Must be able to
secure the fan to
building structure or
fan-rated outlet box
You may need a
friend to help you.
Check box to see
fan weight
If you are unfamiliar
with wiring, use a
qualied electrician.
Know your wiring
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
Assess ceiling angle
30 inches
from blade tip
to nearest wall
or obstruction
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
7 feet
from bottom
edge of blade
to the oor
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building
structure and/or an outlet box marked acceptable for
fan support of 70 lbs (31.8 kg) and use the mounting
screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing
or servicing your fan, disconnect the power by turning
off the circuit breakers to the outlet box and associated
wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent
warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor
damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the
blade brackets when installing the blade brackets, balancing
the blades, or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and
local electrical codes ANSI/NFPA 70. If you are unfamiliar
with wiring, use a qualied electrician.
and the blue wires from the
fan. Connect the white wire
(grounded) from the ceiling to
T
E
K
C
A
R
B
G
the white wire from the fan.
F
R
O
N
A
F
M
connect the white wire
(grounded) from the
ceiling to the white wire
from the fan.
Connect the black wire
(ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
Refer to CAUTION c.1 on pg. 2
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
Note: In compliance with US federal energy regulations, this ceiling fan
contains a device that restricts its light output. Exceeding the wattage
limit marked on the MAX wattage sticker afxed to the light socket(s)
may result in re hazard or improper operation.
Installation Without a Light Kit
You must remove the wiring harness and its components from the
integrated light xture. You must then install the wiring harness into the
empty switch housing included with the fan.
• Locate the reversing switch and carefully remove the two screws holding
the reversing switch to the lower switch housing. Now, remove the
reversing switch from the housing.
• Remove the patented breakaway connector from the end of the fan pull
chain. Carefully loosen the bellmouth nut from the pull chain and remove
the pull chain switch from the light xture housing.
• Locate and carefully remove the two capacitors.
• Unplug the two-wire connectors; one connector will have a black with
white stripe wire and a white wire coming from the multi-wire connector.
You have now disconnected the wiring harness and its components and
are ready to install them into the empty switch housing. (The light switch
remains in the light assembly housing.)
• Insert the pull chain and fan pull chain switch through the round
opening on the side of the empty switch housing. Thread the bellmouth
nut over the pull chain and hand tighten the bellmouth nut.
• Reattach the breakaway connector to the pull chain.
• Insert the reversing switch into the square hole on the side of the switch
housing. Install and tighten the two screws you removed previously from
the other switch housing.
• Carefully place the capacitors in the switch housing.