotted line
1
N
O
I
T
A
U
T
I
S
1
34°
Guide Touches
BOTH Ceiling & Wall
You need ONLY
a Longer
Downrod
*most common
2 3
PLACE
against wall
2
N
O
I
T
A
U
T
I
S
Guide Touches
but NOT Ceiling
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
SLIDE
toward ceiling
Wall
4
4
M3534-01 • 05/14/14 • © Hunter Fan Company
M3534-01 • 05/14/14 • © Hunter Fan Company
Use Standard Mounting
or Low-Prole Mounting
to hang the fan from a at ceiling.
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
Ceiling Bracket
Turn Power
OFF
For angled ceilings, point
opening toward peak.
www.HunterFan.com
1.888.830.1326
Make sure all four bumpers are
still attached.
Refer to warning w.1 on pg. 2
If you are unable to do this,
call Technical Support at
1-888-830-1326.
M3534-01 • 05/14/14 • © Hunter Fan Company
Use wood screws (included) when securing to support structure with approved electrical outlet
box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket
with hardware found in
the hardware bag.
5
5
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet
box associated with the wall switch location.
Assembling the Top Housing
KEEP!
E
E
P
K
!
Upper Motor
Cover Screw
www.HunterFan.com
1.888.830.1326
Remove the pre-installed
setscrew so that the downrod
can be inserted.
To assemble the housing to the
hanger adapter, align the three
raised tabs on the hanger adapter
with the three narrow notches in
the top housing. Make certain the
housing sits at on the adapter.
M3534-01 • 05/14/14 • © Hunter Fan Company
Install three upper motor cover
screws, found in the hardware
bag, and tighten them securely.
6
Downrod
www.HunterFan.com
www.HunterFan.com
1.888.830.1326
1.888.830.1326
Standard Downrod
for ceilings 8-10’ high
Option 1
Shorter Downrod
for fans installed close to ceiling
Option 2
Included
(pre-assembled)
Longer Downrod
for angled ceilings or
Option 3
ceilings 10’ or higher
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
1 2 3 4 5
Slide
Slide
678910
Included
Sold Separately
Steps 6-10 to reassemble with new pipe
7
M3534-01 • 05/14/14 • © Hunter Fan Company
Downrod (continued)
www.HunterFan.com
www.HunterFan.com
1.888.830.1326
1.888.830.1326
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
3/8”
T
U
C
P
I
R
T
S
&
8”
(not to scale)
The wires can be cut, but leave at least 8”
extending from the top of the downrod.
8”
8
8
M3534-01 • 05/14/14 • © Hunter Fan Company
Tighten the setscrew with pliers.
DO NOT HAND TIGHTEN.
3/8”
If the setscrew is not tightened securely, the fan may fall.
Downrod (continued)
DO NOT PICK THE FAN UP BY THE
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
www.HunterFan.com
1.888.830.1326
of the fan.
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
9
M3534-01 • 05/14/14 • © Hunter Fan Company
Wiring
F
A
M
N
O
R
F
Using an orange wire
connector from the hardware bag, connect the
3 grounding wires
(green, green/yellow
stripe, or bare copper)
coming from the
ceiling, downrod, and
hanging bracket.
M
O
R
F
stripe (grounding)
green/yellow stripe
stripe
F
R
O
M
C
E
I
L
Note: To connect the
www.HunterFan.com
1.888.830.1326
wires, hold the bare
metal leads together and
E
C
I
L
I
N
G
place a wire connector
over them, then twist
E
C
R
E
I
M
O
R
F
V
E
R
E
C
I
L
M
I
O
R
F
N
G
clockwise until tight.
green/yellow
Using the orange
wire connectors
from the remote
control hardware bag, connect the blue wire from the receiver
green/yellow
to the blue wire (or possibly black with
white stripe wire) from
the fan. Connect the yellow wire from the receiver to the black
wire from the fan.
T
E
K
C
A
R
B
I
G
N
yellow
black
F
blue
Using the orange wire
connectors from
black
(ungrounded)
white (grounded)
F
A
M
N
O
R
F
the hardware bag,
connect the black wire
(ungrounded) from
white
the ceiling to the black
blue
wire from the receiver.
Connect the white
black
white
wire (grounded) from
the ceiling to both the
white wire from the
receiver and the white
wire from the fan.
F
R
R
N
O
A
F
M
O
M
R
R
E
V
I
E
C
E
Refer to CAUTION c.1 on pg. 2
Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
10
M3534-01 • 05/14/14 • © Hunter Fan Company
Canopy
Screw
Holes
www.HunterFan.com
1.888.830.1326
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Lift the canopy into place so that
the screw holes are aligned.
M3534-01 • 05/14/14 • © Hunter Fan Company
Insert the two canopy screws
found in the hardware bag.
Note: Fan style may vary.
11
Blades
Holes
www.HunterFan.com
1.888.830.1326
Insert blade into slot. Align the holes on the
blade with the holes in the fan motor.
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the nishes.
Attach the blade to the motor using the at
washers from the hardware bag and blade
assembly screws found in the hardware
bag. Repeat for each blade.
12
M3534-01 • 05/14/14 • © Hunter Fan Company
Light Kit
Attachment Screw
www.HunterFan.com
1.888.830.1326
Partially install two attachment
screws, found in the hardware
bag, into the light kit mounting plate.
Thread the 9-pin plug connector from the
fan through the light kit.
13
M3534-01 • 05/14/14 • © Hunter Fan Company
Align the keyholes in the light kit with the two
partially installed screws and turn the light kit
clockwise until the screws are in the narrow
ends of the keyholes.
Light Kit (continued)
Attachment Screw
Wire Slot
www.HunterFan.com
1.888.830.1326
Install the remaining attachment screw
to secure the light kit to the mounting
plate. Securely tighten all three screws.
Make sure the light kit is securely attached to the mounting plate. Failure to properly secure all three assembly screws
could result in the light xture falling.
Thread the 2-pin connector through the wire
slot in the the switch housing.
14
M3534-01 • 05/14/14 • © Hunter Fan Company
Connect the upper 9-pin plug connector
from the fan to the lower 9-pin plug
connector in the light kit.
Light Kit (continued)
www.HunterFan.com
1.888.830.1326
Align the two screw screw holes and
install the switch housing assembly
screws, found in the hardware bag.
Wire Slot
Connect the the 2-pin plugs from the
switch housing and the LED assembly.
Push excess wiring into the switch
housing through the wire slot.
15
M3534-01 • 05/14/14 • © Hunter Fan Company
Light
Assembly
Screw
Attach the LED assembly to the
switch housing by installing two
light assembly screws, found in the
hardware bag, through the slots, not
the screw holes.
Light Kit (continued)
Glass Globe
Globe
Assembly
Screw
Trim Ring
www.HunterFan.com
CONGRATULATIONS!
YOU’RE DONE!
1.888.830.1326
Place the glass globe into the globe trim
ring. Align the three holes in the trim
ring with the three holes in the light
kit. Install and securely tighten all three
globe assembly screws, found in the
hardware bag.
M3534-01 • 05/14/14 • © Hunter Fan Company
See next page for fan operation instructions.
16
Remote Control
If you are installing multiple remote-controlled fans on the same circuit breaker, you may need to perform a few
extra steps to prevent interference or faulty operation of
your remote controls.
Go to www.HunterFan.com/FAQs and click
“How do I properly install multiple remote-controlled fans?”
for more information.
www.HunterFan.com
1.888.830.1326
Battery Door
Phillips Head Screw
To access the battery compartment, remove the small Phillips head screw that secures the battery door to the transmitter assembly. The
battery should be installed with the positive
(+) side up. Replace with a CR2032 battery
when necessary.
Turn Power
ON
17
17
M3534-01 • 05/14/14 • © Hunter Fan Company
Fan Off
High
Note: The remote must be paired before
the fan will operate.
Within 3 minutes of restoring power to
the fan, press both the Fan Off button and
the High button for at least 4 seconds. Your
fan will turn on low to indicate successful syncing. If it does not, turn off power to your fan, wait 1 minute then try again. If using the
transmitter with multiple fans, repeat this
process for each fan.
Operation, Maintenance, & Cleaning
Medium
Speed
Fan Off
High
Speed
Switch Cover Plate
www.HunterFan.com
1.888.830.1326
Low
Light
Speed
To turn on fan, press a fan speed button. Speeds
range from off (0) to high (3). Quickly press the
Light button to turn the lights off and on.
Hold the Light button to raise and dim the
light level.
Removed Tabs
To install the transmitter cradle, remove the
two screws holding the switch cover plate. Do
not remove the cover plate. Orient the cradle
by lining up the two mounting holes with
those on the cover plate. Insert and tighten
the screws. Do not over tighten.
Note: For rocker-style cover plates, break off
the tabs by pushing outward.
Rocker- Style
Plate
18
M3534-01 • 05/14/14 • © Hunter Fan Company
Reverse Switch
To switch the direction of air ow, remove the globe on the fan by removing the globe
assembly screws, the glass, and trim ring. Flip
the black switch to change the direction.
Operation, Maintenance, & Cleaning (continued)
Screw
www.HunterFan.com
1.888.830.1326
Safe-Exit
The Safe-Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the lights go out. To use Safe-Exit:
• Press the Fan Off button for at least three seconds to initiate the Safe-Exit Mode.
The lights will ash for visual
conrmation.
• The lights will stay on 50% brightness for 15 seconds and then begin to dim. After a total of 30 seconds, the lights will be completely off.
To change the bulbs, use a Phillips Head
screwdriver to remove the screws that
secure the LED light ring to the lower
switch housing. Replace with a Hunter
approved replacement LED light ring.
Reinstall the globe assembly.
When cleaning the fan, use soft brushes
or cloths to prevent scratching. Cleaning
products may damage the nishes.
19
M3534-01 • 05/14/14 • © Hunter Fan Company
Troubleshooting
www.HunterFan.com
1.888.830.1326
Fan doesn’t work
• Make sure power switch is on.
• Push the motor reversing switch
rmly left or right to ensure that
it is engaged.
• Check the circuit breaker to ensure the power is turned on.
• Make sure the blades spin freely.
• Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram on page 10.
• Check the plug connection in the switch housing.
Remote control of fan is erratic
• Make sure the battery is installed correctly.
• Install a fresh battery.
Transmitter only works when held at close range
• Install a fresh battery.
Excessive wobbling
• Tighten all of the blade and blade iron screws until they are snug.
• Use the provided balancing kit and instructions to balance the fan.
Noisy Operation
• Tighten the blade and blade
iron screws until they are snug.
• Check to see if any of the
blades are cracked. If so, replace all of the blades.
If you have multiple remotes or multiple remote-controlled fans installed on the same circuit breaker and you are experiencing
interference or faulty operation of your remote controls, please go to www.HunterFan.com/FAQs and click “How do I properly install multiple remote-controlled fans?” for information on how to correct this issue.
Hunter fans have the power to cut your cooling costs up to 40%.
Beat the High Cost of Cooling
The air movement created by a Hunter ceiling fan lets you set your thermostat higher and still stay comfortable. Every degree you raise the thermostat saves up to 7% on energy costs. So, you can cut back on expensive air conditioning ... and save up to 40%* on cooling. In winter, your Hunter fan recirculates warm air and saves up to 10%* on heating bills. * On average at low speed settings. Your savings may vary based on climate, building type and thermostat setting.
Save Energy and Money While Protecting the Environment
Congratulations! You’re saving energy and money while protecting the environment by purchasing this ENERGY
STAR qualied Hunter ceiling fan! With this purchase, you
are doing your part to protect the environment. Your new ceiling fan has earned the ENERGY STAR label
because it meets high energy efciency specications
set by the Environmental Protection Agency (EPA). ENERGY STAR labeled ceiling fans save energy because
they have more efcient fan motors and air delivery due to more aerodynamic blade congurations. Ceiling fan
models bearing the ENERGY STAR label move air 14 -
20% more efciently than typical ceiling fan models.
For more information on ENERGY STAR visit www.energystar.gov.
20
M3534-01 • 05/14/14 • © Hunter Fan Company
Loading...